INA333SKGD1 - 50uA Zero-Drift Instrumentation Amp | TI
MPN: INA333SKGD1 ✓ Hoạt độngINA333SKGD1 Tóm tắt
An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal three-op-amp topology provides high input impedance, symmetric differential inputs, and adjustable gain without disturbing source impedance balance. Within the broader semiconductor hierarchy, it is a linear amplifier, analog IC, and signal-conditioning component used between sensors and ADCs.
Key characteristics include an offset voltage as low as 25 uV at 25 degrees C for gains of 100 or greater, offset drift of 0.2 uV/degree C at gains of 100 or greater, and common-mode rejection of 100 dB at gains of 10 or greater. The gain equation is G = 1 + 100 kOhm divided by RG, allowing gains from 1 to 1000. A 0.16 V/us slew rate supports rapidly changing sensor waveforms without requiring the operating current of a high-power amplifier.
The zero-drift architecture uses autocalibration techniques to reduce input-referred offset over time and temperature. This makes the device useful in battery-powered industrial sensors, portable medical equipment, and low-frequency precision measurement systems. The rail-to-rail output stage improves output-voltage range, while the low 50 uA supply current suits energy-limited equipment. Care is still required near the positive supply rail because output swing and common-mode range depend on supply voltage and load.
Typical uses include strain-gauge bridge excitation, current shunt measurement, pressure and temperature sensing, biomedical instrumentation, and low-level differential ADC front ends. For bridge circuits, the instrument amplifier rejects common-mode voltage and preserves sensor balance. For current measurement, its high input impedance minimizes loading of the shunt and minimizes errors from unequal input impedance.
For reliable operation, place the gain resistor close to RG, maintain symmetric input routing, and use low-noise supply and reference circuitry. Decouple each supply connection locally and verify input common-mode voltage and output swing against the actual supply limits. Use the manufacturer pin-description and die-layout information when assigning connections on the bare die.
This product page combines manufacturer specifications, engineering application guidance, practical design considerations, lifecycle information, and a transparent assessment of replacement options. It also distinguishes the bare-die INA333SKGD1 from packaged INA333 variants so engineers can assess footprint and assembly implications before committing a design.
Bộ thay thế dễ dàng lắp đặt cho INA333SKGD1 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Không có bộ thay thế dễ dàng lắp đặt sẵn có cho sản phẩm này.
Yêu cầu các bộ thay thếINA333SKGD1 Tỷ lệ tối đa & tính chất điện
| Amplifier Type | Precision instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Architecture | 3-operational-amplifier instrumentation amplifier |
| Supply Voltage Range | 1.8 V to 5.5 V |
| Minimum Supply Voltage | 1.8 V |
| Điện áp yên tĩnh | 50 uA |
| Gain Range | 1 to 1000 |
| Gain Equation | G = 1 + (100 kOhm / RG) |
| Offset Voltage | 25 uV at 25 degrees C, gain >= 100 |
| Offset Voltage Drift | 0.2 uV/degree C, gain >= 100 |
| Common-Mode Rejection | 100 dB at 25 degrees C, gain >= 10 |
| Slew Rate | 0.16 V/us |
| Kiểu đầu ra | Rail-to-rail output |
| Khoảng nhiệt độ hoạt động | -40 degrees C to +125 degrees C |
| Hộp | Bare die with 9 terminals |
| Terminal Count | 9 terminals |
| Kiểu lắp đặt | Die |
| Temperature Grade | Military |
| Packaging | Tube |
| Zero-Drift Technology | Autocalibration |
Hướng dẫn cấu hình chân INA333SKGD1 bare die with 9 terminals
Cấu hình chân cho INA333SKGD1 (bare die with 9 terminals gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA333SKGD1.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA333SKGD1 phù hợp cho 6 Áp dụngs: Strain-Gauge Bridge Measurement, Portable Biopotential Instrumentation, Precision Shunt Current Sensing, Low-Power Industrial Sensor Node, Battery-Powered Pressure Transmitter, Precision Data-Acquisition Front End.
Strain-Gauge Bridge Measurement
The INA333SKGD1 is well suited to conditioning resistive strain-gauge bridges because its differential input architecture rejects the large common-mode voltage present at a bridge output. The 100 dB common-mode rejection at gain of at least 10 helps preserve small strain signals, while the 0.2 uV/degree C offset drift at gain of at least 100 supports stable measurements over changing temperatures. A single RG resistor sets the gain according to G = 1 + (100 kOhm divided by RG). Place the bridge excitation and return paths symmetrically, route the two inputs as a balanced pair, and position the gain network close to the device. The 50 uA quiescent current also helps suit compact, battery-powered force or displacement instruments.
Được đề xuất
Portable Biopotential Instrumentation
INA333SKGD1 can serve as the input stage for low-level biopotential measurement when low supply current and precision offset performance are required. Its 50 uA quiescent current is suitable for compact battery-powered equipment, and the zero-drift architecture reduces input-referred offset drift to 0.2 uV/degree C at gain of at least 100. The instrument amplifier’s high differential input impedance reduces loading of the electrode interface. Protection networks, electrode bias components, and patient-safety isolation requirements remain separate from the amplifier’s electrical role. Validate the complete front end against motion artifact, electrode offsets, input bias behavior, and the applicable medical-device safety requirements.
Được đề xuất
Precision Shunt Current Sensing
The INA333SKGD1 is appropriate for measuring a small voltage across a current shunt when the measurement includes a substantial common-mode voltage. Its differential input arrangement and 100 dB common-mode rejection at gain of at least 10 reduce errors that would otherwise corrupt the shunt signal. The rail-to-rail output improves utilization of a low-voltage supply, while 50 uA supply current supports portable battery-operated meters. Select RG to obtain the required shunt gain and check that input and output remain inside the common-mode and swing limits at maximum current. A Kelvin connection from the shunt and symmetric routing of the differential pair are important for repeatable measurements.
Được đề xuất
Low-Power Industrial Sensor Node
INA333SKGD1 fits distributed industrial sensors where a 1.8 V minimum supply and 50 uA quiescent current help extend operating life. It can amplify pressure, temperature, and position sensor outputs before conversion by a low-power ADC. The zero-drift architecture improves long-duration measurement stability, while a gain of up to 1000 allows small sensor outputs to use more of the ADC input range. A practical design should evaluate sensor current in addition to amplifier current, provide local supply bypassing, and avoid placing high-gain traces next to switching or digital timing signals. The manufacturer’s recommended RG and bypass-capacitor values should be used as the starting point for qualification testing.
Được đề xuất
Battery-Powered Pressure Transmitter
INA333SKGD1 can amplify the differential output of a bridge-based pressure sensor in a compact transmitter powered from a low-voltage battery. Its 50 uA quiescent current reduces standby demand, and the 25 uV offset specification at gain of at least 100 helps resolve small pressure-induced bridge voltages. The 1.8 V minimum supply supports compatibility with low-energy sensor and ADC platforms. Set the gain with RG and confirm that the selected supply permits the required output range. Environmental error from temperature drift, excitation variation, and sensor self-heating must be evaluated separately. Place the amplifier close to the sensor or ADC to minimize sensitive-signal trace length and exposure to noisy switching nodes.
Được đề xuất
Precision Data-Acquisition Front End
INA333SKGD1 provides a low-noise differential input stage for a compact laboratory or industrial data-acquisition system. Its 100 dB common-mode rejection at gain of at least 10 helps suppress supply and ground disturbances before the signal reaches an ADC, while the 0.16 V/us slew rate supports waveforms beyond static sensor conditions. Use RG to establish the required input range and confirm that the ADC’s sampling architecture does not require a different bandwidth optimization. Keep input traces short, balance their geometry, and isolate the analog path from clocks, relays, and high-current switching stages. Calibration should include offset and gain measurement across the intended temperature range.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho INA333SKGD1 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này |
|---|---|
| Package | Bare die with 9 terminals |
| Brand | Texas Instruments |
| Amplifier Type | Precision instrumentation amplifier |
| Minimum Supply Voltage | 1.8 V |
| Quiescent Current | 50 uA |
| Gain Range | 1 to 1000 |
| Offset Voltage | 25 uV at 25 degrees C, gain >= 100 |
| Offset Voltage Drift | 0.2 uV/degree C, gain >= 100 |
| Common-Mode Rejection | 100 dB at 25 degrees C, gain >= 10 |
| Slew Rate | 0.16 V/us |
| Output Type | Rail-to-rail output |
| Temperature Grade | Military |
Bảo phân biệt quan trọng
- Bare-die construction supports compact custom assemblies (vsINA333SJD)
- Very low quiescent current for portable sensing (vsINA317)
- Precision zero-drift offset performance (vsINA333SHKJ)
Ghi chú thiết kế
Route the two differential inputs as a closely matched pair and connect the gain-setting network directly to the corresponding INA333SKGD1 terminals. Sensitive die pads should have short copper paths to the source and ADC. Maintain symmetry between input and return routes, avoid vias where practical, and keep the assembly free of flux residue because contamination can create leakage paths across high-impedance instrumentation-amplifier inputs.
The 50 uA quiescent current is the amplifier’s supply demand, not the total system consumption. Include sensor excitation, ADC reference, gain-resistor current, leakage, and external load when calculating battery life. Bypass each supply connection locally with the capacitance recommended by the Texas Instruments INA333 datasheet and verify startup, shutdown, and supply sequencing across the complete operating range.
Choose RG according to G = 1 + (100 kOhm divided by RG), then include resistor tolerance and temperature coefficient in the gain-error budget. At high gain, follow the manufacturer guidance for the resistor and its associated capacitor to control gain-bandwidth behavior. Check input common-mode voltage, output swing, and slew-rate requirements under the intended load rather than relying on nominal supply limits alone.
Do not treat packaged INA333 order codes as mechanical substitutes for INA333SKGD1. The target is a nine-terminal bare die, and changing to a VSSOP, WSON, or other package requires a different footprint, pin assignment, and assembly process. For any proposed substitute, obtain the manufacturer die drawing and verify pad numbering, die orientation, exposed connections, thermal limits, and ordering status before releasing fabrication files.
Thông tin tuân thủ
The INA333SKGD1 is identified as a military-grade bare-die ordering option. Military temperature grade does not establish AEC-Q100 automotive qualification. Exact RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from Texas Instruments for this ordering option.