CS5521-ASZ - 16-Bit Dual-Channel ADC | Cirrus Logic | Industrial
MPN: CS5521-ASZ ✗ 停產CS5521-ASZ 概覽
An analog-to-digital converter converts continuous analog voltage signals into numerical values for processing, measurement, or control. The CS5521-ASZ belongs to the sigma-delta ADC family, which uses charge-balance conversion and digital filtering to provide high-resolution results from low-frequency or near-DC signals. Its integrated instrumentation amplifier can condition weak sensor outputs before conversion.
The device provides 16-bit nominal resolution, two analog inputs, and a 401 Hz conversion rate. A 32.768 kHz clock supports the conversion system, while operation from 3 V to 5 V allows use in both 3.3 V and 5 V powered equipment. The -40°C to +85°C temperature range supports industrial environments where extended temperature operation is valuable.
Digital filtering and continuous conversion suppress out-of-band noise and are especially useful with pressure, temperature, strain, and level sensors whose useful information changes slowly. The manufacturer describes the family as using charge-balance techniques to achieve 16-bit performance, with low input current and chopper-stabilized instrumentation amplifiers helping reduce input-related errors and sensitivity to low-level signals.
Typical applications include industrial process control, pressure and weight measurement, temperature sensing, bridge-sensor acquisition, and low-speed instrumentation. The two-channel architecture can monitor a primary sensor plus a reference or auxiliary channel, while the integrated gain stage reduces the need for separate analog front-end circuitry in suitable designs.
When implementing the converter, follow the manufacturer datasheet for analog grounding, reference connections, filter selection, and PCB layout. Input and digital return currents should be routed carefully to minimize conversion error. Confirm the complete pin assignment and exposed connection requirements before assembling a board because the exact device drawing must govern the layout.
This page combines the manufacturer family information, package and feature details, sourcing guidance, same-family alternatives, and practical application considerations to support faster component evaluation and PCB design planning.
直接替換替代品,適用於 CS5521-ASZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: CS5521-ASZ (相同外形與佔位) — 差異在於 Operating Temperature Range, Package.
CS5522-ASZ
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →CS5523-ASZ
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →CS5524-ASZ
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →CS5521-ASZ 最大額定值與電氣特性
| ADC Type | Sigma-delta ADC |
| 解析度 | 16 bit |
| Number of Analog Input Channels | 2 channels |
| Conversion Rate | 401 Hz |
| Clock Frequency | 32.768 kHz |
| Supply Voltage Range | 3 V to 5 V |
| Integrated Amplifier | Programmable-gain instrumentation amplifier |
| Conversion Architecture | Charge-balance sigma-delta |
| Input Multiplexer | 2-channel analog multiplexer |
| Digital Interface | SPI-compatible serial interface |
| Digital Filter | Built-in digital filter |
| FIFO | Integrated FIFO buffer |
| Calibration | Auto calibration |
| Power-On Reset | Power-on reset |
| Soft Reset | Supported |
| Input Range | Bipolar input |
| 工作溫度範圍 | -40°C to +85°C |
| 封裝 | 20-pin SSOP |
| 安裝類型 | Surface mount |
| RoHS 狀態 | Compliant |
CS5521-ASZ 20-pin ssop 腳位配置指南
CS5521-ASZ(20-pin ssop 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: CS5521-ASZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
CS5521-ASZ 適用於 6 應用s: Industrial Pressure Measurement, Bridge Sensor Signal Conditioning, Temperature and Level Monitoring, Process Control Instrumentation, Portable Environmental Monitoring, Precision Data Acquisition System.
Industrial Pressure Measurement
The CS5521-ASZ fits low-speed pressure acquisition because it combines a 16-bit dual-channel sigma-delta ADC, a 401 Hz conversion rate, and an integrated programmable-gain instrumentation amplifier. One channel can acquire the pressure transducer while the second can monitor a temperature or reference signal. Its 3 V to 5 V supply range and -40°C to +85°C operating range suit industrial instrumentation. The integrated low-input-current front end also reduces the amount of separate signal-conditioning circuitry required, although the complete gain, common-mode range, and excitation arrangement must be verified against the transducer and sensor bridge before schematic release.
推薦
Bridge Sensor Signal Conditioning
The CS5521-ASZ is appropriate for bridge-based load-cell, strain, and weight instrumentation because its integrated programmable-gain instrumentation amplifier can accept weak differential sensor signals while the 16-bit sigma-delta converter provides high nominal resolution. A 401 Hz conversion rate is suitable for many static-force and slowly changing mechanical measurements. Two channels allow the acquisition system to combine the active bridge output with a temperature, calibration, or reference measurement. The design should still account for bridge excitation, common-mode voltage, input protection, grounding, and digital-filter latency, with those conditions checked against the manufacturer application information.
推薦
Temperature and Level Monitoring
The dual-channel architecture of the CS5521-ASZ supports temperature probes, liquid-level sensors, and other slow-changing industrial signals where two measurements must be converted consistently. Its 16-bit nominal resolution provides detailed digital results, while the integrated amplifier can reduce the front-end signal chain for suitably conditioned inputs. The 32.768 kHz clock and 401 Hz conversion rate are appropriate for continuously updated process monitoring rather than high-bandwidth waveform acquisition. Designers should verify the sensor excitation scheme, input range, isolation requirements, and filtering latency to ensure that the converter is not asked to operate outside its specified analog conditions.
推薦
Process Control Instrumentation
The CS5521-ASZ can serve as the measurement front end in industrial process-control equipment where valve position, tank pressure, or another slow process variable must be digitized for a controller. Its dual inputs permit signal plus auxiliary-channel acquisition, and its integrated programmable-gain instrumentation amplifier helps preserve accuracy when the source signal is small. Operation across 3 V to 5 V supports both 3.3 V and 5 V system architectures, while the -40°C to +85°C range covers typical industrial environments. Final circuit design should include suitable analog grounding, reference treatment, input filtering, and separation between sensitive measurement paths and switching or digital circuitry.
推薦
Portable Environmental Monitoring
The CS5521-ASZ is suitable for compact environmental monitors that measure humidity, temperature, gas, or light through low-bandwidth analog sensors. Its dual inputs can acquire either two sensor channels or a sensor and internal reference, and the integrated gain stage can reduce board area by consolidating analog conditioning. A 3.3 V supply is compatible with the stated 3 V to 5 V operating range, making the converter appropriate for portable equipment powered by a rechargeable cell and regulator. Battery-operated designs must account for overall conversion and analog-front-end power, sensor excitation requirements, warm-up behavior, and whether the selected gain and conversion rate meet the application’s calibration and update-time goals.
推薦
Precision Data Acquisition System
The CS5521-ASZ suits laboratory and benchtop data-acquisition systems that require high nominal resolution rather than high sampling speed. Two analog inputs support differential or single-ended measurements through the integrated instrumentation-amplifier front end, while the sigma-delta architecture and built-in digital filter help reject noise outside the signal bandwidth. The 401 Hz conversion rate is well suited to temperature, pressure, force, and laboratory transducer measurements. For accurate results, the system designer should match input bandwidth to the digital-filter response, control analog grounding and reference noise, and avoid treating the nominal bit count as the complete error budget without considering offset, gain, noise, and calibration behavior.
推薦
推薦產品摘要
工程參考資料,適用於 CS5521-ASZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | CS5522-ASZ | CS5523-ASZ | CS5524-ASZ |
|---|---|---|---|---|
| Package | 20-pin SSOP | 20-pin SSOP | 20-pin SSOP | 20-pin SSOP |
| Brand | Cirrus Logic | Cirrus Logic | Cirrus Logic | Cirrus Logic |
| ADC Architecture | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta |
| Nominal Resolution | 16 bit | 24 bit | 16 bit | 24 bit |
| Analog Input Channels | 2 channels | 2 channels | 4 channels | 4 channels |
| Integrated Amplifier | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier | Programmable-gain instrumentation amplifier |
| Conversion Technique | Charge balance | Charge balance | Charge balance | Charge balance |
主要差異化特點
- Dual-channel precision conversion (對比CS5523-ASZ)
- 16-bit resolution aligned with dual-channel acquisition (對比CS5522-ASZ)
- Low-frequency measurement focus (對比CS5524-ASZ)
設計說明
Route sensitive analog inputs and the reference connection away from digital clock, SPI, and switching-supply return paths. Use the manufacturer layout and grounding guidance as the controlling reference. The 401 Hz conversion architecture reduces many high-frequency signal requirements, but input and reference traces can still pick up coupling that appears as measurement error. Keep the analog ground return continuous and evaluate the board’s digital return-current path before finalizing the component placement.
Do not select the external input network without checking the programmed gain, common-mode range, reference voltage, and internal filter response. The integrated instrumentation amplifier and built-in digital filter can reject out-of-band noise, but they do not remove the need for anti-alias filtering when sensor outputs contain higher-frequency content. Verify the selected gain and filter bandwidth against the required update rate, sensor impedance, and system calibration error.
Treat CS5521-ASZ and CS5521-ASZR as different orderable suffix variants rather than assuming identical reel presentation, and do not use either as a substitute for CS5522, CS5523, or CS5524 without reviewing resolution and channel count. Before assembly, confirm all 20 physical connections against the manufacturer pin table and verify that unused inputs are connected exactly as directed by the family documentation.
合規資訊