ADM3051BRWZ - High Speed Industrial CAN Transceiver | Analog Devices
MPN: ADM3051BRWZ ✓ 啟用中ADM3051BRWZ 概覽
A CAN transceiver is a physical layer device that interfaces between a CAN protocol controller and the differential bus lines (CANH and CANL). It converts the digital signals from the controller into differential signals for transmission over the twisted-pair bus and vice versa. The transceiver is a critical component in the CAN network hierarchy, which spans from the application layer down to the physical layer. The ADM3051BRWZ specifically implements the physical layer, providing the necessary drive strength, receiver sensitivity, and protection features required for robust communication in harsh industrial environments.
Key features of the ADM3051BRWZ include its compliance with ISO 11898, which ensures interoperability with other standard CAN devices. The device supports data rates up to 1 Mbps, making it suitable for high-speed industrial control applications. Its short-circuit protection on CANH and CANL against shorts to power or ground in 24 V systems enhances robustness in industrial settings where wiring faults are common. The slope control feature allows the designer to reduce electromagnetic interference (EMI) by controlling the slew rate of the output signals, which is particularly useful in applications with stringent EMC requirements. Thermal shutdown protection prevents damage from excessive power dissipation, and the low current standby mode reduces power consumption when the bus is idle.
From a technical perspective, the ADM3051BRWZ is designed to handle the electrical stresses of industrial environments. Its differential output voltage and receiver input sensitivity are optimized for reliable communication over long bus lengths (up to 1 km) and with many nodes. The device's common-mode input range accommodates ground potential differences between nodes, which is common in distributed systems. The transceiver's propagation delay and loop delay are carefully controlled to ensure timing compliance with the CAN protocol, even at 1 Mbps. The device also features a silent mode (via the RS pin) that disables the transmitter, allowing for bus monitoring without driving the bus.
Typical applications for the ADM3051BRWZ include industrial automation, building automation, automotive electronics (non-safety critical), and any system requiring robust CAN communication. In industrial automation, it is used in PLCs, sensors, and actuators to provide reliable data exchange over long distances. In building automation, it enables communication between HVAC controllers, lighting systems, and access control panels. The device's high-speed capability and robustness make it ideal for these applications.
When designing with the ADM3051BRWZ, it is important to consider proper bus termination (typically 120 ohms at each end) and to use twisted-pair cabling to minimize EMI. The slope control pin (RS) can be used to adjust the slew rate for EMI reduction, but this also limits the maximum data rate. For 1 Mbps operation, the slope control should be set to high-speed mode (RS connected to ground). Additionally, the VCC supply should be decoupled with a 100 nF capacitor close to the VCC pin to ensure stable operation.
直接替換替代品,適用於 ADM3051BRWZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ADM3051BRWZ (相同外形與佔位) — 差異在於 Package, Data Rate, Operating Temperature Range, RoHS Status, Short-Circuit Protection.
ADM3051BRWZ-REEL7
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3051BRWZ-REEL
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3051BRWZ-RL7
✅ 直接替換聯絡詢價
查看資料表 →ADM3051BRWZ-RL
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3051BRWZ-REEL7
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3051BRWZ-REEL
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3051BRWZ-RL7
✅ 直接替換聯絡詢價
查看資料表 →ADM3051BRWZ-RL
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3051BRWZ 規格
| Protocol | CAN |
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Supply Voltage (VCC) | 5 V |
| 資料速率 | 1 Mbps |
| Compliance | ISO 11898 |
| Number of Nodes | 110 or more |
| Short-Circuit Protection | CANH/CANL to power/ground in 24 V systems |
| Slope Control | Yes (RS pin) |
| 過熱關機 | Yes |
| Standby Mode | Low current |
| 封裝 | 14-lead SOIC (BRWZ) |
| 工作溫度範圍 | -40°C to +125°C |
| RoHS Compliant | Yes |
| 安裝類型 | Surface Mount |
ADM3051BRWZ 腳位配置
| 腳位 1 | TXD — Transmit data input |
| 腳位 2 | GND — Ground |
| 腳位 3 | VCC — Supply voltage (5 V) |
| 腳位 4 | RXD — Receive data output |
| 腳位 5 | RS — Slope control / standby mode |
| 腳位 6 | CANH — CAN high bus line |
| 腳位 7 | CANL — CAN low bus line |
| 腳位 8 | GND — Ground |
典型應用
ADM3051BRWZ 適用於 6 應用s: Industrial Automation, Building Automation, Automotive Electronics, Medical Equipment, Transportation Systems, Test and Measurement.
Industrial Automation
The ADM3051BRWZ is ideal for industrial automation networks where reliable, high-speed CAN communication is required. Its compliance with ISO 11898 and support for up to 1 Mbps data rates ensure robust data exchange between PLCs, sensors, and actuators. The device's short-circuit protection and wide operating temperature range (-40°C to +125°C) make it suitable for harsh factory floor environments. With the ability to connect 110 or more nodes, it supports large-scale automation systems. The slope control feature helps reduce EMI, which is critical in industrial settings with sensitive equipment. Overall, the ADM3051BRWZ provides the physical layer reliability needed for industrial control systems.
推薦
Building Automation
In building automation, the ADM3051BRWZ enables communication between HVAC controllers, lighting systems, and access control panels over a CAN bus. Its high-speed capability (1 Mbps) allows for quick response times in real-time control loops. The device's low current standby mode reduces power consumption when the bus is idle, contributing to energy efficiency. The robust protection features, including short-circuit protection and thermal shutdown, ensure long-term reliability in building environments. The ADM3051BRWZ's compliance with ISO 11898 ensures interoperability with other building automation devices. Its compact SOIC package is suitable for space-constrained controllers.
推薦
Automotive Electronics
The ADM3051BRWZ is suitable for non-safety-critical automotive applications such as body control modules, infotainment systems, and diagnostic interfaces. Its compliance with ISO 11898 ensures compatibility with standard automotive CAN networks. The device operates over a wide temperature range (-40°C to +125°C), making it suitable for under-hood and cabin environments. The short-circuit protection on CANH and CANL protects against wiring faults common in automotive harnesses. The slope control feature can be used to reduce EMI, which is important for meeting automotive EMC standards. The ADM3051BRWZ's high-speed capability supports the increasing data rates required by modern vehicles.
推薦
Medical Equipment
The ADM3051BRWZ can be used in medical equipment that requires reliable CAN communication, such as patient monitoring systems, diagnostic devices, and laboratory equipment. Its high-speed data rate (1 Mbps) ensures timely data transfer for real-time monitoring. The device's robust protection features, including short-circuit protection and thermal shutdown, enhance safety and reliability in medical environments. The wide operating temperature range allows operation in various clinical settings. The ADM3051BRWZ's compliance with ISO 11898 ensures interoperability with other medical devices using CAN. Its low power standby mode is beneficial for battery-powered portable medical devices.
推薦
Transportation Systems
The ADM3051BRWZ is used in transportation systems such as railway control, traffic management, and fleet management. Its high-speed capability (1 Mbps) supports real-time control and monitoring. The device's robustness, including short-circuit protection and wide temperature range, ensures reliable operation in outdoor and harsh environments. The ability to connect 110 or more nodes allows for large-scale networks in transportation infrastructure. The slope control feature helps reduce EMI, which is important in electrically noisy environments. The ADM3051BRWZ's compliance with ISO 11898 ensures compatibility with standard transportation communication protocols.
推薦
Test and Measurement
In test and measurement equipment, the ADM3051BRWZ provides reliable CAN communication for data acquisition and control. Its high-speed data rate (1 Mbps) enables fast data transfer, which is critical for accurate measurements. The device's low current standby mode reduces power consumption in portable instruments. The robust protection features ensure reliable operation in laboratory and field environments. The ADM3051BRWZ's compliance with ISO 11898 ensures compatibility with other test equipment using CAN. Its compact SOIC package is suitable for space-constrained designs.
推薦
推薦產品摘要
工程參考資料,適用於 ADM3051BRWZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADM3051BRWZ-REEL7 | ADM3051BRWZ-REEL | ADM3051BRWZ-RL7 | ADM3051BRWZ-RL |
|---|---|---|---|---|---|
| Package | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Data Rate | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V |
| ISO 11898 Compliance | Yes | Yes | Yes | Yes | Yes |
| Short-Circuit Protection | Yes | Yes | Yes | Yes | Yes |
| Slope Control | Yes | Yes | Yes | Yes | Yes |
| Operating Temperature Range | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C |
主要差異化特點
- High-speed CAN transceiver with 1 Mbps data rate (對比ADM3052BRWZ)
- Short-circuit protection on CANH and CANL against shorts to power/ground in 24 V systems (對比ADM3052BRWZ)
- Slope control for reduced EMI (對比ADM3052BRWZ)
設計說明
Place a 100 nF decoupling capacitor as close as possible to the VCC pin (pin 3) and ground. Additionally, a 10 µF bulk capacitor is recommended on the VCC rail to handle transient currents. The CANH and CANL lines should be routed as a differential pair with controlled impedance (typically 120 ohms) to minimize reflections and EMI. Keep the trace lengths short and avoid stubs to maintain signal integrity.
Use the slope control (RS pin) to adjust the slew rate of the CAN output signals. For high-speed operation (1 Mbps), connect RS to ground to select the high-speed mode. For lower data rates, a resistor from RS to ground can be used to reduce EMI. This is particularly important in applications with strict EMC requirements, such as automotive and industrial environments.
Ensure proper bus termination: place a 120 ohm resistor at each end of the CAN bus to match the characteristic impedance of the twisted-pair cable. Incorrect termination can cause signal reflections and communication errors. Also, avoid connecting more than 110 nodes without considering the total bus load and capacitance. The ADM3051BRWZ is not isolated; for applications requiring galvanic isolation, consider the ADM3052BRWZ or ADM3053BRWZ.
合規資訊
RoHS compliance is indicated in the datasheet. Other compliance details are not explicitly stated in the provided data.