MAX132CNG - ±18-Bit Serial ADC with Multi-Slope Integration | Maxim Integrated
MPN: MAX132CNG ✓ Hoạt độngMAX132CNG Tóm tắt
An integrating ADC (also called a dual-slope or multi-slope converter) is a type of data converter which performs analog-to-digital conversion by integrating the input signal over a fixed time window, then de-integrating against a reference voltage. ADCs sit in the broader data converter family inside the data acquisition (DAQ) signal chain: sensor -> signal conditioning -> ADC -> digital processing, where they convert real-world analog signals into digital codes for microcontrollers or processors.
Key features include ±0.006% full-scale-range (FSR) accuracy at 16 conversions per second, 15 µVRMS low-noise performance, and ±2 pA input current over the ±512 mV full-scale input range (2 µV/LSB). The MAX132 draws only 60 µA in normal operation and drops to 1 µA in sleep mode, making it attractive for low-duty-cycle battery-powered measurement systems. The 4-wire serial interface connects easily to microcontrollers, and the chip includes a programmed output port for an external multiplexer and programmable-gain amplifier (PGA).
The internal architecture combines an integrator, integrator-comparator logic, and a serial output shift register with on-chip oscillator and reference buffer. Multi-slope integration reduces conversion time versus classic dual-slope designs while still providing excellent 50 Hz/60 Hz normal-mode rejection, which is critical for industrial weighing and panel-meter applications where mains-frequency noise dominates.
Typical applications include precision weigh scales, panel meters, data-acquisition systems, portable battery-powered instrumentation, temperature measurement with cold-junction compensation, and digital multimeter (DMM) front ends. The wide 0C to +70C commercial operating range and sleep-mode current also suit remote telemetry and data-logger designs.
When designing with this device, ensure the input common-mode voltage stays within the supply rails and place a 10 uF bypass capacitor close to the supply leads. Because the MAX132 has no on-chip digital calibration, system-level zero and full-scale trim with the on-chip OFFSET and REFERENCE trim pins is recommended for best accuracy.
This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone.
Bộ thay thế dễ dàng lắp đặt cho MAX132CNG — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với MAX132CNG (cùng hình factor và footprint) — khác nhau ở Resolution, Package, Input Type, Configuration, Number of Inputs.
MAX132CNG+
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
MAX132ENG
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
MAX132CWG+
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →MAX132C/D
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
MAX132CNG Tỷ lệ tối đa & tính chất điện
| Không có thông số kỹ thuật sẵn có |
Cấu hình chân MAX132CNG
| Chân 1 | V+ |
| Chân 2 | REF+ |
| Chân 3 | REF- |
| Chân 4 | AIN+ |
| Chân 5 | AIN- |
| Chân 6 | AGND |
| Chân 7 | INT |
| Chân 8 | BUF |
| Chân 9 | OSC1 |
| Chân 10 | OSC2 |
| Chân 11 | V- |
| Chân 12 | NC |
| Chân 13 | DGND |
| Chân 14 | CS |
| Chân 15 | SCLK |
| Chân 16 | DOUT |
| Chân 17 | SLEEP |
| Chân 18 | EXTCLK |
| Chân 19 | MUX/PGA OUT0 |
| Chân 20 | MUX/PGA OUT1 |
| Chân 21 | MUX/PGA OUT2 |
| Chân 22 | MUX/PGA OUT3 |
| Chân 23 | OFFSET TRIM |
| Chân 24 | REFERENCE TRIM |
Ứng dụng tiêu biểu
MAX132CNG phù hợp cho 6 Áp dụngs: Precision Weigh Scales, Panel Meters and Digital Multimeters, Battery-Powered Data Loggers, Industrial Data Acquisition Systems, Temperature Measurement with Cold-Junction Compensation, Remote Telemetry and Sensor Nodes.
Precision Weigh Scales
Được đề xuất
Panel Meters and Digital Multimeters
Được đề xuất
Battery-Powered Data Loggers
Được đề xuất
Industrial Data Acquisition Systems
Được đề xuất
Temperature Measurement with Cold-Junction Compensation
Được đề xuất
Remote Telemetry and Sensor Nodes
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho MAX132CNG — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | MAX132CNG+ | MAX132ENG | MAX132CWG+ | MAX132C/D |
|---|---|---|---|---|---|
| Package | PDIP-24 (narrow, 300-mil) | PDIP-24 (narrow, 300-mil) - same | PDIP-24 (narrow, 300-mil) - same | SOIC-24 (wide, 300-mil) - same 300-mil body | PDIP-24 (narrow, 300-mil) - same |
| Brand | Analog Devices / Maxim Integrated | Analog Devices / Maxim Integrated - same | Analog Devices / Maxim Integrated - same | Analog Devices / Maxim Integrated - same | Analog Devices / Maxim Integrated - same |
| Resolution | ±18-bit | ±18-bit | ±18-bit | ±18-bit | ±18-bit (untrimmed die sale) |
| Conversion Rate | 100 conv/sec max | 100 conv/sec max | 100 conv/sec max | 100 conv/sec max | 100 conv/sec max |
| Operating Temperature | 0C to +70C (commercial) | 0C to +70C | -40C to +85C (extended) | 0C to +70C | 0C to +70C |
| Supply Current (Normal) | 60 µA | 60 µA | 60 µA | 60 µA | 60 µA |
| Supply Current (Sleep) | 1 µA | 1 µA | 1 µA | 1 µA | 1 µA |
| RoHS / Lead-Free | Compliant (lead-free + suffix variant) | Compliant | Compliant | Compliant | Non-compliant (die sale) |
Bảo phân biệt quan trọng
- Multi-slope integrating topology provides inherent 50 Hz/60 Hz mains-noise rejection (vsMAX1270BENG (sigma-delta 12-bit))
- Ultra-low sleep-mode current enables multi-year battery operation (vsMAX1309ECM/V+ (12-bit multi-channel SAR))
- Programmed serial output controls external MUX and PGA without extra GPIO (vsDiscrete MUX/PGA designs)
Ghi chú thiết kế
The MAX132CNG operates from dual ±5V supplies; for single-rail systems, generate the negative rail with an ICL7660 or equivalent charge pump. Place 10 µF bypass capacitors close to V+ and V- pins and a 0.1 µF ceramic in parallel for high-frequency decoupling. Tie AGDG and DSND at a single star point near the IC to avoid ground-loop noise that could degrade the 15 µVRMS noise floor.
Keep the analog input traces (AIN+, AIN-) short and guarded by analog ground to minimize leakage and pickup. Route digital signals (CS, SCLK, DOUT) away from the integrator and buffer amplifier outputs (INT, BUF) because the integrator capacitor node is high-impedance. Place the external integrator and buffer capacitors on the same side of the board as the IC, with short traces to minimize stray pickup.
Do not exceed the ±512 mV differential input range or the input ESD protection diodes will forward-bias and inject error. Use the OFFSET TRIM (pin 23) and REFERENCE TRIM (pin 24) potentiometers to calibrate system zero and full-scale at production; the multi-slope integration is sensitive to reference drift, so use a low-drift external reference. Avoid running the device above 16 conv/sec if you need the ±0.006% FSR accuracy.
The MAX132CNG's 4-wire serial interface shares its output with programmed MUX/PGA control bits. When reading conversion results, capture all bits in the correct order; do not clock additional cycles inadvertently because the MUX/PGA output bits are interleaved. Use the CS pin to frame each conversion read cleanly and avoid bus contention if multiple SPI devices share the bus.
Thông tin tuân thủ
RoHS compliant per distributor listings. AEC-Q100 not applicable - commercial/extended grade only. Lead-free MAX132CNG+ variant available. For halogen-free status refer to the manufacturer datasheet (DPHA data not found in Verified Web Data).