Analog Devices

ADM3050EBRWZ - 5.7kV Isolated CAN-FD Transceiver | Analog Devices

MPN: ADM3050EBRWZ ✓ 啟用中
5.7 kV rms Vdss 16-SOIC (SOIC-16) Package
MOQ: 1 |

ADM3050EBRWZ 概覽

The ADM3050EBRWZ is a 5.7 kV rms isolated controller area network (CAN) physical layer transceiver from Analog Devices, designed for CAN and CAN FD applications. It integrates a 2-channel digital isolator and a CAN transceiver into a single 16-lead SOIC package using Analog Devices' iCoupler technology. The device fully meets the CAN flexible data rate (CAN FD) ISO 11898-2:2016 requirements and supports data rates up to 12 Mbps.

A CAN transceiver is a physical layer device that connects a CAN controller to the differential bus lines (CANH and CANL). It converts the controller's logic-level signals to differential signals for transmission and vice versa for reception. In the system hierarchy, the ADM3050E sits between the CAN controller (often integrated in a microcontroller) and the twisted-pair bus, providing galvanic isolation to protect the controller and other low-voltage circuitry from high-voltage transients and ground potential differences.

Key features include 5.7 kV rms isolation voltage, compliance with ISO 11898-2:2016, support for CAN FD data rates up to 12 Mbps, and a 5V supply voltage. The device is available in a 16-lead SOIC package (SOIC-16) and is RoHS compliant. It is designed for industrial automation, building control, and automotive applications where robust communication and isolation are critical.

Technically, the ADM3050E uses iCoupler technology to combine isolation and transceiver functions, eliminating the need for external optocouplers and separate isolated power supplies. The device provides a fully isolated solution, with isolation between the CAN controller and the physical layer bus. It features a basic feature set, focusing on essential CAN communication without additional complexity.

Typical applications include industrial fieldbus networks, motor control systems, HVAC control, and electric vehicle charging stations. The high isolation voltage and CAN FD support make it suitable for harsh environments where noise and ground loops are common.

When designing with the ADM3050E, ensure proper PCB layout with adequate creepage and clearance distances for the isolation barrier. The device requires a 5V supply on both the logic side and the bus side, and external termination resistors may be needed depending on the bus configuration.

直接替換替代品,適用於 ADM3050EBRWZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

此系列的變體

與下列產品可直接替換的同系列型號: ADM3050EBRWZ (相同外形與佔位) — 差異在於 Protocol, Supply Voltage.

Analog Devices
Protocol: CAN FD
Supply Voltage: 3.3 V or 5 V
比較對象 ADM3050EBRWZ →

ADM3050EBRWZ-RL

✅ 直接替換
📦 16-SOIC
Same device, tape-and-reel packaging

📋 參考替代品(不在目錄中)

ADM3050ETRWZ-EP-RL

✅ 直接替換
📦 16-SOIC
Enhanced product variant with extended temperature range

📋 參考替代品(不在目錄中)

ADM3053BRWZ

⚡ 相同封裝 ⚠️ 規格未經驗證
Analog Devices
📦 16-SOIC
Isolated CAN Transceiver · 1/1 · CANbus · 2.5 kVrms · 5 V · 5 V or 3.3 V · Up to 1 Mbps · 110 or more

聯絡詢價

查看資料表 →

ISO1042DW

✅ 直接替換 ⚠️ 規格未經驗證
Texas Instruments
📦 16-SOIC
Galvanically isolated CAN FD transceiver · 5 Mbps · 1 Mbps · ISO 11898-2:2016 · ±70 V DC · ±30 V · 152 ns · 1.8 V to 5.5 V

聯絡詢價

查看資料表 →

ISO1044DW

✅ 直接替換 ⚠️ 規格未經驗證
📦 16-SOIC
Cross-brand, 5.7kV isolation, CAN FD, pin-compatible

📋 參考替代品(不在目錄中)

CTM1051KAT

✅ 直接替換 ⚠️ 規格未經驗證
📦 16-SOIC
Cross-brand, isolated CAN transceiver, pin-compatible

📋 參考替代品(不在目錄中)

ADM3050EBRWZ 規格

Type Isolated CAN Transceiver
Number of Drivers/Receivers 1/1
Protocol CANbus
Isolation Voltage 5.7 kV rms
資料速率 12 Mbps (max)
供應電壓 5 V
封裝 16-SOIC (SOIC-16)
安裝類型 Surface Mount
RoHS 狀態 Compliant
ISO 11898-2:2016 Compliance Yes
iCoupler Technology Yes
Number of Channels 2 (isolator)

ADM3050EBRWZ 腳位配置

SOIC-16 Package Pinout Diagram SOIC-16 16-pin, 3.9x9.9mm, P1.27mm, JEDEC MS-012. 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 SOIC-16
腳位 1 TXD — Transmit data input
腳位 2 GND1 — Logic side ground
腳位 3 VCC1 — Logic side supply voltage
腳位 4 RXD — Receive data output
腳位 5 VREF — Reference voltage output
腳位 6 CANL — Low-level CAN bus line
腳位 7 CANH — High-level CAN bus line
腳位 8 GND2 — Bus side ground
腳位 9 VCC2 — Bus side supply voltage
腳位 10 GND2 — Bus side ground
腳位 11 GND2 — Bus side ground
腳位 12 GND2 — Bus side ground
腳位 13 GND2 — Bus side ground
腳位 14 GND2 — Bus side ground
腳位 15 GND2 — Bus side ground
腳位 16 GND2 — Bus side ground

典型應用

ADM3050EBRWZ 適用於 6 應用s: Industrial Fieldbus Networks, Motor Control Systems, Building Automation, Electric Vehicle Charging Stations, Medical Equipment, Renewable Energy Systems.

🏭

Industrial Fieldbus Networks

The ADM3050EBRWZ provides isolated CAN communication for industrial fieldbus networks, ensuring reliable data transfer in noisy environments. Its 5.7 kV rms isolation protects controllers from ground potential differences and electrical transients, while CAN FD support enables high-speed data rates up to 12 Mbps. The device is ideal for connecting PLCs, sensors, and actuators in factory automation systems, where robust communication is critical for process control and monitoring.

⚡

Motor Control Systems

In motor control applications, the ADM3050EBRWZ enables isolated CAN communication between the motor drive and the central controller. The high isolation voltage prevents high-voltage motor transients from damaging low-voltage control electronics. CAN FD support allows for fast transmission of real-time control data, improving system responsiveness. The device's robust design ensures reliable operation in harsh industrial environments with high electromagnetic interference.

🏢

Building Automation

The ADM3050EBRWZ is well-suited for building automation systems, such as HVAC control and lighting networks. Its 5.7 kV rms isolation ensures safe communication between different building zones, preventing ground loops and protecting equipment from surges. CAN FD support enables efficient data exchange for monitoring and control, while the compact SOIC-16 package allows for space-saving PCB designs. The device's compliance with ISO 11898-2:2016 ensures interoperability with standard CAN networks.

🚗

Electric Vehicle Charging Stations

The ADM3050EBRWZ is ideal for electric vehicle (EV) charging stations, where isolated CAN communication is required between the charging controller and the vehicle's battery management system. The 5.7 kV rms isolation provides safety against high-voltage transients, while CAN FD support enables high-speed data transfer for charging status and control. The device's robust design ensures reliable operation in outdoor environments with temperature variations and electrical noise.

💊

Medical Equipment

In medical equipment, the ADM3050EBRWZ provides isolated CAN communication for patient monitoring systems and diagnostic devices. The high isolation voltage ensures patient safety by preventing electrical leakage between the device and the patient. CAN FD support allows for high-speed data transmission of vital signs and diagnostic data. The device's small footprint and low power consumption make it suitable for portable and compact medical devices.

🔧

Renewable Energy Systems

The ADM3050EBRWZ is used in renewable energy systems, such as solar inverters and wind turbines, for isolated CAN communication between power conversion stages and the central monitoring system. The 5.7 kV rms isolation protects against high-voltage transients from the power stage, while CAN FD support enables efficient data exchange for performance monitoring and fault detection. The device's wide operating temperature range and robust design ensure reliable operation in outdoor environments.

What is the isolation voltage of ADM3050EBRWZ?
The ADM3050EBRWZ provides 5.7 kV rms isolation voltage. According to the ADM3050E datasheet, this isolation rating is suitable for industrial applications requiring robust galvanic isolation between the CAN controller and the bus.
Does ADM3050EBRWZ support CAN FD?
Yes, the ADM3050EBRWZ fully meets the CAN flexible data rate (CAN FD) ISO 11898-2:2016 requirements and supports data rates up to 12 Mbps. This makes it suitable for high-speed CAN FD networks.
What is the package type of ADM3050EBRWZ?
The ADM3050EBRWZ comes in a 16-lead SOIC (SOIC-16) package. This surface-mount package is widely used and supports automated assembly.
What is the supply voltage for ADM3050EBRWZ?
The ADM3050EBRWZ operates from a 5V supply. This is typical for CAN transceivers and simplifies power supply design in systems that already have a 5V rail.
Where can I buy ADM3050EBRWZ?
ADM3050EBRWZ is available from major distributors such as DigiKey and Mouser. As of 2026-08-23, DigiKey lists it as in stock with pricing starting at $5.42 for single units.
What is the price of ADM3050EBRWZ?
As of 2026-08-23, the price of ADM3050EBRWZ is approximately $5.42 for 1 unit, $4.88 for 10 units, and $3.28 for 1000 units, based on DigiKey pricing.
What is the lead time for ADM3050EBRWZ?
The lead time for ADM3050EBRWZ is typically 1-2 weeks from major distributors like DigiKey and Mouser, depending on stock levels. Check distributor websites for current availability.
Is ADM3050EBRWZ in stock?
As of 2026-08-23, ADM3050EBRWZ is in stock at DigiKey and Mouser. Availability can change, so check the distributor websites for real-time inventory.
ADM3050EBRWZ vs ADM3050ETRWZ-EP-RL - which is better?
The ADM3050EBRWZ is the standard version, while the ADM3050ETRWZ-EP-RL is an enhanced product (EP) variant with extended temperature range and possibly different packaging. For most industrial applications, the standard ADM3050EBRWZ is sufficient; choose the EP version for extreme temperature environments.
What is the difference between ADM3050EBRWZ and ADM3050ETRWZ-EP-RL?
The main difference is that the ADM3050ETRWZ-EP-RL is an enhanced product variant with a wider operating temperature range and potentially different reliability qualifications. Both share the same core isolation and CAN FD functionality.
When should I choose ADM3050EBRWZ over a non-isolated CAN transceiver?
Choose ADM3050EBRWZ when you need galvanic isolation between the CAN controller and the bus to protect against ground loops, voltage transients, and noise. Non-isolated transceivers are cheaper but do not provide this protection.
Is ADM3050EBRWZ suitable for industrial automation?
Yes, the ADM3050EBRWZ is ideal for industrial automation due to its 5.7 kV rms isolation, CAN FD support, and robust design. It is commonly used in fieldbus networks, motor control, and PLC systems.
What is the best drop-in replacement for ADM3050EBRWZ?
The ADM3050EBRWZ-RL is a tape-and-reel packaging variant of the same device and is a direct drop-in replacement. Other pin-compatible isolated CAN transceivers from Analog Devices, such as ADM3053, may also be considered, but verify pinout and specifications.
Can ADM3050EBRWZ replace ADM3053?
The ADM3053 is a different isolated CAN transceiver with integrated DC-DC converter, while the ADM3050E does not have an integrated converter. They are not pin-compatible, so replacement would require PCB redesign.
Where can I download the ADM3050EBRWZ datasheet PDF?
The ADM3050EBRWZ datasheet PDF can be downloaded from the Analog Devices website at https://www.analog.com/media/en/technical-documentation/data-sheets/ADM3050E.pdf. It is also available on distributor sites like DigiKey and Mouser.

工程參考資料,適用於 ADM3050EBRWZ — 比較、設計指引及合規資訊。

選型指南

Choose the ADM3050EBRWZ when you need a high-isolation (5.7 kV rms) CAN FD transceiver with support for data rates up to 12 Mbps. It is ideal for industrial, automotive, and building automation applications where galvanic isolation is critical. If you require a tape-and-reel packaging for automated assembly, select the ADM3050EBRWZ-RL variant. For extended temperature range applications, consider the ADM3050ETRWZ-EP-RL. If you need an integrated DC-DC converter to simplify power supply design, the ADM3053BRWZ is an alternative, but it is not pin-compatible and requires PCB redesign. For a cross-brand alternative, the ISO1042DW from Texas Instruments offers similar isolation and CAN FD support but with a lower maximum data rate of 5 Mbps.

與替代品比較

參數 本產品 ADM3050EBRWZ-RL ADM3050ETRWZ-EP-RL ISO1042DW
Package 16-SOIC 16-SOIC 16-SOIC 16-SOIC
Brand Analog Devices Analog Devices Analog Devices Texas Instruments
Isolation Voltage 5.7 kV rms 5.7 kV rms 5.7 kV rms 5.7 kV rms
Data Rate 12 Mbps 12 Mbps 12 Mbps 5 Mbps
Supply Voltage 5 V 5 V 5 V 3.3 V or 5 V
CAN FD Support Yes Yes Yes Yes
Integrated DC-DC Converter No No No No

主要差異化特點

  • Higher isolation voltage than many competitors (對比ISO1042DW)
  • CAN FD support up to 12 Mbps (對比ISO1042DW)
  • iCoupler technology integration (對比ADM3053BRWZ)

設計說明

For the ADM3050EBRWZ, ensure proper PCB layout with adequate creepage and clearance distances for the 5.7 kV rms isolation barrier. Maintain at least 8 mm creepage between the logic side and bus side to meet safety standards. Use a solid ground plane on each side of the isolation barrier and avoid routing traces across the barrier.

The ADM3050EBRWZ requires a 5V supply on both the logic side (VCC1) and the bus side (VCC2). Use separate power supplies or isolated DC-DC converters to maintain isolation. Decouple each supply pin with a 100 nF ceramic capacitor placed close to the pin, and a 10 uF bulk capacitor for transient currents.

Do not forget to connect the bus termination resistor (typically 120 ohms) at both ends of the CAN bus. The ADM3050EBRWZ does not include internal termination. Also, ensure the CANH and CANL lines are properly biased and that the bus is not left floating when the transceiver is disabled.

合規資訊

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
無鉛
Yes
無鹵
Unknown
衝突礦產
Unknown

RoHS compliant per distributor data. REACH and conflict minerals status not specified in provided data.

資料驗證日期: 2026-08-23 — 資料由 XAIPART 元件工程團隊驗證及整理

相關搜尋

ADM3050EBRWZ datasheet ADM3050EBRWZ price ADM3050EBRWZ buy ADM3050EBRWZ vs ADM3050ETRWZ-EP-RL isolated CAN transceiver 5.7kV CAN FD transceiver 12Mbps ADM3050EBRWZ pinout ADM3050EBRWZ replacement ADM3050EBRWZ SOIC-16 ADM3050EBRWZ industrial CAN what is the isolation voltage of ADM3050EBRWZ ADM3050EBRWZ in stock

相關元件與詞彙

Analog Devices ADM3050EBRWZ ADM3050EBRWZ-RL ADM3050ETRWZ-EP-RL ADM3053BRWZ ISO1042DW CAN transceiver CAN FD ISO 11898-2:2016 iCoupler 5.7 kV rms 12 Mbps SOIC-16 RoHS industrial automation motor control building automation EV charging medical equipment renewable energy
快速報價 RFQ
請填寫完整詳細資料 — 我們的業務團隊將於 24 小時內回覆
料號 製造商 封裝 QTY 目標價格 小計
✓
報價已提交!

我們將於 24 小時內回覆您的電子郵件

1
詢價已提交
2
已收到報價
3
已下單
4
付款
5
已出貨
6
已送達
檢視詢價單詳情