An 8-bit microcontroller is a compact programmable controller that executes embedded firmware while integrating memory, digital I/O, communications peripherals, and timing functions on one semiconductor die. The AVR RISC architecture belongs to the broader hierarchy of microcontroller, embedded processor, and semiconductor devices. AT90CAN128 devices combine that general-purpose processing role with a dedicated CAN interface, allowing one controller to supervise distributed automotive, industrial, and instrumentation networks without a separate CAN controller.
The AT90CAN128 family combines 128 KB of in-system programmable flash with 4 KB of EEPROM for nonvolatile parameters and 4 KB of SRAM for working data. Its CAN controller supports CAN V2.0A and CAN V2.0B operation, while 53 I/O lines provide substantial connectivity for sensors, actuators, communications transceivers, and status indicators. The 15 MHz grade represented by AT90CAN128-15MZ is intended for applications requiring a 15 MHz clock rather than the 16 MHz AT90CAN128-16 variants.
The 64-QFN package uses a 9 mm by 9 mm body and an exposed thermal pad. That pad is important because it provides a direct path for heat transfer into the PCB rather than relying only on copper traces. Although the device includes substantial on-chip resources, package-pin multiplexing and external components determine how many I/O functions can be used simultaneously. Firmware, peripheral assignments, and board-level CAN transceiver selection remain central to a successful implementation.
Typical applications include CAN-based automotive body electronics, industrial machine controllers, vehicle diagnostics, building automation nodes, sensor gateways, and CAN-connected test equipment. The combination of 128 KB flash, integrated CAN, multiple serial interfaces, and a 64-pin package makes AT90CAN128 particularly useful where local control and reliable network communication must share one microcontroller.
PCB implementation should preserve the manufacturer's recommended power, decoupling, clock, programming, and exposed-pad arrangements. A CAN bus also requires a suitable 3.3 V or 5 V CAN transceiver, termination only at the two physical ends of the bus, and a carefully controlled common-mode environment. Firmware should verify reset behavior and bus error handling before enabling safety-relevant functions.
This page combines the manufacturer family specifications with practical application guidance, drop-in alternatives, package considerations, and design notes. It also distinguishes the 15 MHz AT90CAN128-15MZ from closely related 16 MHz and temperature-grade variants, helping engineers determine whether a board can reuse the same 64-QFN footprint and software configuration.
直接替換替代品,適用於 AT90CAN128-15MZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AT90CAN128-15MZ (相同外形與佔位) — 差異在於 Package, Mounting Type, Architecture, CAN Controller, Maximum Clock Frequency.
AT90CAN128-16MU
✅ 直接替換聯絡詢價
查看資料表 →AT90CAN128-16AU
✅ 直接替換聯絡詢價
查看資料表 →AT90CAN128-16AZ
✅ 直接替換📋 參考替代品(不在目錄中)
AT90CAN128-15MU
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AT90CAN128-15AU
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AT90CAN128-15MZ 最大額定值與電氣特性
| Microcontroller Type | 8-bit RISC microcontroller |
| Architecture | AVR RISC |
| 最大時脈頻率 | 15 MHz |
| Program Memory Type | ISP flash |
| Program Memory Size | 128 KB |
| EEPROM Size | 4 KB |
| SRAM Size | 4 KB |
| General-Purpose I/O Lines | 53 lines |
| General-Purpose Working Registers | 32 registers |
| CAN Controller Version | CAN V2.0A and CAN V2.0B |
| 封裝 | 64-QFN (9x9 mm) |
| Package Type | 64-VFQFN with exposed pad |
| Terminal Count | 64 terminals |
| 安裝類型 | No-lead surface mount |
| Temperature Grade | Automotive grade |
| USART Count | 2 serial interfaces |
| Timer and Counter Resources | Real-time counter and 4 flexible timer/counters |
AT90CAN128-15MZ 64-vfqfn with exposed pad 腳位配置指南
AT90CAN128-15MZ(64-vfqfn with exposed pad 封裝)的腳位配置。 此數位 IC 包含 GPIO、通訊介面(UART、SPI、I2C)與電源腳位。替代腳位功能與配置選項請參閱製造商資料表。對嵌入式系統設計與 PCB 佈局至關重要。
無詳細腳位定義資料: AT90CAN128-15MZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AT90CAN128-15MZ 適用於 6 應用s: Automotive Body Control Module, Vehicle Diagnostic Interface, Industrial CAN Sensor Gateway, Building Automation Controller, CAN-Connected Test Equipment, Robotics and Motion Control Node.
Automotive Body Control Module
AT90CAN128-15MZ fits an automotive body-control node that must process local sensor inputs while communicating on a CAN network. Its 8-bit AVR core runs at 15 MHz, while 53 general-purpose I/O lines support switches, lamps, actuators, and diagnostic signaling. The integrated CAN V2.0A/V2.0B controller reduces system complexity by avoiding a separate communication controller. With 128 KB of ISP flash, 4 KB of EEPROM, and 4 KB of SRAM, the device can retain calibration data and execute body-control software, although actual memory use and automotive qualification must be verified for the vehicle program.
推薦
Vehicle Diagnostic Interface
The AT90CAN128-15MZ is appropriate for a gateway or diagnostic interface that exchanges requests and status data over CAN while coordinating local I/O. The CAN V2.0A/V2.0B controller supports the bus protocol, and the two USARTs provide additional channels for service equipment or another embedded controller. Its 15 MHz AVR core and 128 KB program flash leave room for protocol handling, diagnostics, and application logic. Designers should confirm baud-rate tolerance, error recovery, bus termination, and transceiver selection against the vehicle network specification.
推薦
Industrial CAN Sensor Gateway
AT90CAN128-15MZ can consolidate sensors and actuators on a CAN segment in an industrial machine or production cell. Its 53 I/O lines accommodate digital inputs, outputs, and status signals, while the integrated CAN controller manages network communication without a separate protocol IC. The 15 MHz processing rate supports real-time control, and the four timer/counters, real-time timer, two USARTs, and SPI interface broaden the gateway's connectivity options. For harsh installations, verify the exact operating-temperature, EMC, isolation, surge, and grounding requirements rather than relying only on the automotive-grade suffix.
推薦
Building Automation Controller
The AT90CAN128-15MZ suits a building-network node that coordinates lighting, HVAC actuators, sensors, and service interfaces over CAN. Its 128 KB flash can hold communication and control firmware, while 4 KB of EEPROM is useful for configuration and operating counters. The 53 I/O lines offer broad discrete connectivity, and the real-time counter and timer/counters support periodic scheduling. A practical implementation should isolate field wiring, select a CAN transceiver matched to the bus voltage and topology, and validate brownout behavior so communication continues predictably during power transitions.
推薦
CAN-Connected Test Equipment
AT90CAN128-15MZ can serve as the embedded controller in a compact automated test system that receives commands and returns measurements over CAN. Its 15 MHz AVR core, four flexible timer/counters, and real-time counter support deterministic sequencing, while 53 I/O lines can operate relays, indicators, and measurement fixtures. The two USARTs and SPI interface allow connection to external converters or sensors. Designers should budget the 4 KB SRAM carefully, use the 128 KB flash for firmware rather than large captured data sets, and follow the manufacturer interface and decoupling guidance.
推薦
Robotics and Motion Control Node
The AT90CAN128-15MZ is well suited to a distributed robot controller that accepts commands over CAN and manages local sensors and actuators. Its timer/counters support timing-sensitive control functions, while 53 I/O lines can interface limit switches, encoders, indicators, and driver command signals. The CAN controller permits synchronized coordination with other robot modules, and 128 KB of flash accommodates layered control software. The design should account for motor-generated electrical noise, isolated communication needs, and the difference between control-loop timing and CAN message latency when selecting oscillators and external protection.
推薦
推薦產品摘要
工程參考資料,適用於 AT90CAN128-15MZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AT90CAN128-16MU | AT90CAN128-16AU | AT90CAN128-16AZ | AT90CAN128-15MU | AT90CAN128-15AU |
|---|---|---|---|---|---|---|
| Manufacturer | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 64-QFN (9x9 mm) | 64-QFN (9x9 mm) - same | 64-QFN (9x9 mm) - same | 64-QFN (9x9 mm) - same | 64-QFN (9x9 mm) - same | 64-QFN (9x9 mm) - same |
| Maximum Clock Frequency | 15 MHz | 16 MHz | 16 MHz | 16 MHz | 15 MHz | 15 MHz |
| Program Flash | 128 KB | 128 KB | 128 KB | 128 KB | 128 KB | 128 KB |
| EEPROM | 4 KB | 4 KB | 4 KB | 4 KB | 4 KB | 4 KB |
| SRAM | 4 KB | 4 KB | 4 KB | 4 KB | 4 KB | 4 KB |
| CAN Controller | CAN V2.0A/V2.0B | CAN V2.0A/V2.0B | CAN V2.0A/V2.0B | CAN V2.0A/V2.0B | CAN V2.0A/V2.0B | CAN V2.0A/V2.0B |
| General-Purpose I/O | 53 lines | 53 lines | 53 lines | 53 lines | 53 lines | 53 lines |
| Terminal Count | 64 terminals | 64 terminals | 64 terminals | 64 terminals | 64 terminals | 64 terminals |
| Suffix-Specific Grade | -15MZ automotive-grade ordering option | -16MU grade designation | -16AU grade designation | -16AZ grade designation | -15MU grade designation | -15AU grade designation |
主要差異化特點
- Exact 15 MHz AT90CAN128 configuration (對比AT90CAN128-16MU)
- Full AT90CAN128 memory and I/O resources (對比AT90CAN64-15MZ)
- Integrated CAN V2.0A/V2.0B controller (對比ATMEGA128A-MUR)
設計說明
Route the 64-QFN exposed pad onto a thermal and electrical land using the manufacturer's package drawing rather than treating it as an unspecified center pad. Keep power and ground connections short, place local decoupling capacitors at the relevant supply pins, and preserve the recommended via pattern for thermal performance. Confirm the PCB symbol against the official pin-description table before release because the exposed pad and numbered perimeter pins must be distinguished.
A CAN controller requires a physical-layer transceiver, so connect the AT90CAN128-15MZ CAN TX and RX pins to a suitably rated transceiver rather than directly to a bus. Use the transceiver's recommended logic levels and provide common-mode and surge protection appropriate to the installation. Terminate the bus at the two physical endpoints only, and keep the CAN route away from switching nodes and noisy motor return paths to reduce susceptibility to differential interference.
Do not assume that any same-package AT90CAN128 suffix is automatically interchangeable. Compare clock rating, temperature range, qualification markings, exposed-pad implementation, pin multiplexing, and reset or programming behavior. Moving from the 15 MHz target to a 16 MHz option changes the clock by 6.7%, so review baud-rate generation, timer constants, delay loops, and communication timing before approving the substitution.
Design the supply network for the exact operating-voltage range and current limits listed in the manufacturer datasheet, and include bulk and high-frequency decoupling near the device. Because this is a microcontroller rather than a power semiconductor, no safe-operating-area chart applies. Validate brownout, reset, and power-sequencing behavior with the CAN transceiver and external loads because unstable rails can appear as communication faults rather than obvious processor failures.
合規資訊
The component is identified as automotive grade, but exact RoHS, REACH, lead-free, halogen-free, conflict-minerals, and AEC-Q100 qualifications require confirmation from the exact Microchip ordering code.