BCM56990B0KFLGG - 25.6Tb/s Ethernet Switch | Broadcom
MPN: BCM56990B0KFLGG ✓ 啟用中BCM56990B0KFLGG 概覽
A multilayer Ethernet switch IC is a networking silicon device that forwards Layer 2 and Layer 3 packets at line rate, integrating MACs, SERDES, packet processors, and a host CPU interface into a single chip. Within the system hierarchy, the switch IC sits at the core of a switch platform, above PHYs and below system software such as a network operating system (NOS).
Key features of the BCM56990 include its 25.6-Tb/s switching capacity, which supports configurations such as 64 ports of 400GbE or high-count 100G/50G breakout modes; the related BCM56990 family member doubles the number of 50G ports from 32 to 64 and introduces 400GbE breakout support. The device integrates a PCIe Gen3 host interface that conforms to the PCIe Gen3 specification and also supports Gen1 and Gen2 operation at x1, x2, or x4 link widths, delivering up to 8.0 GT/s link speed (7.88 Gb/s data rate in each direction) for in-band or out-of-band host management connectivity.
Technically, the BCM56990 implements deep packet-buffering and multilayer forwarding architectures typical of Broadcom's StrataXGS switch families, enabling dense leaf/spine topologies, top-of-rack switching, and high-scale aggregation. The 8371-terminal LGA package requires a high-layer-count PCB with dense via-in-pad design and carefully engineered power delivery.
Typical applications include hyperscale data center switches, enterprise aggregation switches, white-box switch platforms, and storage networking appliances where 100G/400G port density and full multilayer (L2/L3) forwarding are required.
Design consideration: the higher-speed family variants require a higher-performance power delivery network and a faster reference clock (156.25 MHz versus 125 MHz), so clock tree and PDN design must be confirmed against the specific ordering part number before layout reuse.
This page synthesizes distributor availability, cross-reference guidance, and practical design notes not found in the manufacturer datasheet, providing engineers with a single citation-ready reference for the BCM56990B0KFLGG.
直接替換替代品,適用於 BCM56990B0KFLGG — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: BCM56990B0KFLGG (相同外形與佔位) — 差異在於 Mounting Type, Package Type, Product Family.
BCM56991B0KFLGG
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
BCM56990B0KFLGLG
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
BCM56990B0KFLG
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
BCM56990B0KFLGG 最大額定值與電氣特性
| Switching Capacity | 25.6 Tb/s |
| Product Family | BCM56990 multilayer switch |
| Device Type | 25.6-Tb/s Multilayer Ethernet Switch |
| Host Interface | PCIe Gen3 (conforms to PCIe Gen3 specification) |
| PCIe Compatibility | Gen1, Gen2, Gen3 |
| PCIe Link Widths | x1, x2, x4 |
| PCIe Link Speed | 8.0 GT/s (7.88 Gb/s data rate per direction) |
| Package Type | LGA (land grid array) |
| Number of Terminals | 8371 |
| Package Shape | Rectangular |
| Package Style | Grid array |
| Terminal Form | No lead |
| 安裝類型 | Surface Mount |
| Manufacturer | Broadcom Limited |
| Maximum Ports | Up to 64 x 400GbE (family capability) |
BCM56990B0KFLGG grid array 腳位配置指南
BCM56990B0KFLGG(grid array 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: BCM56990B0KFLGG.
請參閱 資料表 以查看完整腳位配置。
典型應用
BCM56990B0KFLGG 適用於 6 應用s: Hyperscale Data Center Leaf Switch, Top-of-Rack (ToR) 100G Switch, Enterprise Aggregation Switch, White-Box Switch Platform / ODM Design, Storage Networking / SAN Switch, Spine Switch for Leaf-Spine Fabrics.
Hyperscale Data Center Leaf Switch
The BCM56990B0KFLGG fits hyperscale leaf switch platforms because its 25.6-Tb/s switching capacity provides enough bandwidth for 64 x 400GbE or dense 100G breakout configurations in a single die, reducing chip count and simplifying platform BOM. In a typical leaf switch, the device terminates all server-facing and spine-facing SerDes lanes and performs full Layer 2/Layer 3 forwarding at line rate, while the PCIe Gen3 x4 host interface (7.88 Gb/s per direction) connects the management CPU running the network operating system. Because the family supports 400GbE breakout modes, operators can flexibly partition ports between 400G spine uplinks and 25G/50G server downlinks. The trade-off is a demanding 8371-terminal LGA land pattern and enhanced power delivery network, so the platform PCB must be designed for the device from the start.
推薦
Top-of-Rack (ToR) 100G Switch
For top-of-rack switching, the BCM56990B0KFLGG delivers the port density needed to aggregate dozens of servers on 25G/50G links while providing 100G and 400G uplinks, all within a single switch fabric device. Its multilayer forwarding supports both L2 bridging within the rack and L3 routing toward the spine, removing the need for external router silicon. The PCIe Gen3 interface, conforming to PCIe Gen3 with Gen1/Gen2 backward compatibility at x1/x2/x4 widths, attaches the BMC or host CPU for out-of-band management without a separate management Ethernet switch. Engineers should budget for the 156.25 MHz reference clock required by the higher-speed family configurations and place clock circuitry close to the device. Buffering and QoS resources on the die allow burst absorption typical of ToR traffic patterns.
推薦
Enterprise Aggregation Switch
In enterprise campus aggregation, the BCM56990B0KFLGG provides 25.6 Tb/s of non-blocking multilayer switching capacity to aggregate multiple access switches over 100G fiber links, with headroom for 400G upgrade paths enabled by the family's 400GbE breakout support. The device's L2/L3 feature set handles VLANs, routing, and QoS policies centrally, and the PCIe Gen3 host interface supports the control processor running enterprise network OS software. Compared with stacking multiple lower-capacity switch ICs, a single BCM56990-based aggregation platform lowers power per gigabit and simplifies software bring-up within the Broadcom StrataXGS software ecosystem. Platform designers must account for the 8371-terminal LGA assembly requirements and the enhanced power delivery network noted for this device generation.
推薦
White-Box Switch Platform / ODM Design
White-box and ODM switch platforms favor the BCM56990B0KFLGG because Broadcom StrataXGS switch silicon is supported by the majority of open network operating systems, letting ODMs reuse SDK integrations across generations. The 25.6-Tb/s capacity maps directly to common white-box configurations such as 64-port 400G or mixed 100G/50G breakout systems. The PCIe Gen3 x4 management interface (8.0 GT/s, 7.88 Gb/s per direction) is the standard attachment for the commodity x86 management CPU in these platforms. When migrating an existing ODM design from a prior family member, note that the BCM56990 requires a faster 156.25 MHz reference clock (versus 125 MHz) and a higher-performance power delivery network, so both the clock tree and PDN must be re-verified rather than copy-reused.
推薦
Storage Networking / SAN Switch
Storage area network switches benefit from the BCM56990B0KFLGG's deterministic line-rate multilayer forwarding and its 25.6-Tb/s capacity, which sustains dense 100G/400G ISL (inter-switch link) topologies between storage arrays and compute racks. Low-latency packet processing within the switch fabric helps meet the strict latency budgets of block-storage protocols carried over Ethernet fabrics. The PCIe Gen3 host interface provides a reliable control-plane path to the fabric management processor, supporting Gen1 through Gen3 for backward-compatible platform designs. Because storage platforms demand long field lifetimes, designers should qualify a same-family second source, such as the BCM56991 variant, during initial design to mitigate supply risk, while confirming identical land pattern and clock requirements from the Broadcom documentation.
推薦
Spine Switch for Leaf-Spine Fabrics
As a spine switch fabric, the BCM56990B0KFLGG concentrates uplinks from multiple leaf switches, where its 25.6-Tb/s capacity and 400GbE breakout support allow high-radix connectivity using fewer 400G lanes and breakout cables. Full Layer 3 forwarding at every spine port enables ECMP load balancing across the fabric without external routing silicon. The device's deep buffering absorbs incast bursts common in distributed storage and AI traffic patterns. Integration effort centers on the 8371-terminal LGA PCB breakout and the enhanced power delivery network required by this generation; Broadcom reference designs for the BCM56990 series should be followed for decoupling and layer stackup. The PCIe Gen3 management interface attaches the fabric controller in the standard x4 configuration.
推薦
推薦產品摘要
工程參考資料,適用於 BCM56990B0KFLGG — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | BCM56991B0KFLGG | BCM56990B0KFLGLG | BCM56990B0KFLG |
|---|---|---|---|---|
| Package | LGA-8371 (rectangular grid array, no lead) | LGA-8371 - same | LGA-8371 - same | LGA-8371 - same |
| Brand | Broadcom | Broadcom | Broadcom | Broadcom |
| Switching Capacity | 25.6 Tb/s | 25.6 Tb/s (higher-speed SKU) | 25.6 Tb/s | 25.6 Tb/s |
| Host Interface | PCIe Gen3 (Gen1/Gen2 compatible), x1/x2/x4 | PCIe Gen3 (Gen1/Gen2 compatible), x1/x2/x4 | PCIe Gen3 (Gen1/Gen2 compatible), x1/x2/x4 | PCIe Gen3 (Gen1/Gen2 compatible), x1/x2/x4 |
| Number of Terminals | 8371 | 8371 | 8371 | 8371 |
| 400GbE Breakout Support | Yes (family capability) | Yes | Yes (family) | Yes (family) |
| Price Tier (qty 1) | RFQ - not published | RFQ - not published | RFQ - not published | RFQ - not published |
主要差異化特點
- Doubled 50G port count (對比Prior BCM569xx family members)
- Native PCIe Gen3 host interface (對比Switch ICs requiring external management MAC/FPGA)
- Trade-off: stricter platform requirements (對比Earlier BCM569xx parts)
設計說明
The BCM56990 family requires a higher-performance power delivery network than prior generations, per distributor product information (IC-Components). With a 25.6-Tb/s SerDes fabric, core rail transient currents are large; design multi-phase VRM stages with bulk capacitance at the LGA die side and verify the power rail map against the Broadcom NDA datasheet before finalizing the PCB power plane stackup. Do not reuse the PDN from earlier BCM569xx generations without re-simulation, since rail count and current profiles differ.
The reference clock requirement changes across the family: the higher-performance variant uses 156.25 MHz versus 125 MHz on earlier parts. Confirm the required frequency for the exact orderable suffix before laying out the clock tree, and keep the clock source close to the device with a low-jitter (high-performance) oscillator suitable for multi-hundred-gigabit SerDes reference inputs. Clock jitter directly impacts the 25G/50G/100G SerDes bit-error performance on all 400GbE breakout lanes.
The 8371-terminal LGA package demands a high-layer-count PCB with via-in-pad breakout under the device. Follow Broadcom's package qualification and land pattern documentation for pad geometry and coplanarity-driven stencil design. Plan escape routing with at least one dedicated layer group for the PCIe Gen3 x4 management links (8.0 GT/s) and maintain controlled impedance per the PCIe Gen3 specification the interface conforms to. Recommend full signal-integrity simulation of the SerDes escape region prior to first spin.
A common migration error is assuming cross-family pin or clock compatibility: although the BCM56990 shares footprint characteristics with same-family variants, the clock (156.25 MHz vs 125 MHz) and PDN requirements changed in this generation. Always design to the full orderable part number BCM56990B0KFLGG, and re-verify land pattern, clock, and power tree when substituting any suffix variant. Broadcom gates the full datasheet behind NDA - obtain it before layout freeze.
合規資訊
Compliance data not published in the retrieved web sources; Broadcom product compliance documents should be requested from the manufacturer or distributor.