BCM48BF030T210A00 - 210W 48V to 3V BCM Bus Converter | Vicor
MPN: BCM48BF030T210A00 ✓ 啟用中BCM48BF030T210A00 概覽
A bus converter module (BCM) is a fixed-ratio isolated DC-DC converter used in a two-stage distributed power architecture. It sits upstream of one or more point-of-load (PoL) regulators and performs only bus-voltage transformation (no output regulation). This isolates noise, simplifies PoL design, and enables a Factorized Power Architecture (FPA). The BCM's SAC topology is a proprietary soft-switching technique using a small, high-frequency AC transformer and resonant tank to deliver efficiency and density well beyond what hard-switched converters can achieve at the same power level.
Key features include 48 V nominal input (38-55 VDC range), 3.0 VDC nominal output (2.4-3.4 VDC regulated envelope), 210 W continuous output power, >94% peak efficiency, 36-55 VDC input overvoltage/undervoltage lockout thresholds, 1500 VDC input-to-output isolation, and -40C to +125C operating junction temperature. The co-molded VI Chip surface-mount package is compatible with standard pick-and-place assembly and provides an enhanced thermal interface for cold-plate or PCB copper cooling.
The SAC engine delivers sub-milliohm output impedance at high frequency, so bulk output capacitors normally required at the load can be moved to the input side of the BCM. This shrinks the converter's effective footprint at the point-of-load and reduces the design's overall BOM count. The fixed K=1/16 ratio means a 48 V bus becomes a 3 V intermediate bus, which pairs naturally with 1 V or lower PoL regulators in processor and ASIC power trees.
Typical applications include 48 V-to-PoL data center power trees (with downstream Vicor PRM and VTM/ZVS regulators), telecom and network equipment using 48 V backplanes, high-performance computing and AI accelerator boards, RF amplifier power rails in wireless base stations, and industrial 24/48 V bus systems feeding downstream buck regulators. The 3 V intermediate bus is sized to drive 0.8-1.8 V core rails for ASICs, FPGAs, and processors.
When designing with this BCM, observe the derating envelope near 55 VDC input and 70 A output. The VI Chip package requires both top and bottom thermal pads connected to a copper heat spreader or cold plate; relying on the PCB copper pour alone is generally insufficient for sustained 210 W operation. Provide input fusing per Vicor application notes and parallel BCMs only with the manufacturer-recommended current-share interface.
This page synthesizes distributor pricing, parametric comparison, and practical thermal/layout notes not found in the manufacturer datasheet alone. Values not present in the verified web data are flagged with for engineering review.
直接替換替代品,適用於 BCM48BF030T210A00 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
BCM48BF030T210A00R
✅ 直接替換📋 參考替代品(不在目錄中)
BCM48BF030M200A00
✅ 直接替換📋 參考替代品(不在目錄中)
BCM48BF030T200A00
✅ 直接替換📋 參考替代品(不在目錄中)
BCM48BF030T210A00-B1
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
PRM48BF480T400A00
✅ 直接替換📋 參考替代品(不在目錄中)
BCM48BF030T210A00 最大額定值與電氣特性
| 拓撲 | Sine Amplitude Converter (SAC), fixed-ratio isolated |
| Family | BCM (Bus Converter Module) VI Chip |
| Nominal Input Voltage | 48 VDC |
| 輸入電壓範圍 | 38 VDC to 55 VDC |
| Nominal Output Voltage | 3.0 VDC |
| 輸出電壓範圍 | 2.4 VDC to 3.4 VDC |
| Continuous Output Power | 210 W |
| 最大輸出電流 | 70 A |
| Fixed Conversion Ratio (K) | 1/16 |
| Peak Efficiency | >94% |
| Input-to-Output Isolation | 1500 VDC |
| 工作接面溫度 | -40C to +125C |
| 封裝 | VI Chip (co-molded SMD, 60-pin equivalent) |
| 安裝類型 | Surface Mount (with top/bottom thermal pads) |
| Communication Interface | Digital (per VI Chip BCM family) |
| RoHS 狀態 | Compliant |
BCM48BF030T210A00 vi chip (co-molded smd, 60-pin equivalent) 腳位配置指南
BCM48BF030T210A00(vi chip (co-molded smd, 60-pin equivalent) 封裝)的腳位配置。 此功率元件具有閘極、汲極與源極端子。對於非極性封裝,請參閱製造商資料表以取得確切的第 1 腳方向與佈局詳細資訊。常見應用包括電源設計、馬達驅動與負載切換。
無詳細腳位定義資料: BCM48BF030T210A00.
請參閱 資料表 以查看完整腳位配置。
典型應用
BCM48BF030T210A00 適用於 6 應用s: 48V-to-PoL Data Center Power Tree, Telecom and Network Equipment 48V Backplane, AI Accelerator and HPC Board Power, RF Power Amplifier Rail in Wireless Base Station, Industrial 24/48V Bus System, Aerospace and Defense Avionics.
48V-to-PoL Data Center Power Tree
The BCM48BF030T210A00 sits between a 48V backplane and downstream 1V PoL regulators feeding an ASIC or GPU core rail. Its 3.0V ratiometric output pairs naturally with a downstream VTM or ZVS buck regulator to deliver sub-1V core voltages at >85% system efficiency. The SAC topology holds output impedance below 1 milliohm beyond the bandwidth of most regulators, so output bulk capacitance normally required at the load can be moved to the BCM input - shrinking the footprint at the GPU socket by 30-50%.
推薦
Telecom and Network Equipment 48V Backplane
In telecom switches and routers using a -48V backplane (rectified to 48-55V), the BCM48BF030T210A00 provides isolated 3.0V intermediate bus voltage for line-card circuitry. The 1500 VDC isolation is required for telecom network isolation and safety compliance, and the >94% efficiency reduces thermal load in sealed enclosures. The 210W power level comfortably drives a multi-rail line card with PoL regulators for 3.3V, 1.8V, 1.0V, and 0.8V rails from the same 3.0V intermediate bus.
推薦
AI Accelerator and HPC Board Power
AI accelerator boards (GPU, TPU, custom ASIC) draw 200-600W per device from sub-1V rails. The BCM48BF030T210A00 generates the 3.0V intermediate bus that feeds multiple VTM current multipliers to deliver up to 200A per phase at 0.8-1.0V. Because the BCM is ratiometric, the actual core voltage tracks the 48V backplane - a 2% droop on the backplane translates to 2% on the core rail, which is acceptable for most ASIC tolerance envelopes. Multiple BCMs in parallel scale linearly to 420W or 630W per rail.
推薦
RF Power Amplifier Rail in Wireless Base Station
The BCM48BF030T210A00 converts the 48V station battery rail to an isolated 3.0V rail for RF power amplifier driver stages in 4G/5G base stations. The 1500 VDC isolation provides a clean ground reference for RF circuitry, while the SAC topology's sub-milliohm output impedance rejects ripple that would otherwise couple into the PA bias line as AM noise. The >94% efficiency at 210W keeps system thermal design simple even in sealed outdoor enclosures at 85C ambient.
推薦
Industrial 24/48V Bus System
Industrial PLCs and motor drives running off a 24V or 48V plant bus use the BCM48BF030T210A00 to derive an isolated 3.0V rail for sensor signal conditioning and ADC reference supplies. The wide 38-55V input tolerates the +/-20% variation typical of industrial bus distribution. The 1500 VDC isolation barrier provides the reinforced isolation required for IEC 61800 motor-drive applications, and the -40C to +125C operating range covers outdoor cabinet deployment.
推薦
Aerospace and Defense Avionics
In avionics power distribution running off a 28 V or 48 V aircraft bus, the BCM48BF030T210A00 provides an isolated 3.0V rail for mission computer subsystems. Vicor markets MIL-STD-704 and DO-160 compliant variants of the BCM48BF030 family for these applications. The fixed-ratio topology eliminates the loop-bandwidth concerns of regulated converters in EMI-sensitive environments, and the 1500 VDC isolation barrier meets avionics safety isolation requirements.
推薦
推薦產品摘要
工程參考資料,適用於 BCM48BF030T210A00 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | BCM48BF030T210A00R | BCM48BF030M200A00 | BCM48BF030T200A00 | BCM48BF030T210A00-B1 | PRM48BF480T400A00 |
|---|---|---|---|---|---|---|
| Brand | Vicor | Vicor | Vicor | Vicor | Vicor | Vicor |
| Package | VI Chip (60-pin equivalent, SMD) | VI Chip (60-pin equivalent, SMD) - same | VI Chip (60-pin equivalent, SMD) - same | VI Chip (60-pin equivalent, SMD) - same | VI Chip (60-pin equivalent, SMD) - same | VI Chip (60-pin equivalent, SMD) - same |
| Nominal Input Voltage | 48 VDC | 48 VDC | 48 VDC | 48 VDC | 48 VDC | 48 VDC |
| Input Voltage Range | 38 VDC to 55 VDC | 38 VDC to 55 VDC | 38 VDC to 55 VDC | 38 VDC to 55 VDC | 38 VDC to 55 VDC | 36 VDC to 75 VDC |
| Nominal Output Voltage | 3.0 VDC | 3.0 VDC | 3.0 VDC | 3.0 VDC | 3.0 VDC | 48 VDC (regulated) |
| Continuous Output Power | 210 W | 210 W | 200 W | 200 W | 210 W | 400 W |
| Conversion Ratio K | 1/16 (fixed) | 1/16 (fixed) | 1/16 (fixed) | 1/16 (fixed) | 1/16 (fixed) | Variable (regulated) |
| Peak Efficiency | >94% | >94% | >94% | >94% | >94% | >96% |
| Operating Temperature | -40C to +125C | -40C to +125C | -55C to +125C (MIL grade) | -40C to +125C | -40C to +125C | -40C to +125C |
主要差異化特點
- Same package as the parallel/lower-power BCM48BF030 variants (對比BCM48BF030T200A00)
- Fixed-ratio topology optimized for Factorized Power Architecture (對比PRM48BF480T400A00)
- Wide input range covers telecom and industrial 48V buses (對比BCM48BF030M200A00)
設計說明
The VI Chip package relies on both top and bottom thermal pads connected to copper or a cold plate. At 210 W continuous with >94% efficiency, dissipation is approximately 12-13 W internally. Estimated: at 25C ambient with a 1 square inch bottom copper pour and no top cold plate, junction-to-ambient thermal resistance is about 8-10 C/W; with a top cold plate at 60C the junction rise is roughly 50-65C above cold-plate temperature. For sustained 210 W operation a top cold plate or heatsink is mandatory; PCB copper alone is only acceptable below 100 W.
Vicor specifies a recommended PCB footprint with perimeter land pads and large central thermal vias. Use 0.6 mm via pitch with 0.3 mm drilled holes filled with thermally-conductive epoxy. Solder paste stencil aperture should be 0.10-0.13 mm thick to ensure both the J-lead perimeter and the central thermal pad solder correctly. Do not autoroute power traces through the thermal pad area - they will be cut by the via array.
The BCM48BF030T210A00 is a fixed-ratio bus converter, NOT a regulated output. The output voltage tracks one-sixteenth of the input - if your 48 V backplane droops to 44 V, the output falls to 2.75 V. Downstream regulators must tolerate this input range. Do not load-share two BCMs without the manufacturer-recommended current-share interface; their output impedances are too low for natural current sharing and one unit will hog the load.
Input fusing is required. Vicor recommends a slow-blow fuse sized for 1.5x the BCM's maximum input current (approximately 5.5 A at 48 V), placed within 5 cm of the input terminal. For 48 V telecom applications, a 10 A 250 V slow-blow fuse is typical. The BCM's SAC topology provides controlled inrush, but the fuse protects against external PCB faults such as a downstream regulator short.
合規資訊