AD629BN - ±270V High Common-Mode Difference Amplifier | Analog Devices
MPN: AD629BN ✓ 啟用中AD629BN 概覽
A difference amplifier is a specialized amplifier IC that amplifies the voltage difference between two inputs while rejecting a voltage common to both inputs. This category sits within amplifier ICs and instrumentation signal-chain devices. It is particularly useful when a sensor, shunt, transducer, or measurement node operates at a high DC voltage but the useful information is represented by a comparatively small differential signal.
The AD629BN provides a differential gain of unity. To achieve its high common-mode range, an internal resistor divider attenuates the noninverting input by a factor of 20. Other internal resistors, including the feedback network, restore the overall differential gain to unity. This architecture allows accurate differential measurement without changing the nominal system gain.
The manufacturer identifies the AD629 as a production device and describes it as a precision device for measuring differential signals in the presence of common-mode voltages up to ±270 V. Its integrated resistor network simplifies the external circuit compared with a discrete difference-amplifier implementation. The eight-pin PDIP package also supports conventional through-hole assembly and prototype rework.
Typical uses include power-converter feedback monitoring, motor-drive bus measurement, industrial control sensing, battery-system instrumentation, and high-voltage test equipment. In these applications, the AD629BN can reject the large common-mode voltage while preserving a differential voltage measurement suitable for an ADC, comparator, control loop, or diagnostic circuit.
A key design consideration is that the input common-mode voltage must remain within the device's specified operating range under all transient and fault conditions. Designers should also verify the allowed differential input range, supply requirements, output swing, bandwidth, and gain error against their exact operating conditions using the manufacturer datasheet before finalizing the circuit.
This product page combines the AD629 architecture, operating-range details, package information, replacement guidance, and application-focused design notes to support faster component selection, PCB planning, and precision signal-chain design.
直接替換替代品,適用於 AD629BN — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD629BN (相同外形與佔位) — 差異在於 Common-Mode Input Voltage Range, Mounting Type, Package.
AD629BNZ
✅ 直接替換📋 參考替代品(不在目錄中)
AD629ANZ
✅ 直接替換📋 參考替代品(不在目錄中)
AD629BN 最大額定值與電氣特性
| Product Type | Precision difference amplifier |
| Common-Mode Input Voltage Range | ±270 V |
| Differential Gain | 1 V/V (unity gain) |
| Internal Noninverting Attenuation Ratio | 20:1 |
| 腳位數 | 8 pins |
| 封裝 | PDIP-8 |
| 安裝類型 | Through-hole |
| Device Type | Single amplifier |
AD629BN pdip-8 腳位配置指南
AD629BN(pdip-8 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD629BN.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD629BN 適用於 6 應用s: High-Voltage Industrial Sensor Interface, Power-Converter Feedback Monitoring, Motor-Drive DC-Bus Measurement, Battery-Pack Balance Monitoring, High-Voltage Test and Measurement, Precision Bridge and Shunt Readout.
High-Voltage Industrial Sensor Interface
The AD629BN fits measurement nodes where two sensing wires can sit at a common-mode potential as high as ±270 V while carrying a small differential signal. Its unity-gain difference-amplifier architecture rejects the shared voltage and presents the differential component to a controller or ADC. The integrated 20:1 noninverting attenuation and feedback network simplify the front end. Designers should verify transient limits, input protection, bandwidth, and downstream signal range at the highest expected bus voltage.
推薦
Power-Converter Feedback Monitoring
The AD629BN can monitor a small voltage difference across a converter shunt or sensing network even when the power stage operates at a high DC bus voltage. Its ±270 V common-mode range is useful for isolating the useful differential feedback signal from the switching-node potential, while unity gain keeps the nominal transfer straightforward. Validate converter transients, bandwidth requirements, output settling, and common-mode excursions before using the amplifier directly at the switching node.
推薦
Motor-Drive DC-Bus Measurement
The AD629BN is suitable for sensing a low-level differential signal in a motor-drive system where the high-voltage bus is common to multiple input nodes. The ±270 V common-mode capability allows the device to operate without external high-voltage attenuation when the measured node remains within its absolute limits. Use appropriate surge and transient protection, maintain signal ground integrity, and confirm that the amplifier's response bandwidth covers the required diagnostics and control-loop bandwidth.
推薦
Battery-Pack Balance Monitoring
The AD629BN can support differential monitoring of battery cells or packs when the cell stack imposes a high common-mode voltage on the measurement input. Its unity-gain behavior is useful when the system must preserve a small voltage difference for an ADC, comparator, or balancing controller. Check the exact differential input limit, supply arrangement, error over temperature, and protection strategy for series-cell systems rather than assuming the common-mode rating covers every transient condition.
推薦
High-Voltage Test and Measurement
The AD629BN provides a compact way to observe small differential signals in high-voltage test fixtures where both input nodes can share a large voltage relative to the measurement system. The unity-gain architecture and integrated resistor network can simplify instrumentation around shunt elements and sensor bridges. Confirm input protection, isolation requirements, common-mode accuracy, bandwidth, and output headroom in the complete fixture to avoid overloading the amplifier during switching or fault tests.
推薦
Precision Bridge and Shunt Readout
The AD629BN can read a bridge or shunt whose differential output is small but whose common-mode voltage is high. Unity gain preserves the scale of the differential measurement, while the internal resistor network provides a defined difference-amplifier function. For instrumentation-grade accuracy, verify the applicable grade, gain error, offset, input bias current, output swing, and temperature coefficient. Input filtering and protection should be designed to preserve accuracy without adding excessive loading or leakage.
推薦
推薦產品摘要
工程參考資料,適用於 AD629BN — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD629BNZ | AD629ANZ | INA117P |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | PDIP-8 | PDIP-8 | PDIP-8 | PDIP-8 |
| Function | Precision difference amplifier | Precision difference amplifier | Precision difference amplifier | Precision unity-gain difference amplifier |
| Differential Gain | 1 V/V (unity gain) | 1 V/V (unity gain) | 1 V/V (unity gain) | 1 V/V (unity gain) |
| Number of Pins | 8 pins | 8 pins | 8 pins | 8 pins |
| Mounting Style | Through-hole | Through-hole | Through-hole | Through-hole |
主要差異化特點
- Very high common-mode measurement range (對比INA117P)
- Integrated difference-amplifier resistor network (對比INA117P)
- Closest same-family ordering option (對比AD629ANZ)
設計說明
Do not treat the ±270 V common-mode rating as permission to exceed the separate differential input, absolute maximum, or supply-voltage limits. Review the AD629 manufacturer data sheet for every input and output constraint, then calculate worst-case conditions including startup, load dump, switching spikes, and fault states. Add input protection where the external system can exceed those limits, and ensure protection leakage does not degrade the intended measurement accuracy.
Keep the input, output, supply, and reference routing compact to minimize susceptibility to coupled noise in a high-voltage environment. Place input filtering and protection close to the amplifier pins, maintain a continuous return path, and avoid long parallel traces that can capacitively pick up switching-node energy. Confirm the pin functions in the manufacturer package drawing before assigning PCB nets, since the integrated resistor topology depends on exact pin connections.
Validate the complete signal path at the operating common-mode voltage and required measurement bandwidth. The internal divider attenuates the noninverting input by a factor of 20, while the feedback network restores unity differential gain, so parasitic capacitance, leakage, and ground movement can influence practical accuracy. Use short input routes, appropriate bypass capacitors, and an output path that keeps the amplifier within its specified operating region under startup and overload conditions.
合規資訊
The Analog Devices product page identifies AD629 as a production device but does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for AD629BN.