AD642KH - Dual 1 MHz BiFET Op Amp | Analog Devices
MPN: AD642KH ✓ 啟用中AD642KH 概覽
A BiFET operational amplifier is an operational amplifier whose input stage uses junction field-effect transistors. This amplifier category belongs to the hierarchy of operational amplifier, analog amplifier, analog signal-conditioning IC, and power-management-independent semiconductor. JFET inputs provide very low input bias current, while the bipolar fabrication and laser trimming described by Analog Devices support controlled offset voltage and close matching between the two amplifiers.
The AD642 family emphasizes precision and channel matching. Its ion-implanted JFET inputs are paired with monolithic bipolar circuitry and laser-wafer trimming. Important features include a maximum low offset voltage of 500 uV, a maximum warmed input bias current of 35 pA, low input-voltage noise, high open-loop gain, low quiescent current, and specified crosstalk at 1 kHz. These characteristics make each channel suitable for guarding, instrumentation, photodiode interfaces, and high-impedance buffer applications.
The device operates from dual supplies up to ±18 V as identified for the AD642KH. The exact common-mode input range, output swing, supply-current limits, and full operating-temperature limits must be taken from the pin and electrical tables in the manufacturer datasheet. Because the device uses a hermetically sealed metal-can package, mechanical clearance and lead-bend requirements deserve attention during PCB assembly and thermal design.
Typical uses include two-channel precision buffers, low-current transducers, dielectric and capacitance measurement front ends, photodiode amplification, and industrial instrumentation. In a transimpedance configuration, the AD642KH converts weak sensor currents into voltages while its JFET inputs limit the current drawn from the sensor. Its dual matched channels can also be used for differential monitoring where channel-to-channel tracking is important.
When laying out the circuit, keep input leads short and isolate sensitive input nodes from switching nodes and high-current return paths. Use the manufacturer pin-description table when assigning the eight leads, and check the package drawings for orientation and lead spacing before assembly. Decoupling capacitors should be placed close to the supply pins, while the input network should avoid leakage paths that could undermine the low 35 pA bias-current capability.
This product page combines the AD642KH electrical characteristics, matched-channel benefits, packaging guidance, verified drop-in alternatives, application patterns, and selection trade-offs. It is intended to help engineers determine whether the hermetically sealed 8-pin TO-99 AD642KH is suitable for a precision, high-impedance circuit before beginning layout.
直接替換替代品,適用於 AD642KH — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD642KH (相同外形與佔位) — 差異在於 Amplifier Type, Input Voltage Noise, Maximum Offset Voltage, Number of Channels.
AD642JH
✅ 直接替換📋 參考替代品(不在目錄中)
AD642KH 最大額定值與電氣特性
| Amplifier Type | Dual precision operational amplifier |
| Number of Channels | 2 channels |
| Input Transistor Type | Ion-implanted JFET input |
| Internal Process | Monolithic bipolar with laser-wafer trimming |
| Gain-Bandwidth Product | 1 MHz |
| Maximum Offset Voltage | 500 uV |
| Maximum Offset Voltage, Listing Classification | 2,000 uV |
| Maximum Input Bias Current | 35 pA when warmed up |
| Input Voltage Noise | 2 V p-p |
| Crosstalk Measurement Frequency | 1 kHz |
| 供應電壓 | ±18 V |
| Open-Loop Gain | High |
| 靜態電流 | Low |
| Matching Characteristics | Matched offset voltage, offset voltage over temperature, and bias current |
| Package Type | 8-pin hermetically sealed TO-99 metal can |
| 安裝類型 | Through-hole |
| RoHS 狀態 | unknown |
| REACH Status | unknown |
AD642KH 8-pin hermetically sealed to-99 metal can 腳位配置指南
AD642KH(8-pin hermetically sealed to-99 metal can 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD642KH.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD642KH 適用於 6 應用s: Photodiode Signal Conditioning, Precision Instrumentation Amplification, High-Impedance Sensor Buffering, Capacitance Measurement Front End, Differential Sensor Monitoring, Low-Level Analog Signal Conditioning.
Photodiode Signal Conditioning
The AD642KH fits low-current photodiode front ends because its JFET input stage limits warmed input bias current to 35 pA while providing a 1 MHz gain-bandwidth product. Place the photodiode at the noninverting input and establish the transimpedance relationship with a feedback resistor and compensation capacitor selected from the manufacturer application guidance. The low 35 pA bias current reduces error in weak-current measurements, although input guarding, clean board materials, and leakage control remain essential. The dual matched channels can support a second signal for monitoring or differential correction when channel-to-channel tracking is valuable.
推薦
Precision Instrumentation Amplification
The AD642KH is appropriate for precision instrumentation front ends that require two closely related low-bias-current channels. Its matched offset voltage and matched bias-current characteristics help preserve signal relationships between measurement channels, while the 500 uV maximum low offset specification supports high-accuracy amplification. Each amplifier can be used as a low-level voltage buffer or as part of a difference amplifier. The practical benefit is reduced error from input bias current, although the overall accuracy still depends on resistor matching, reference quality, clean layout, and compliance with the datasheet common-mode and output-swing limits.
推薦
High-Impedance Sensor Buffering
The AD642KH can buffer sensors whose output impedance is high enough that amplifier input current would disturb the source. With a maximum warmed input bias current of 35 pA and low input-voltage noise, the device limits loading compared with higher-bias bipolar input stages. Use the amplifier as a voltage follower when preserving the sensor voltage is more important than current drive, or add gain when signal amplitude requires it. Guard the input node, minimize exposed board area, and avoid contamination from flux residues and humidity. Verify the final bias current and leakage at the actual operating temperature rather than relying only on the room-temperature headline value.
推薦
Capacitance Measurement Front End
The AD642KH is suitable for capacitance and dielectric measurement circuits where the sensor may present a very small current or charge signal. Its 1 MHz gain-bandwidth product supports useful signal bandwidth, and the JFET input stage avoids loading the sensor with bias current as high as that of conventional bipolar inputs. The amplifier can drive a guarded sensor node through a feedback network while the second channel provides monitoring, excitation return, or a reference buffer. Component leakage, guard spacing, dielectric absorption, and parasitic capacitance can dominate the result, so use guarded PCB construction and evaluate the complete measurement system across temperature.
推薦
Differential Sensor Monitoring
The AD642KH is useful in differential monitoring because its two amplifiers are designed with closely matched offset voltage and bias-current behavior. Each channel can buffer one side of a differential sensor, after which a downstream differential stage performs subtraction and common-mode rejection. Matching within the amplifier reduces gain error that might otherwise arise between the two channels. The implementation still requires close attention to resistor-network ratio accuracy, input bias-current cancellation, and the analog common-mode range. Because both channels operate in one hermetically sealed metal can, thermal proximity can also support stable comparative measurements when the package is mounted away from major heat sources.
推薦
Low-Level Analog Signal Conditioning
The AD642KH can condition low-level analog signals where offset, bias current, and channel matching affect measurement integrity. The 500 uV maximum low offset specification and 35 pA maximum warmed bias current make it appropriate for buffer and gain stages preceding measurement or control circuitry. The 1 MHz gain-bandwidth product allows operation beyond static precision measurements, provided stability and compensation are evaluated for the actual feedback network. Keep input traces short, maintain symmetric routing between channels, and decouple supply pins close to the device. Also check output swing, load, and output-current conditions against the manufacturer electrical tables before finalizing the signal chain.
推薦
推薦產品摘要
工程參考資料,適用於 AD642KH — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD642JH | AD642SH |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 8-pin TO-99 hermetically sealed metal can | 8-pin TO-99, same package | 8-pin TO-99, same package |
| Amplifier Configuration | Dual operational amplifier | Dual operational amplifier | Dual operational amplifier |
| Input Stage | Matched ion-implanted JFET inputs | Matched JFET inputs | Matched JFET inputs |
| Gain-Bandwidth Product | 1 MHz | 1 MHz class | 1 MHz class |
| Maximum Input Bias Current | 35 pA when warmed up | 35 pA class | 35 pA class |
| Supply Voltage | ±18 V | ±18 V | ±18 V |
| Offset and Bias Matching | Matched offset voltage, temperature tracking, and bias current | Matched-channel family construction | Matched-channel family construction |
| Input Voltage Noise | 2 V p-p as listed | 2 V p-p class | 2 V p-p class |
主要差異化特點
- Tighter offset tolerance within the same matched dual JFET family (對比AD642JH)
- Matched dual-channel architecture for differential measurement (對比AD642SH)
- Low bias current for high-source-impedance measurement (對比AD642JH)
設計說明
Keep the AD642KH input nodes short and surrounded by a grounded guard where the circuit operates with picoampere-scale bias current. Avoid routing sensitive inputs beside supply traces, relay contacts, high-impedance nodes, or exposed assembly contamination. The 8-pin TO-99 package also requires mechanical clearance for the metal can and its leads; confirm the manufacturer's package drawing before placing adjacent components or defining the board edge.
Place input and output signal paths symmetrically when both matched channels participate in a differential measurement. Keep feedback components close to the relevant amplifier pins and minimize loop area around the input nodes. Use a ground reference that remains quiet under changing sensor currents, because common ground impedance can convert supply and load variations into apparent input error even when the amplifier itself has excellent matching.
Do not infer the complete pinout, operating-temperature range, common-mode range, or output swing from the device description alone. Assign the eight TO-99 leads using the Analog Devices pin-description table and verify each electrical limit before applying maximum supply voltage. Also avoid substituting solely by suffix: AD642JH and AD642SH share the package and family architecture, but their precision-grade limits must be compared with the AD642KH requirements.
Monitor power dissipation at the actual supply voltage, output voltage, and load current. The dual amplifier can consume additional quiescent current when both channels operate at appreciable output levels. Use the manufacturer thermal information for the hermetically sealed metal-can construction and avoid placing the package next to a major heat source. Estimated: dissipated power equals the sum of each channel's supply-to-output voltage drop multiplied by its output current plus the relevant internal dissipation.
合規資訊
No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration is identified for AD642KH. The hermetically sealed TO-99 package is a mechanical and environmental construction detail, not proof of any particular compliance status.