ICL7106CPL+3 - 3.5-Digit LCD ADC | Analog Devices
MPN: ICL7106CPL+3 ✓ 啟用中ICL7106CPL+3 概覽
An integrated A/D converter such as the ICL7106CPL+3 converts an analog input voltage into a digital code suitable for direct panel display. Within the ADC and data-acquisition hierarchy, it is a display-oriented integrating converter rather than a high-speed sampled ADC. Its true-differential input and reference arrangement support ratiometric measurements of resistance, resistance bridges, and other transducers where excitation drift and reference variation can be canceled.
The principal feature is integrated display control. The ICL7106CPL+3 includes seven-segment decoders, digit drivers, segment drivers, polarity drive, a voltage reference, and a clock circuit. This integration removes the need for external display multiplexers or driver ICs. The 3.5-digit resolution supports panel readings from 000 to 999 plus overrange indication, while the 40-pin PDIP package provides through-hole compatibility for laboratory, panel-meter, and industrial instrumentation designs.
The conversion system uses dual-slope integration, as identified in the ICL7106 documentation. Dual-slope operation averages the unknown input over a defined integration interval and compares the result with a reference, reducing sensitivity to periodic interference when the measurement is synchronized appropriately. The converter also includes a zero-integrator phase that eliminates overrange hangover and hysteresis effects identified by Analog Devices.
Typical uses include digital panel meters, laboratory meters, temperature indicators, weighing displays, resistance-measurement instruments, and ratiometric bridge or transducer readouts. The device is especially useful where the measured value must appear directly on a non-multiplexed LCD and where a complete display subsystem is required without adding a separate microcontroller and display driver.
When designing the circuit, follow the manufacturer's input, reference, clock, power, and LCD connection guidance exactly. Preserve the specified input impedance and reference arrangement, route sensitive analog and reference nets away from display drive traces, and account for LCD segment capacitance when selecting timing and PCB routing. Verify that the selected display uses the expected segment and polarity drive arrangement.
This page combines manufacturer product information, cross-reference findings, application guidance, and engineering-focused selection criteria. It highlights where ICL7106CPL+3 is appropriate, how its integrated LCD-driver architecture reduces external circuitry, and which documented alternatives share the 40-pin PDIP footprint for replacement planning.
直接替換替代品,適用於 ICL7106CPL+3 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ICL7106CPL+3 (相同外形與佔位) — 差異在於 Converter Architecture, Display Output, Integrated Clock, Integrated Reference.
ICL7106CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7106CPL-3
✅ 直接替換📋 參考替代品(不在目錄中)
ICL7106CPLZ
✅ 直接替換📋 參考替代品(不在目錄中)
ICL7106CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7106CPL+3 最大額定值與電氣特性
| Product Type | 3.5-digit LCD display A/D converter |
| Converter Architecture | Dual-slope A/D conversion |
| Measurement Resolution | 3.5 digits |
| Display Output | 7-segment LCD |
| Display Drive Method | Direct, non-multiplexed LCD drive |
| Input Configuration | True differential input |
| Integrated Reference | Internal voltage reference |
| Integrated Clock | Internal clock circuit |
| Integrated Functions | Seven-segment decoders, display drivers, polarity drive, reference, and clock |
| 封裝 | 40-pin PDIP |
| Package Body Width | 0.600 in (15.24 mm) |
| 安裝類型 | Through-hole DIP |
| Overrange Behavior | Zero-integrator phase eliminates overrange hangover and hysteresis effects |
| Production Status | Production |
ICL7106CPL+3 0.600 in (15.24 mm) 腳位配置指南
ICL7106CPL+3(0.600 in (15.24 mm) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ICL7106CPL+3.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICL7106CPL+3 適用於 6 應用s: Digital Panel Meters, Laboratory Digital Multimeters, Resistance and Bridge Measurement, Temperature and Process Indicators, Weighing and Load Indicator Displays, Educational and Service Instrumentation.
Digital Panel Meters
The ICL7106CPL+3 fits standalone digital panel meters because it combines a 3.5-digit A/D converter with seven-segment decoding, polarity drive, digit drivers, segment drivers, a reference, and a clock in one 40-pin PDIP device. Connect the measured analog signal to the true-differential input and route the converter outputs to a compatible non-multiplexed LCD. This integration eliminates a separate display-driver IC and reduces the number of interconnects that could introduce noise. The main trade-off is that the DIP footprint is larger than a surface-mount equivalent, but it remains convenient for instruments assembled through holes and easy to prototype, inspect, service, or replace.
Laboratory Digital Multimeters
The ICL7106CPL+3 is appropriate for a laboratory meter that displays resistance, voltage, or another slow-moving measurement directly on an LCD. Its 3.5-digit dual-slope conversion, true-differential input, internal reference, and internal clock provide the core measurement functions without requiring a separate display controller. The differential arrangement is particularly useful when the source and reference share an excitation path, enabling ratiometric behavior. For laboratory use, follow the manufacturer input and reference recommendations, use a stable display assembly, and isolate sensitive analog traces from LCD drive outputs to preserve measurement repeatability.
Resistance and Bridge Measurement
The ICL7106CPL+3 can support resistance, strain-bridge, and other ratiometric transducer measurements because its true-differential input and reference channels complement an excitation source. When the reference tracks the sensor excitation, common supply or excitation drift can be reduced, improving the usefulness of the displayed ratio. The device performs the conversion and directly drives a non-multiplexed seven-segment LCD, so the instrument does not need a separate display-driver stage. Select external sensitivity, excitation, and reference components according to the manufacturer guidance, and verify common-mode range and settling behavior for the actual bridge impedance.
Temperature and Process Indicators
The ICL7106CPL+3 is well matched to temperature indicators and industrial process readouts that need a stable numerical display rather than rapid sampling. A sensor interface can produce a differential voltage proportional to temperature, while the converter handles integration, decoding, and LCD drive. The internal clock and reference simplify the peripheral circuit, and the zero-integrator phase avoids the overrange hangover and hysteresis identified by the manufacturer. Keep the sensor path away from display-drive traces, provide stable decoupling at the supply pins, and choose the LCD and segment timing to match the non-multiplexed drive architecture.
Weighing and Load Indicator Displays
The ICL7106CPL+3 can form the measurement and display core of a compact weighing system because a load-cell bridge can be measured with differential excitation and reference connections. Its 3.5-digit readout is appropriate for basic commercial or laboratory scales, while the integrated display functions produce a direct numerical result without a separate LED or LCD driver. The dual-slope architecture favors stable readings under relatively slow measurement conditions. A practical design must use a suitable low-noise excitation source, protect the high-impedance input path, and account for the limited number of digits when specifying the scale's resolution and overload indication.
Educational and Service Instrumentation
The ICL7106CPL+3 is useful in educational meters and service instrumentation because one readable 40-pin DIP combines the converter and direct LCD drive. Students or technicians can inspect a complete signal chain from differential input through seven-segment decoding and display output without a microcontroller or complex display bus. The through-hole package also supports breadboard, educational, and repair-oriented assemblies where socketed DIP construction is convenient. To reproduce reliable results, follow the official grounding and decoupling guidance, use a compatible non-multiplexed display, and ensure that measurement speed and input impedance remain suitable for the source being tested.
工程參考資料,適用於 ICL7106CPL+3 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ICL7106CPL+ | ICL7106CPL-3 | ICL7106CPLZ | ICL7106CPL |
|---|---|---|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Renesas Electronics | Renesas Electronics |
| Product Type | 3.5-digit LCD display A/D converter | 3.5-digit LCD display A/D converter | 3.5-digit LCD display A/D converter | 3.5-digit LCD display A/D converter | 3.5-digit LCD display A/D converter |
| Measurement Resolution | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits |
| Conversion Architecture | Dual-slope | Dual-slope | Dual-slope | Dual-slope | Dual-slope |
| Display Type | 7-segment LCD | 7-segment LCD | 7-segment LCD | 7-segment LCD | 7-segment LCD |
| Input Configuration | True differential | True differential | True differential | True differential | True differential |
| Display Drive | Direct non-multiplexed LCD | Direct non-multiplexed LCD | Direct non-multiplexed LCD | Direct non-multiplexed LCD | Direct non-multiplexed LCD |
| Integrated Clock | Yes | Yes | Yes | Yes | Yes |
主要差異化特點
- Complete display subsystem in one converter IC (對比ICL7106CPL)
- True-differential measurement architecture (對比ICL7106CPLZ)
- Direct drive for non-multiplexed LCDs (對比ICL7107CPL)
設計說明
Route the true-differential input and reference as a compact, matched pair, and keep them away from the LCD segment and digit-drive traces. The converter contains high-impedance measurement and reference paths, while display outputs carry switched capacitive loads. Preserving spatial separation reduces coupling from display activity into the measured value. Place the input and reference components close to the relevant device pins and provide a quiet ground-return path according to the manufacturer's layout example.
Use the manufacturer's supply, decoupling, and grounding recommendations exactly because this DIP device combines sensitive analog conversion with relatively high-current LCD drive. Place the principal bypass capacitor close to the supply pins and keep display-current returns from sharing the same narrow path as the analog reference. Check capacitor voltage rating, polarity, temperature coefficient, and effective capacitance at the operating frequency. A stable supply is especially important when the reference establishes the conversion ratio.
Do not assume that every ICL7106 ordering code is interchangeable merely because the packages match. Validate suffix-specific temperature grade, marking, lifecycle status, supply limits, and timing against the manufacturer ordering information. Also verify that the chosen LCD is non-multiplexed and has the expected segment and polarity arrangement. The ICL7107CPL family is not a direct substitute when the PCB requires LCD drive rather than the corresponding LED-display outputs.
Treat the analog input and reference as high-impedance measurement nodes, and avoid long parallel copper runs next to LCD outputs. Connect sensor excitation and reference paths so common-mode variation is rejected by the differential input. If measuring a slow bridge or resistive sensor, keep connector and wiring leakage small relative to the intended source impedance. Validate settling and noise at the actual source impedance rather than relying only on the converter's headline resolution.
合規資訊
The Analog Devices product page identifies the ICL7106 family as production. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals statements were not identified for this exact ordering code.