MPN: DS90CR583MTD ⚠ 最後購買機會DS90CR583MTD 概覽
An LVDS flat-panel-display link transmitter is an interface IC within the broader display-interface and semiconductor hierarchy. It accepts parallel logic-level pixel data, serializes that data onto low-voltage differential pairs, and transfers the resulting signal to a compatible receiver across a cable or PCB interconnect. By combining data and clock over controlled differential signaling, the interface reduces the number of conductors required compared with a parallel display bus while supporting higher signal integrity than ordinary single-ended transmission.
The DS90CR583 supports 28 CMOS/TTL input bits, four LVDS data outputs, and one LVDS clock output at a maximum signaling rate of 65 MHz. The 4.5 V minimum and 5.5 V maximum supply range suits conventional 5 V display-controller environments. The transmitter samples 28 input bits during every transmitted clock cycle, providing a straightforward mapping between the parallel source data and the serialized differential outputs.
The internal architecture includes parallel-to-serial conversion, clock generation, and a phase-locked transmit clock. The phase-locked clock is transmitted in parallel with the four data streams so that a compatible DS90CR584 receiver can reconstruct the original 28-bit word. This clock-and-data arrangement is important because display timing must remain aligned across every pixel-transfer cycle.
Typical applications include small-format TFT-LCD panels, industrial display controllers, medical diagnostic displays, test and measurement equipment, and legacy flat-panel systems that use FPD-Link or LVDS signaling. The transmitter is most appropriate where the host controller provides 28-bit parallel CMOS data and the display receiver supports the corresponding five-link LVDS architecture.
Designers should use controlled-impedance differential routing, maintain a continuous reference plane, and place bypass capacitors close to the supply pins. The TSSOP footprint requires careful fan-out because 56 leads provide limited routing escape area. Signal-pair length matching and separation from noisy switching nodes are essential for reliable LVDS operation.
This page consolidates the device architecture, interface requirements, lifecycle information, package characteristics, and application-specific design guidance into an engineering-focused reference for evaluating the DS90CR583MTD in legacy flat-panel-display systems.
直接替換替代品,適用於 DS90CR583MTD — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: DS90CR583MTD (相同外形與佔位) — 差異在於 Device Type, Protocol.
DS90CR583MTDX
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →DS90CR584MTD
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
DS90CR584MTDX
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →DS90CR583MTD
✅ 直接替換聯絡詢價
查看資料表 →DS90CR583
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
DS90CR583MTD 規格
| Product Type | LVDS flat-panel display link transmitter |
| 最大時脈頻率 | 65 MHz |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Input Data Width | 28 bits CMOS/TTL |
| LVDS Data Outputs | 4 differential streams |
| LVDS Clock Outputs | 1 differential stream |
| Total Driver Output Count | 5 differential outputs |
| Driver/Receiver Configuration | Transmitter |
| Protocol | FPD-Link / LVDS |
| 封裝 | 56-TSSOP |
| Package Width | 6.10 mm |
| Package Body Width | 0.240 inch |
| Packaging | Tube |
| 腳位數 | 56 pins |
| 安裝類型 | Surface mount |
DS90CR583MTD 0.240 inch 腳位配置指南
DS90CR583MTD(0.240 inch 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: DS90CR583MTD.
請參閱 資料表 以查看完整腳位配置。
典型應用
DS90CR583MTD 適用於 6 應用s: Legacy TFT-LCD Display Interfaces, Industrial Control Panel Displays, Medical Diagnostic Display Systems, Test and Measurement Equipment, Instrumentation and Process-Control HMIs, Point-of-Sale and Retail Terminals.
Legacy TFT-LCD Display Interfaces
The DS90CR583MTD fits a legacy TFT-LCD link when the display controller supplies 28 parallel CMOS/TTL bits and the panel uses the corresponding FPD-Link architecture. Its four 65 MHz LVDS data streams and separate phase-locked clock provide the serialized link expected by a compatible receiver. The 4.5 V to 5.5 V operating range matches a conventional 5 V display subsystem, while the 56-pin TSSOP supports compact controller boards. Use controlled-impedance routing for all five differential outputs and verify the panel's lane mapping, synchronization requirements, and supported clock rate before layout release.
推薦
Industrial Control Panel Displays
The DS90CR583MTD can support an industrial control panel that retains a 28-bit parallel display architecture but requires a low-voltage differential connection between the controller and display electronics. A 65 MHz maximum clock supports the stated FPD-Link operating point, and the five differential outputs separate payload data from the phase-locked clock. This arrangement is useful when cable length, noise immunity, or connector pin count makes a wide parallel bus undesirable. Industrial use still requires confirmation of temperature rating, qualification status, panel timing, and long-term availability before production commitment.
推薦
Medical Diagnostic Display Systems
The DS90CR583MTD is appropriate for a medical diagnostic display subsystem when the host controller provides 28 parallel data bits and the monitor accepts an LVDS FPD-Link signal. Differential data streams can reduce sensitivity to common-mode noise and make the interface less susceptible to ground-offset problems than a comparable single-ended parallel bus. The transmitter's four data outputs and dedicated clock provide deterministic organization of each 28-bit transfer. Medical-system design work must additionally verify electrical-safety requirements, applicable qualification, temperature limits, display validation, and the system risk controls required for the intended use.
推薦
Test and Measurement Equipment
The DS90CR583MTD can be used in test and measurement equipment that includes a legacy flat-panel display controller requiring an LVDS transmitter. Its 28-bit parallel input and 65 MHz maximum link rate accommodate panel-controller designs built around the DS90CR583/DS90CR584 FPD-Link family, while the dedicated phase-locked clock helps the receiving side maintain a consistent sampling relationship. In instrumentation, placement and return-path control are important because display circuitry may sit near switching converters, motor drivers, or high-current relay networks. Keep the LVDS pairs away from those sources and provide a stable reference plane beneath the link.
推薦
Instrumentation and Process-Control HMIs
The DS90CR583MTD is suited to a human-machine interface where a local controller drives a panel over LVDS instead of routing a wide parallel bus through a larger system. The 28-bit input structure maps directly to a typical color display data path, while four differential data outputs and one clock output provide a compact cable interface. A 5 V supply requirement keeps integration straightforward for controllers that already include 5 V power. Designers should verify the receiving display's supported resolution and refresh rate, implement matched differential routing, and provide local decoupling close to the transmitter to limit conducted noise entering the display link.
推薦
Point-of-Sale and Retail Terminals
The DS90CR583MTD can support a point-of-sale terminal or retail display controller that retains a 28-bit parallel video source and requires a compact differential connection to a remote LCD panel. Sending the 28-bit payload across four LVDS data lanes plus a clock reduces conductor demand and can improve noise immunity within the enclosure. The device's 4.5 V to 5.5 V range supports integration with 5 V display electronics, and its 65 MHz maximum rate matches the stated FPD-Link class. Before deployment, confirm the panel's timing interface, temperature requirements, cable characteristics, and continuing supply status.
推薦
推薦產品摘要
工程參考資料,適用於 DS90CR583MTD — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | DS90CR583MTDX | DS90CR584MTD | DS90CR584MTDX | DS90CR583MTD | DS90CR583 |
|---|---|---|---|---|---|---|
| Package | 56-TSSOP | 56-TSSOP | 56-TSSOP | 56-TSSOP | 56-TSSOP | 56-TSSOP |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Function | FPD-Link transmitter | FPD-Link transmitter | FPD-Link receiver | FPD-Link receiver | FPD-Link transmitter | FPD-Link transmitter |
| Maximum Clock Frequency | 65 MHz | 65 MHz | 65 MHz | 65 MHz | 65 MHz | 65 MHz |
| Supply Voltage Range | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V |
| Parallel Input Width | 28 bits CMOS/TTL | 28 bits CMOS/TTL | 28 bits CMOS/TTL receiver output | 28 bits CMOS/TTL receiver output | 28 bits CMOS/TTL | 28 bits CMOS/TTL |
| LVDS Data Channels | 4 | 4 | 4 receiver inputs | 4 receiver inputs | 4 | 4 |
| Clock Channel | 1 phase-locked transmit-clock output | 1 phase-locked transmit-clock output | 1 phase-locked receive-clock output | 1 phase-locked receive-clock output | 1 phase-locked transmit-clock output | 1 phase-locked transmit-clock output |
| Protocol | FPD-Link / LVDS | FPD-Link / LVDS | FPD-Link / LVDS | FPD-Link / LVDS | FPD-Link / LVDS | FPD-Link / LVDS |
| Original Manufacturer | National Semiconductor | National Semiconductor | National Semiconductor | National Semiconductor | National Semiconductor | National Semiconductor |
主要差異化特點
- Direct 28-bit parallel-to-LVDS serialization (對比DS90CR584MTD)
- Dedicated phase-locked clock channel (對比DS90CR584MTDX)
- Established 65 MHz FPD-Link architecture (對比DS90CR583)
設計說明
Route all LVDS pairs as tightly coupled differential nets with a continuous reference plane directly beneath them. Maintain equal intra-pair spacing and matched length where the interconnect topology requires it. Avoid plane splits, test-point stubs, and unnecessary layer transitions because those discontinuities can degrade the 65 MHz signal. Keep the parallel CMOS/TTL inputs away from the LVDS outputs to reduce crosstalk into the serialized link.
Place supply bypass capacitors close to the device's supply and ground pins, and provide a low-impedance ground-plane connection for every ground lead. The 56-pin TSSOP has limited escape space, so plan fan-out before fixing the component orientation. Confirm pin-1 location, pin numbering, and exposed pad treatment against the manufacturer pin-description table; do not infer connections solely from the package dimensions.
Preserve the phase relationship between the four data links and the dedicated clock link by using consistent trace geometry and avoiding unrelated high-speed activity near these nets. If the link traverses a cable or connector, specify controlled impedance and validate the complete transmitter-to-receiver path. The transmitter supports up to 65 MHz, but usable link margin also depends on loss, skew, noise, and the receiving display.
Do not interchange the DS90CR583 transmitter with a DS90CR584 receiver on the assumption that their shared family name makes them equivalent. The transmitter accepts parallel CMOS/TTL data and creates the LVDS streams, while the receiver performs the opposite function. Also verify the exact ordering suffix, temperature grade, package orientation, and lifecycle requirements before rebuilding a last-time-buy assembly.
合規資訊
The available manufacturer and distributor records do not state the requested compliance statuses for this ordering code. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification documentation before regulated deployment.