ICL7106CPL+3 - 3.5-Digit LCD ADC | Analog Devices
N.º da peça: ICL7106CPL+3 ✓ AtivoICL7106CPL+3 Visão geral
An integrated A/D converter such as the ICL7106CPL+3 converts an analog input voltage into a digital code suitable for direct panel display. Within the ADC and data-acquisition hierarchy, it is a display-oriented integrating converter rather than a high-speed sampled ADC. Its true-differential input and reference arrangement support ratiometric measurements of resistance, resistance bridges, and other transducers where excitation drift and reference variation can be canceled.
The principal feature is integrated display control. The ICL7106CPL+3 includes seven-segment decoders, digit drivers, segment drivers, polarity drive, a voltage reference, and a clock circuit. This integration removes the need for external display multiplexers or driver ICs. The 3.5-digit resolution supports panel readings from 000 to 999 plus overrange indication, while the 40-pin PDIP package provides through-hole compatibility for laboratory, panel-meter, and industrial instrumentation designs.
The conversion system uses dual-slope integration, as identified in the ICL7106 documentation. Dual-slope operation averages the unknown input over a defined integration interval and compares the result with a reference, reducing sensitivity to periodic interference when the measurement is synchronized appropriately. The converter also includes a zero-integrator phase that eliminates overrange hangover and hysteresis effects identified by Analog Devices.
Typical uses include digital panel meters, laboratory meters, temperature indicators, weighing displays, resistance-measurement instruments, and ratiometric bridge or transducer readouts. The device is especially useful where the measured value must appear directly on a non-multiplexed LCD and where a complete display subsystem is required without adding a separate microcontroller and display driver.
When designing the circuit, follow the manufacturer's input, reference, clock, power, and LCD connection guidance exactly. Preserve the specified input impedance and reference arrangement, route sensitive analog and reference nets away from display drive traces, and account for LCD segment capacitance when selecting timing and PCB routing. Verify that the selected display uses the expected segment and polarity drive arrangement.
This page combines manufacturer product information, cross-reference findings, application guidance, and engineering-focused selection criteria. It highlights where ICL7106CPL+3 is appropriate, how its integrated LCD-driver architecture reduces external circuitry, and which documented alternatives share the 40-pin PDIP footprint for replacement planning.
Alternativas drop-in para ICL7106CPL+3 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com ICL7106CPL+3 (mesmo formato e footprint) — diferindo em Converter Architecture, Display Output, Integrated Clock, Integrated Reference.
ICL7106CPL+
✅ Drop-InConsulte o preço
Ver ficha técnica →ICL7106CPL-3
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
ICL7106CPLZ
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
ICL7106CPL+
✅ Drop-InConsulte o preço
Ver ficha técnica →ICL7106CPL+3 Classificações máximas e características elétricas
| Product Type | 3.5-digit LCD display A/D converter |
| Converter Architecture | Dual-slope A/D conversion |
| Measurement Resolution | 3.5 digits |
| Display Output | 7-segment LCD |
| Display Drive Method | Direct, non-multiplexed LCD drive |
| Input Configuration | True differential input |
| Integrated Reference | Internal voltage reference |
| Integrated Clock | Internal clock circuit |
| Integrated Functions | Seven-segment decoders, display drivers, polarity drive, reference, and clock |
| Encapsulamento | 40-pin PDIP |
| Package Body Width | 0.600 in (15.24 mm) |
| Tipo de montagem | Through-hole DIP |
| Overrange Behavior | Zero-integrator phase eliminates overrange hangover and hysteresis effects |
| Production Status | Production |
Guia de Configuração de Pinos do ICL7106CPL+3 0.600 in (15.24 mm)
Configuração de pinos para ICL7106CPL+3 (pacote 0.600 in (15.24 mm)). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para ICL7106CPL+3.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
ICL7106CPL+3 é adequado para 6 aplicaçãos: Digital Panel Meters, Laboratory Digital Multimeters, Resistance and Bridge Measurement, Temperature and Process Indicators, Weighing and Load Indicator Displays, Educational and Service Instrumentation.
Digital Panel Meters
The ICL7106CPL+3 fits standalone digital panel meters because it combines a 3.5-digit A/D converter with seven-segment decoding, polarity drive, digit drivers, segment drivers, a reference, and a clock in one 40-pin PDIP device. Connect the measured analog signal to the true-differential input and route the converter outputs to a compatible non-multiplexed LCD. This integration eliminates a separate display-driver IC and reduces the number of interconnects that could introduce noise. The main trade-off is that the DIP footprint is larger than a surface-mount equivalent, but it remains convenient for instruments assembled through holes and easy to prototype, inspect, service, or replace.
Laboratory Digital Multimeters
The ICL7106CPL+3 is appropriate for a laboratory meter that displays resistance, voltage, or another slow-moving measurement directly on an LCD. Its 3.5-digit dual-slope conversion, true-differential input, internal reference, and internal clock provide the core measurement functions without requiring a separate display controller. The differential arrangement is particularly useful when the source and reference share an excitation path, enabling ratiometric behavior. For laboratory use, follow the manufacturer input and reference recommendations, use a stable display assembly, and isolate sensitive analog traces from LCD drive outputs to preserve measurement repeatability.
Resistance and Bridge Measurement
The ICL7106CPL+3 can support resistance, strain-bridge, and other ratiometric transducer measurements because its true-differential input and reference channels complement an excitation source. When the reference tracks the sensor excitation, common supply or excitation drift can be reduced, improving the usefulness of the displayed ratio. The device performs the conversion and directly drives a non-multiplexed seven-segment LCD, so the instrument does not need a separate display-driver stage. Select external sensitivity, excitation, and reference components according to the manufacturer guidance, and verify common-mode range and settling behavior for the actual bridge impedance.
Temperature and Process Indicators
The ICL7106CPL+3 is well matched to temperature indicators and industrial process readouts that need a stable numerical display rather than rapid sampling. A sensor interface can produce a differential voltage proportional to temperature, while the converter handles integration, decoding, and LCD drive. The internal clock and reference simplify the peripheral circuit, and the zero-integrator phase avoids the overrange hangover and hysteresis identified by the manufacturer. Keep the sensor path away from display-drive traces, provide stable decoupling at the supply pins, and choose the LCD and segment timing to match the non-multiplexed drive architecture.
Weighing and Load Indicator Displays
The ICL7106CPL+3 can form the measurement and display core of a compact weighing system because a load-cell bridge can be measured with differential excitation and reference connections. Its 3.5-digit readout is appropriate for basic commercial or laboratory scales, while the integrated display functions produce a direct numerical result without a separate LED or LCD driver. The dual-slope architecture favors stable readings under relatively slow measurement conditions. A practical design must use a suitable low-noise excitation source, protect the high-impedance input path, and account for the limited number of digits when specifying the scale's resolution and overload indication.
Educational and Service Instrumentation
The ICL7106CPL+3 is useful in educational meters and service instrumentation because one readable 40-pin DIP combines the converter and direct LCD drive. Students or technicians can inspect a complete signal chain from differential input through seven-segment decoding and display output without a microcontroller or complex display bus. The through-hole package also supports breadboard, educational, and repair-oriented assemblies where socketed DIP construction is convenient. To reproduce reliable results, follow the official grounding and decoupling guidance, use a compatible non-multiplexed display, and ensure that measurement speed and input impedance remain suitable for the source being tested.
Dados de referência de engenharia para ICL7106CPL+3 — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | ICL7106CPL+ | ICL7106CPL-3 | ICL7106CPLZ | ICL7106CPL |
|---|---|---|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Renesas Electronics | Renesas Electronics |
| Product Type | 3.5-digit LCD display A/D converter | 3.5-digit LCD display A/D converter | 3.5-digit LCD display A/D converter | 3.5-digit LCD display A/D converter | 3.5-digit LCD display A/D converter |
| Measurement Resolution | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits |
| Conversion Architecture | Dual-slope | Dual-slope | Dual-slope | Dual-slope | Dual-slope |
| Display Type | 7-segment LCD | 7-segment LCD | 7-segment LCD | 7-segment LCD | 7-segment LCD |
| Input Configuration | True differential | True differential | True differential | True differential | True differential |
| Display Drive | Direct non-multiplexed LCD | Direct non-multiplexed LCD | Direct non-multiplexed LCD | Direct non-multiplexed LCD | Direct non-multiplexed LCD |
| Integrated Clock | Yes | Yes | Yes | Yes | Yes |
Principais diferenciais
- Complete display subsystem in one converter IC (vs ICL7106CPL)
- True-differential measurement architecture (vs ICL7106CPLZ)
- Direct drive for non-multiplexed LCDs (vs ICL7107CPL)
Notas de projeto
Route the true-differential input and reference as a compact, matched pair, and keep them away from the LCD segment and digit-drive traces. The converter contains high-impedance measurement and reference paths, while display outputs carry switched capacitive loads. Preserving spatial separation reduces coupling from display activity into the measured value. Place the input and reference components close to the relevant device pins and provide a quiet ground-return path according to the manufacturer's layout example.
Use the manufacturer's supply, decoupling, and grounding recommendations exactly because this DIP device combines sensitive analog conversion with relatively high-current LCD drive. Place the principal bypass capacitor close to the supply pins and keep display-current returns from sharing the same narrow path as the analog reference. Check capacitor voltage rating, polarity, temperature coefficient, and effective capacitance at the operating frequency. A stable supply is especially important when the reference establishes the conversion ratio.
Do not assume that every ICL7106 ordering code is interchangeable merely because the packages match. Validate suffix-specific temperature grade, marking, lifecycle status, supply limits, and timing against the manufacturer ordering information. Also verify that the chosen LCD is non-multiplexed and has the expected segment and polarity arrangement. The ICL7107CPL family is not a direct substitute when the PCB requires LCD drive rather than the corresponding LED-display outputs.
Treat the analog input and reference as high-impedance measurement nodes, and avoid long parallel copper runs next to LCD outputs. Connect sensor excitation and reference paths so common-mode variation is rejected by the differential input. If measuring a slow bridge or resistive sensor, keep connector and wiring leakage small relative to the intended source impedance. Validate settling and noise at the actual source impedance rather than relying only on the converter's headline resolution.
Informações de conformidade
The Analog Devices product page identifies the ICL7106 family as production. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals statements were not identified for this exact ordering code.