AD704JN - Quad Picoampere Input Op Amp | Analog Devices
MPN: AD704JN ✓ 啟用中AD704JN 概覽
An operational amplifier is a high-gain, feedback-controlled analog building block used to amplify, buffer, filter, sum, and compare differential signals. The AD704 belongs to the broader precision-amplifier category and uses Superbeta bipolar input transistors. These transistors provide picoampere input bias current levels similar to FET-input amplifiers at room temperature, while offering lower input-bias-current drift over temperature than conventional BiFET-input amplifiers.
The AD704's four-amplifier architecture is particularly useful in precision current-measurement front ends, low-level sensor interfaces, electrochemical measurement systems, photodiode signal chains, and laboratory instrumentation. Picoampere input bias current reduces the disturbance that an amplifier can impose on a high-impedance source, while bipolar input devices can provide useful low-noise behavior in carefully designed applications. The low-power operating characteristic also supports portable and multi-channel instruments where the aggregate supply demand of four amplifiers matters.
Unlike FET-input amplifiers, the Superbeta bipolar input stage is specifically intended to keep bias-current drift relatively low as temperature rises. According to the Analog Devices AD704 product page, the bias current typically increases only at elevated temperature, whereas a BiFET amplifier can experience substantially greater bias-current variation. This distinction matters when source impedance, measurement accuracy, calibration stability, and ambient-temperature variation are all important design constraints.
Typical circuit roles include transimpedance amplification, precision current sensing, buffer stages, low-level differential amplification, and offset correction. The amplifier is most useful where the source current must not be significantly disturbed and where leakage from conventional input structures could corrupt a small measurement. Designers should still account for board-level contamination, connector leakage, guarding, input protection, offset voltage, noise, and the finite input impedance of the complete measurement system.
The principal design consideration is that picoampere input bias current does not eliminate all error sources. Input bias current multiplied by source impedance creates a systematic offset, while offset voltage, input-referred noise, drift, common-mode range, output swing, and resistor tolerance can dominate the final accuracy. Stable layouts, clean guard rings, appropriate feedback resistors, and suitable reference components are therefore as important as the op-amp selection itself.
This product record combines the manufacturer's device description with package, pricing, and cross-reference information to support sourcing and engineering evaluation. It also distinguishes a true same-footprint replacement from unrelated amplifier packages, helping designers confirm pin compatibility, assess measurement requirements, and plan a controlled redesign before changing the AD704JN in an existing precision analog circuit.
直接替換替代品,適用於 AD704JN — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
AD704JNZ
✅ 直接替換📋 參考替代品(不在目錄中)
AD704JN 最大額定值與電氣特性
| Amplifier Type | Quad precision bipolar operational amplifier |
| Number of Channels | 4 channels |
| Input Transistor Technology | Superbeta bipolar input transistors |
| Input Bias Current Class | Picoampere class |
| Bias-Current Temperature Drift | Typically increases only at +125 °C |
| Power Class | Low-power bipolar operational amplifier |
| Package Type | 14-pin through-hole DIP |
| 腳位數 | 14 pins |
| 安裝類型 | Through-hole |
AD704JN 腳位配置
| 腳位 1 | OUT A — Amplifier A output |
| 腳位 2 | -IN A — Amplifier A inverting input |
| 腳位 3 | +IN A — Amplifier A noninverting input |
| 腳位 4 | V- — Negative supply voltage |
| 腳位 5 | +IN B — Amplifier B noninverting input |
| 腳位 6 | -IN B — Amplifier B inverting input |
| 腳位 7 | OUT B — Amplifier B output |
| 腳位 8 | OUT C — Amplifier C output |
| 腳位 9 | -IN C — Amplifier C inverting input |
| 腳位 10 | +IN C — Amplifier C noninverting input |
| 腳位 11 | V+ — Positive supply voltage |
| 腳位 12 | +IN D — Amplifier D noninverting input |
| 腳位 13 | -IN D — Amplifier D inverting input |
| 腳位 14 | OUT D — Amplifier D output |
典型應用
AD704JN 適用於 6 應用s: Precision Transimpedance Amplification, Low-Level Current Sensing, Electrochemical Sensor Measurement, High-Impedance Buffering, Laboratory Instrumentation, Precision Differential Signal Conditioning.
Precision Transimpedance Amplification
The AD704JN fits transimpedance front ends because its picoampere-class input bias current minimizes the current drawn from a photodiode, electrochemical sensor, or other high-impedance source. Place the amplifier in an inverting configuration and select the feedback resistor to establish the required conversion gain. The Superbeta bipolar input stage also helps limit temperature-related bias-current variation, although photodiode capacitance, resistor parasitics, board leakage, and achievable bandwidth must be considered when stabilizing the stage. Guarding and a leakage-clean assembly process remain important because external contamination can exceed the amplifier's own input current.
推薦
Low-Level Current Sensing
The AD704JN is suitable for measuring small currents through a high-value sense resistor or when sensing currents in high-impedance branches. Picoampere-class input bias current reduces the measurement disturbance introduced by the amplifier, while the low-power quad architecture allows four channels to share one package in instrumentation. The practical error budget must include amplifier offset voltage, offset drift, resistor tolerance and drift, source leakage, and the voltage developed across the sensing element. Differential arrangements can reduce sensitivity to common-mode voltage, subject to the device's specified input and output ranges.
推薦
Electrochemical Sensor Measurement
The AD704JN fits electrochemical and chemical sensors whose output currents can be extremely small. Its picoampere input bias current helps preserve the sensor signal, and the bipolar Superbeta input stage offers controlled bias-current behavior over temperature compared with conventional BiFET inputs. A typical implementation uses one amplifier as a transimpedance converter and additional channels for reference or buffer functions. Stable operation depends on guarding, low-leakage connectors, chemically compatible materials, and careful PCB cleaning because contamination and humidity can dominate the sensor interface error.
推薦
High-Impedance Buffering
The AD704JN can buffer a high-impedance source when its input current must remain small enough not to disturb the measured node. The four amplifiers permit multiple buffered outputs or gain stages in one package, reducing board area compared with four separate devices. A unity-gain buffer configuration simplifies routing, but stability, input capacitance, output loading, and frequency response must be checked. Use guarding around high-impedance inputs and ensure the source remains within the amplifier's specified common-mode range. The device is particularly appropriate where low temperature-related bias-current drift is more valuable than selecting a dedicated FET-input buffer solely for its room-temperature noise specification.
推薦
Laboratory Instrumentation
The AD704JN is well suited to laboratory measurement equipment in which source leakage, offset drift, and repeatable behavior are more important than minimum package cost. Four channels can support a precision input stage, buffer, gain stage, and output driver within one 14-pin DIP. Layout should separate sensitive inputs from switching and power nodes, provide guarding where needed, and use stable reference resistors with suitable noise and drift characteristics. Calibration can remove static offset, but temperature variation, noise, leakage, and component tolerances must remain inside the instrument's measurement uncertainty.
推薦
Precision Differential Signal Conditioning
The AD704JN can condition small differential signals where low input current and controlled bias-current drift help preserve source integrity. Differential amplifier configurations provide signal rejection when component matching and resistor ratios are controlled, while the quad package allows two differential channels or a combination of differential and reference channels. Offset voltage, common-mode error, resistor-ratio mismatch, noise, and output-drive limits must be evaluated together. The low-power architecture benefits multi-channel portable instruments, although four channels operating simultaneously can increase total supply demand and board heating compared with a single amplifier.
推薦
推薦產品摘要
工程參考資料,適用於 AD704JN — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD704JNZ |
|---|---|---|
| Package | 14-pin through-hole DIP | 14-pin through-hole DIP |
| Brand | Analog Devices | Analog Devices |
| Number of Amplifiers | 4 channels | 4 channels |
| Mounting Style | Through-hole | Through-hole |
| Exact MPN Suffix Attributes | AD704JN | AD704JNZ |
主要差異化特點
- Picoampere-class input bias current (對比AD704JNZ)
- Lower bias-current drift over temperature (對比AD704JNZ)
- Four precision channels in one package (對比AD704JNZ)
設計說明
Keep the AD704JN input and feedback traces away from switching nodes, power inductors, and high-current return paths. For picoampere-class measurements, use a guarded layout, clean the PCB after assembly, and prevent flux residue or moisture from bridging sensitive nodes. Input current is only one part of the error budget; contamination-related leakage can otherwise dominate the measurement. Confirm the manufacturer's recommended layout and pin assignments in the AD704 data sheet before finalizing the PCB.
Do not select an amplifier from input-bias-current specifications alone. Offset voltage, offset drift, input-referred noise, common-mode range, output swing, bandwidth, and resistor precision can set the measurement error. For a transimpedance stage, calculate the feedback resistance from the required sensitivity and include source capacitance, amplifier stability, and resistor parasitic capacitance. The AD704JN's low input current helps with high-impedance sources but does not remove these other error mechanisms.
Evaluate both the per-amplifier and total package supply current because all four channels can operate simultaneously. Bypass the supply pins with the capacitance recommended in the manufacturer data sheet, place each bypass component close to its supply connection, and provide an uncomplicated return path. When using ± supplies, verify that both rail magnitudes remain inside the device's specified operating limits and that the supply rails are sequenced according to the manufacturer's guidance.
合規資訊
Compliance attributes were not identified in the manufacturer page excerpts or distributor listings. Confirm the current material and environmental declarations for the exact ordering suffix with Analog Devices.