ISL8487IPZ - 250kbps RS-485/422 Transceiver | Renesas
MPN: ISL8487IPZ ✓ Hoạt độngISL8487IPZ Tóm tắt
An RS-485/RS-422 transceiver is an interface IC that converts logic-level signals into differential bus signals and receives differential bus signals back into CMOS-compatible logic. The ISL8487IPZ belongs to the transceiver hierarchy of RS-422/RS-485 interface ICs, supporting robust point-to-point or multipoint communication over cables and printed-circuit-board interconnects. Its differential signaling improves common-mode noise rejection compared with single-ended digital interfaces.
Key features include support for both RS-485 and RS-422 protocols, 4.5 V to 5.5 V supply operation, 70 mV receiver hysteresis, and a 1/8 unit-load receiver input. The 1/8 unit-load rating allows more receivers to share a bus than a conventional quarter-unit-load receiver. ESD protection of ±15 kV improves interface resilience in industrial environments where cables can be exposed to electrostatic discharge.
The BiCMOS implementation combines bipolar interface characteristics with CMOS-compatible logic operation. A half-duplex architecture allows the driver and receiver to share a differential pair, reducing wiring in two-wire networks. The 250 kbps signaling rate supports moderate-speed industrial control, automation, instrumentation, and embedded data links while retaining compatibility with established RS-485 and RS-422 equipment.
Typical uses include factory automation controllers, process-monitoring equipment, sensor networks, industrial data acquisition, building controls, and embedded systems communicating with remote peripherals. The device is particularly useful where low power, a fractional unit load, ESD protection, and a through-hole 8-pin PDIP package are important design priorities.
PCB design should preserve the recommended differential trace geometry and provide a low-impedance return path. Bus termination, biasing, protection, and grounding should be selected for the cable length, topology, and environmental conditions. The ISL8487IPZ is a general-purpose interface device rather than a power component, so thermal analysis centers on surrounding circuitry and bus fault energy rather than the transceiver junction alone.
This product page combines package information, interface characteristics, drop-in replacement guidance, application-oriented circuit guidance, and a parameter comparison to help engineers evaluate transceiver selection and board-level implementation.
Bộ thay thế dễ dàng lắp đặt cho ISL8487IPZ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ISL8487IPZ (cùng hình factor và footprint) — khác nhau ở Duplex Mode, Package.
ISL8487EIPZ
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
MAX487CPA+
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
ISL8487IPZ Thông số kỹ thuật
| Product Type | RS-485/RS-422 half-duplex transceiver |
| Technology | BiCMOS |
| Điện áp cung cấp | 5 V |
| Operating Supply Voltage Range | 4.5 V to 5.5 V |
| Number of Drivers | 1 driver |
| Number of Receivers | 1 receiver |
| Supported Protocols | RS-422 and RS-485 |
| Duplex Mode | Half duplex |
| Maximum Data Rate | 250 kbps |
| Receiver Unit Load | 1/8 unit load |
| Receiver Hysteresis | 70 mV |
| ESD Protection | ±15 kV |
| Khoảng nhiệt độ hoạt động | -40°C to +85°C |
| Hộp | 8-pin PDIP, MS-001BA |
| Package Pitch | 7.62 mm |
| Kiểu lắp đặt | Through hole |
| Standard Packaging | Tube |
Hướng dẫn cấu hình chân ISL8487IPZ 7.62 mm
Cấu hình chân cho ISL8487IPZ (7.62 mm gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho ISL8487IPZ.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
ISL8487IPZ phù hợp cho 6 Áp dụngs: Factory Automation Controller Networks, Industrial Sensor Data Acquisition, Process Monitoring Equipment, Building and HVAC Control Links, Instrumentation and Test Equipment, Embedded RS-485 Communication Ports.
Factory Automation Controller Networks
The ISL8487IPZ fits factory automation links that distribute commands and sensor readings over balanced cable pairs at data rates up to 250 kbps. Its 1/8 unit-load receiver allows more monitoring nodes to share a bus than a quarter-unit-load receiver, while 70 mV hysteresis helps reject noise from nearby motor drives and switching equipment. Place the transceiver at a cable entry point, follow the datasheet bias and termination recommendations, and provide a low-impedance ground reference. The 250 kbps limit should be checked against total cable length and the number of nodes.
Được đề xuất
Industrial Sensor Data Acquisition
The ISL8487IPZ is suitable for sensor networks where a central controller reads distributed measurements over an RS-485 bus. Differential signaling reduces susceptibility to common-mode voltage, and the 1/8 unit load reduces bus loading so more remote sensing nodes can operate without exceeding the driver budget. Its ±15 kV ESD protection is valuable where field cables may be touched during installation or maintenance. Designers should still assess whether longer cables require additional surge protection and verify that the complete system remains within the 250 kbps signaling limit.
Được đề xuất
Process Monitoring Equipment
The ISL8487IPZ supports process-monitoring equipment that exchanges pressure, temperature, and valve-status information between a control panel and remote instrumentation. The 5 V operating range fits conventional embedded logic supplies, while the single-driver, single-receiver arrangement simplifies a two-wire half-duplex implementation. Its fractional unit load permits denser instrument networks than a 1/4 unit-load transceiver. Use differential routing with consistent impedance, provide fail-safe biasing at one designated location, and confirm that grounding arrangements avoid injecting noise into the reference plane.
Được đề xuất
Building and HVAC Control Links
The ISL8487IPZ can connect HVAC controllers, room modules, dampers, and environmental sensors through an RS-485 network. Building-control cables often pass near relays, lighting electronics, and variable-frequency equipment, making the receiver's 70 mV hysteresis and ±15 kV ESD protection useful. The 1/8 unit-load receiver allows multiple room controllers to share a bus, provided the calculated load remains below the allowed total. Use the device as a bus transceiver rather than an isolated interface when ground-offset limits would be exceeded.
Được đề xuất
Instrumentation and Test Equipment
The ISL8487IPZ is appropriate for bench and field instrumentation that needs a reliable differential link to external fixtures or remote measurement equipment. A 250 kbps data rate is sufficient for many command and status protocols, while the 1/8 unit load permits several low-power receiving sections to monitor the same bus. The PDIP package is straightforward to prototype, repair, and socket where appropriate. For laboratory systems with long unshielded leads, add suitable surge protection and verify connector shields and ground references before energizing the interface.
Được đề xuất
Embedded RS-485 Communication Ports
The ISL8487IPZ adds a standard industrial communication port to an embedded controller or data logger. One driver and one receiver are sufficient for a two-wire half-duplex bus, while the fractional receiver load supports multi-drop field networks. The 5 V supply operation and 8-pin PDIP format simplify integration with through-hole controller boards and legacy equipment. Firmware must manage bus direction, prevent simultaneous transmission, and include timeout handling so a disabled driver cannot hold the line in an active state.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ISL8487IPZ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | ISL8487EIPZ | MAX487CPA+ |
|---|---|---|---|
| Manufacturer | Renesas Electronics | Renesas Electronics | Maxim Integrated |
| Package | 8-PDIP | 8-PDIP - same | 8-PDIP - same |
| Transceiver Configuration | 1 driver / 1 receiver | 1 driver / 1 receiver | 1 driver / 1 receiver |
| Supported Protocols | RS-422 and RS-485 | RS-422 and RS-485 | RS-422 and RS-485 |
| Duplex Mode | Half duplex | Half duplex | Half duplex |
| Nominal Supply Voltage | 5 V | 5 V | 5 V |
| Maximum Data Rate | 250 kbps | 250 kbps class | 250 kbps class |
Bảo phân biệt quan trọng
- Lower bus loading supports denser networks (vsMAX487CPA+)
- Defined industrial ESD protection (vsMAX487CPA+)
- Through-hole package continuity within the Renesas family (vsISL8487EIPZ)
Ghi chú thiết kế
Route the differential pair as a controlled-impedance pair and keep the driver, receiver, protection devices, and optional termination close together. Avoid stubs and sharply divergent traces because reflected signals can distort the receiver threshold at 250 kbps. Provide a continuous ground reference beneath the interface and separate the transceiver ground connection from noisy power-return paths where the layout permits.
Do not assume every 8-PDIP RS-485 transceiver has the same receiver loading. The ISL8487IPZ presents a 1/8 unit load, while the MAX487CPA+ presents a 1/4 unit load, reducing the conventional maximum receiver count by 50%. Recalculate the total bus load and verify enable polarity, driver-disable behavior, and fail-safe biasing before using either part as a production replacement.
Install termination only where it belongs in the network topology, and apply fail-safe bias at one carefully selected location rather than at every node. For exposed field cables, add appropriately rated surge and ESD protection with a short return path to ground. Keep protection switching transients away from the receiver inputs and verify that added protection capacitance does not degrade the intended 250 kbps signal rate.
Use the manufacturer pin-description table to assign the 8-pin PDIP connections and preserve the documented receiver-enable and driver-control functions. A through-hole package does not remove the need for controlled bus geometry: keep outgoing cable stubs short, maintain clearance from switching nodes, and verify the ground reference at both ends of the cable. The device is not an isolated interface, so system ground offsets must remain within the intended operating range.
Thông tin tuân thủ
The manufacturer documentation excerpt identifies BiCMOS technology and ±15 kV ESD protection but does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status.