INA2126E/2K5 - Dual 36V Precision INA | Texas Instruments
MPN: INA2126E/2K5 ✓ Hoạt độngINA2126E/2K5 Tóm tắt
An instrumentation amplifier is a specialized differential amplifier that combines high input impedance, accurate differential gain, and strong common-mode rejection in one signal-chain block. Within the amplifier hierarchy, the INA2126 belongs to the precision instrumentation amplifier family, which sits above general-purpose operational amplifiers as a solution for measuring small signals riding on large common-mode voltages. Its internal two-operational-amplifier architecture supports differential sensing without requiring a separate precision input stage.
Key electrical characteristics include a 250 uV offset specification, 0.04 V/us slew rate, 200 kHz bandwidth, and dual-supply operation from approximately -18 V to +18 V. The low 175 uA per-channel quiescent current supports battery-powered and energy-limited instrumentation. The 16-pin SSOP package provides a compact surface-mount footprint, while the dual-channel configuration allows two bridge or shunt measurements in one device.
The two-op-amp internal design provides good performance for low-frequency differential acquisition while maintaining low quiescent current. With a 2500 gain setting, the part is intended for millivolt-level outputs from strain gauges, RTDs, thermocouple interfaces, and high-side current shunts. Bandwidth limits the rise time of fast transients, so applications requiring kilohertz-class signal capture should account for the 200 kHz small-signal bandwidth during filter and sampling design.
Typical uses include portable data loggers, battery-powered sensor interfaces, industrial bridge transmitters, laboratory measurement equipment, and isolated monitoring modules. Differential inputs reduce sensitivity to ground bounce and common-mode noise, while the low quiescent current extends operating time in field-deployed instruments.
When laying out the circuit, keep input and reference pins close to the signal source, use a low-noise reference network, and avoid long parallel traces between the differential inputs. Because the gain is high, input bias current and offset errors become proportionally more significant, making source-impedance balancing and clean grounding important.
This page combines the manufacturer's device specifications with practical placement guidance, comparison parameters, and application-focused design notes. It helps engineers evaluate the INA2126E/2K5 against other INA2126 ordering options before committing the 16-pin SSOP footprint to a PCB layout.
Bộ thay thế dễ dàng lắp đặt cho INA2126E/2K5 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA2126E/2K5 (cùng hình factor và footprint) — khác nhau ở Gain, Package, Quiescent Current.
INA2126E/250
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA2126EA/2K5
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA2126EA/250
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA2126U/2K5
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA2126E/2K5 Tỷ lệ tối đa & tính chất điện
| Amplifier Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 channels |
| Maximum Supply Voltage | 36 V |
| Dual-Supply Operating Range | -18 V to +18 V |
| Minimum Single-Supply Voltage | 1.35 V |
| Điện áp yên tĩnh | 175 uA per channel |
| Input Offset Voltage | 250 uV |
| Gain | 2500 V/V |
| Small-Signal Bandwidth | 200 kHz |
| Slew Rate | 0.04 V/us |
| Hộp | 16-pin SSOP, 150 mil body |
| Kiểu lắp đặt | Surface mount |
| Architecture | Two-operational-amplifier instrumentation amplifier |
| Trạng thái RoHS | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | not_applicable |
Hướng dẫn cấu hình chân INA2126E/2K5 16-pin ssop, 150 mil body
Cấu hình chân cho INA2126E/2K5 (16-pin ssop, 150 mil body gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA2126E/2K5.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA2126E/2K5 phù hợp cho 6 Áp dụngs: Strain-Gauge and Load-Cell Bridge Acquisition, Battery-Powered Data Logging, High-Side Current-Shunt Measurement, Portable Laboratory Instrument Front End, RTD and Resistive Sensor Interface, Industrial Condition-Monitoring Interface.
Strain-Gauge and Load-Cell Bridge Acquisition
The INA2126E/2K5 suits load cells and resistive strain gauges because its fixed gain of 2500 raises a small millivolt bridge imbalance to a level suitable for an ADC. Its 250 uV offset specification and 200 kHz bandwidth support slow mechanical measurements, while the 175 uA per-channel quiescent current helps portable test systems conserve power. Place the amplifier close to the bridge, balance the two input source resistances, and treat the offset and drift as primary calibration terms because both are amplified by the 2500 gain ratio.
Được đề xuất
Battery-Powered Data Logging
The INA2126E/2K5 is appropriate for portable loggers that combine low signal levels with strict energy budgets. Its 175 uA per-channel quiescent current, 1.35 V minimum single-supply capability, and 36 V maximum supply rating allow the same family concept to cover low-energy sensors and higher-voltage industrial inputs. Because instrumentation-amplifier bias current creates error against high source impedance, use low-leakage protection resistors and verify the actual sensor impedance before selecting the device for duty-cycled field measurements.
Được đề xuất
High-Side Current-Shunt Measurement
The INA2126E/2K5 can measure the differential voltage produced by a current shunt when the shunt signal is small enough to remain within the amplifier output range at 2500 V/V. Differential input architecture rejects the supply rail common to the shunt, helping isolate the measurement from load-step noise. Confirm output swing for the expected shunt current and include the amplifier offset, input bias error, and ADC reference error in the current-calculation budget.
Được đề xuất
Portable Laboratory Instrument Front End
The INA2126E/2K5 provides a compact differential input stage for portable laboratory meters that measure small voltages, thermocouple junctions, or resistive bridges. The dual architecture measures two channels in one 16-pin SSOP, helping conserve board area while maintaining a common gain setting. Its 200 kHz bandwidth is appropriate for quasi-static measurements rather than high-speed transients, and the reference network should use low-temperature-coefficient components to prevent gain errors from obscuring the specified 250 uV input offset.
Được đề xuất
RTD and Resistive Sensor Interface
The INA2126E/2K5 can serve as the differential input amplifier in RTD, thermistor, and resistive-sensor interfaces when the sensor excitation is configured for a small differential imbalance. Its high fixed gain reduces the amount of analog gain required downstream, while the dual channel supports redundant or complementary sensing. Care is required because 2500 V/V can limit usable output swing and amplify leakage through protection resistors, so select excitation current and reference components with both signal range and thermal drift in mind.
Được đề xuất
Industrial Condition-Monitoring Interface
The INA2126E/2K5 is useful in industrial monitoring modules that acquire low-level vibration, pressure, or position-sensor outputs in an electrically noisy enclosure. Differential sensing rejects much of the common-mode noise present on long sensor wiring, and the low 175 uA per-channel quiescent current is helpful in distributed, remotely powered nodes. Place the inputs near the connector or sensor to minimize exposed trace area, provide input protection against industrial transients, and confirm that protection leakage remains small relative to the amplified offset error.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho INA2126E/2K5 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | INA2126E/250 | INA2126EA/2K5 | INA2126EA/250 | INA2126U/2K5 |
|---|---|---|---|---|---|
| Package | 16-pin SSOP | 16-pin SSOP - same family footprint | 16-pin SSOP - same family footprint | 16-pin SSOP - same family footprint | 16-pin SSOP - same family footprint |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Fixed Gain | 2500 V/V | 25 V/V | 2500 V/V | 25 V/V | 2500 V/V |
| Number of Channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Maximum Supply Voltage | 36 V | 36 V | 36 V | 36 V | 36 V |
| Quiescent Current | 175 uA per channel | 175 uA per channel | 175 uA per channel | 175 uA per channel | 175 uA per channel |
| Input Offset Voltage | 250 uV | 250 uV | 250 uV | 250 uV | 250 uV |
| Small-Signal Bandwidth | 200 kHz | 200 kHz | 200 kHz | 200 kHz | 200 kHz |
| Slew Rate | 0.04 V/us | 0.04 V/us | 0.04 V/us | 0.04 V/us | 0.04 V/us |
| Supply Configuration | Dual and single supply capable | Dual and single supply capable | Different supply-configuration suffix | Different supply-configuration suffix | Unipolar supply configuration |
Bảo phân biệt quan trọng
- Fixed 2500 V/V gain supports direct measurement of millivolt-level sensor outputs (vsINA2126E/250)
- Dual precision channels in one compact package (vsINA2126EA/2K5)
- Low quiescent current supports portable acquisition (vsINA2126U/2K5)
Ghi chú thiết kế
Route the two differential inputs as a compact, closely coupled pair and keep them away from switching nodes and high-current return paths. The two input source impedances should be closely matched because imbalance converts bias-current error into differential offset. Place input protection components close to the package pins, and use low-leakage protection resistors because the 2500 gain multiplies their contribution to input error.
Check output swing before selecting the 2500 gain setting. A bridge imbalance or shunt voltage that is small at the sensor may become large after multiplication by 2500 and clip the amplifier or the following ADC input. The 200 kHz bandwidth also limits transient response. Derive the maximum expected differential signal, add the reference and offset contributions, and confirm that the complete output range remains inside both device limits.
Use a low-temperature-coefficient reference network and short reference traces, since reference error contributes directly to gain error. For bridge excitation, keep the excitation return and amplifier ground in a controlled relationship so their currents do not flow through sensitive input paths. A differential input filter should be applied symmetrically when practical, preserving the balance between the positive and negative input networks.
Thông tin tuân thủ
The INA2126 is a general-purpose precision instrumentation amplifier rather than an AEC-Q100 automotive-qualified device. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation from the current manufacturer product documentation or supplier declarations.