AD774BKN - 12-Bit 8us SAR ADC | Analog Devices | Industrial
MPN: AD774BKN ✓ 啟用中AD774BKN 概覽
An ADC is a data-conversion IC that transforms an analog voltage into a numeric code for processing, measurement or control. The AD774B belongs to the successive-approximation, or SAR, ADC family and sits within the broader hierarchy of data-conversion integrated circuits and analog semiconductors. SAR converters are widely used when a system needs moderate resolution, deterministic sampling behavior, low external component count and direct digital-bus integration without a high-speed parallel data pipeline.
The AD774B's primary features include 12-bit resolution, an 8 microsecond maximum conversion time, two analog input channels as identified for the AD774BKN, an integrated reference and clock, and three-state output buffers. Its parallel interface supports microprocessor systems using 8-bit or 16-bit data buses. The three-state outputs allow multiple devices to share bus access when inactive, while the integrated reference and clock reduce the number of external support components required for a basic measurement channel.
The AD774B and AD674B use an industry-standard pin arrangement compatible with the AD574A family. Compared with the original AD574A, Analog Devices identifies faster conversion performance, improved access speed and lower power consumption in the B-generation converters. The AD774B is the faster member of the AD674B/AD774B pair, converting in no more than 8 microseconds, while the AD674B has a 15 microsecond maximum conversion time.
Typical uses include industrial process measurement, instrumentation, laboratory data acquisition, embedded control and legacy microprocessor systems requiring a parallel ADC. The integrated reference and clock are useful where component count and predictable sampling are priorities, while the tri-state output buffer simplifies bus sharing among converters and other peripheral devices. For new designs, interface timing and system-level compatibility should be checked carefully against the intended bus architecture.
Design attention should focus on input range, reference accuracy, acquisition timing, grounding and digital-bus contention. The datasheet pin-description and timing diagrams should be used to assign control signals and data lines, and unused outputs should remain disconnected when the parallel interface is not used. The 28-pin PDIP format favors through-hole legacy and industrial boards rather than compact surface-mount assemblies.
This page consolidates the AD774BKN's core converter characteristics, compatible family options, interface considerations and selection guidance. It also distinguishes true same-footprint choices from functionally similar converters that require different packages or interfaces, helping engineers assess replacement risk before modifying a PCB.
直接替換替代品,適用於 AD774BKN — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD774BKN (相同外形與佔位) — 差異在於 Mounting Type, Package, Analog Input Channels, Conversion Architecture, Input Range.
AD674BKN
✅ 直接替換聯絡詢價
查看資料表 →AD574AKN
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AD574ALN
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →AD774BKN 最大額定值與電氣特性
| 解析度 | 12 bit |
| Conversion Architecture | Successive approximation (SAR) |
| Maximum Conversion Time | 8 us |
| Analog Input Count | 2 inputs |
| Internal Reference | Included |
| Internal Clock | Included |
| Output Buffer | Three-state |
| Processor Interface | 8-bit and 16-bit microprocessor bus |
| 封裝 | 28-pin PDIP |
| 安裝類型 | Through-hole |
AD774BKN 28-pin pdip 腳位配置指南
AD774BKN(28-pin pdip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD774BKN.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD774BKN 適用於 6 應用s: Industrial Process Measurement, Legacy Microprocessor Data Acquisition, Laboratory Instrumentation, Embedded Control Systems, Sensor Interface Modules, Automated Test Equipment.
Industrial Process Measurement
The AD774BKN fits industrial process-measurement channels that require a 12-bit result without a separate reference and clock. Its 8 microsecond maximum conversion time provides faster acquisition than the 15 microsecond AD674BKN, while the integrated reference and clock reduce external support circuitry. The converter is placed between a conditioned sensor signal and a microprocessor-controlled data-acquisition system, with the parallel outputs sampled during the interval defined by the manufacturer timing diagrams. Engineers should verify the input range, reference accuracy and acquisition period before assigning the converter to pressure, temperature or level channels.
推薦
Legacy Microprocessor Data Acquisition
The AD774BKN is suited to legacy 8-bit and 16-bit microprocessor systems that require a direct parallel ADC connection. Its three-state output buffers allow the digital data bus to be released when the converter is not selected, supporting shared-bus arrangements. The 8 microsecond maximum conversion time provides a deterministic acquisition interval for a control loop or measurement cycle. Because this is a 28-pin PDIP device, it also favors established through-hole industrial and instrumentation boards. Firmware must honor the read, write and bus-control timing shown in the AD674B_774B manufacturer datasheet.
推薦
Laboratory Instrumentation
The AD774BKN can serve as the ADC stage in laboratory instrumentation where a compact, complete converter is valuable. Its 12-bit resolution and 8 microsecond maximum conversion time support measurements that do not require a high-speed waveform recorder but benefit from rapid sequential readings. The internal reference and clock reduce the component count on an instrument motherboard, while the parallel interface connects directly to a processor bus. Layout should keep analog input routing away from digital outputs, establish a low-impedance return path and follow the datasheet's reference and bypass recommendations to preserve measurement repeatability.
推薦
Embedded Control Systems
The AD774BKN is appropriate for embedded closed-loop control when the controller requires a complete 12-bit SAR ADC and can accommodate a parallel interface. The 8 microsecond maximum conversion time allows the controller to sample a conditioned feedback signal within a deterministic control interval. A typical arrangement places the converter between a bridge, potentiometer or external sensor conditioner and an embedded processor, with the internal reference and clock reducing external support components. Firmware should initiate conversion, observe the status timing and read the tri-state data outputs without causing bus contention.
推薦
Sensor Interface Modules
The AD774BKN can form the conversion core of a sensor interface module that outputs 12-bit parallel data to a host processor. Its integrated reference and clock are useful in compact modules where external support components are undesirable, and its 8 microsecond maximum conversion time supports reasonably rapid sensor updates. The analog front end must still condition the sensor output into the converter's specified input range while offering adequate settling time. Place the converter near the sensor input, maintain a clean ground reference and avoid routing high-current digital return paths through the analog input area.
推薦
Automated Test Equipment
The AD774BKN is useful in automated test equipment that records slow or moderate-speed measurements through a parallel processor interface. The 12-bit resolution provides adequate measurement granularity for many production and acceptance tests, and the 8 microsecond maximum conversion time supports shorter test-cycle intervals. Its three-state outputs can share a processor bus when the test controller coordinates device selection and data acquisition. Fixture design should minimize connector-to-ADC trace length, protect inputs from transients and provide clean grounding, while the host software must follow the converter's stated control and data-access sequence.
推薦
推薦產品摘要
工程參考資料,適用於 AD774BKN — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD674BKN | AD574AKN | AD574ALN | AD574AKD | ADS774JU |
|---|---|---|---|---|---|---|
| Package | 28-pin PDIP | 28-pin PDIP | 28-pin PDIP | 28-pin PDIP | 28-pin PDIP | 28-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Resolution | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit |
| Conversion Architecture | SAR | SAR | SAR | SAR | SAR | SAR |
主要差異化特點
- Faster maximum conversion time within the same Analog Devices family (對比AD674BKN)
- Complete converter integration reduces external support components (對比AD574AKN)
- Direct support for 8-bit and 16-bit microprocessor buses (對比ADS774JU)
設計說明
Route the analog input directly to the converter and keep digital control and data traces away from the input and reference pins. Follow the grounding arrangement in the AD674B_774B manufacturer datasheet, because a shared high-current return between analog and digital sections can corrupt the 12-bit result. Place bypass capacitors at the device supply pins with short return paths, and avoid adding test pads or long stubs beside the sensitive input node.
Use the AD774BKN's three-state outputs only when the bus controller guarantees that no other peripheral drives the same data lines. Establish the correct acquisition, conversion-complete and output-enable sequence in firmware, and observe the timing margins shown in the manufacturer datasheet. A parallel bus edge rate can create ringing on a long PCB trace, so use series damping when the host processor, cable or backplane requires it.
Do not treat the AD674BKN or an AD574A-family device as a timing-identical replacement for the AD774BKN. The AD674BKN converts in up to 15 microseconds rather than 8 microseconds, while older AD574A devices have different acquisition and conversion characteristics. Verify supply levels, input range, reference behavior, bus-control polarity, temperature grade and package construction before releasing a substitution to production.
The internal reference and clock simplify the circuit, but they do not eliminate input conditioning requirements. Confirm that the analog signal remains within the converter's specified range during startup, overload and adjacent-channel switching. For multiplexed systems, allow the source and its resistance to settle before conversion and confirm that the selected channel architecture matches the intended input configuration.
合規資訊
No specific RoHS, REACH, lead-free or halogen-free declaration was identified for the AD774BKN ordering code.