ICL7135CPIZ - 4.5-Digit BCD ADC | Renesas Electronics
MPN: ICL7135CPIZ ✓ 啟用中ICL7135CPIZ 概覽
A dual-slope integrating ADC is a mixed-signal data-conversion device that averages an input over controlled integration periods to suppress constant noise and reject unwanted frequencies. Within the broader hierarchy of analog-to-digital converters, data converters, and semiconductor signal-chain devices, the ICL7135 family is intended for digital-panel meters, digital voltmeters, laboratory instruments, weighing systems, and other equipment that must present a stable decimal result while also driving a multidigit display.
The ICL7135CPIZ includes four digit-drive outputs for multiplexed display operation and multiplexed BCD outputs for external decoding or digital processing. Its dual-slope conversion method is suited to slowly changing measurements because it offers good noise rejection without the complexity and switching noise of a high-frequency successive-approximation converter. The 4.5-digit architecture permits a negative 1-digit range for zero and overload indication in many panel-meter implementations.
The converter's differential input arrangement supports source impedance balancing and rejection of common-mode signals when the analog front end is designed correctly. With a 2.0000 V full-scale range, the 4.5-digit resolution corresponds to approximately 100 microvolts per count. This relationship makes the device suitable for precision measurement of voltage, resistance derived through a reference divider, temperature through a linearized sensor network, and other slowly varying quantities.
Typical uses include laboratory digital voltmeters, industrial panel meters, laboratory balances, process-monitoring instruments, and test equipment with decimal LED or LCD readouts. The integrated digit drivers simplify displays containing multiple digits, while the BCD interface allows the measurement result to be captured by a controller when an instrument also requires remote monitoring or data logging.
PCB design should preserve the high-impedance analog input path, provide a clean reference connection, and route display-driver and converter outputs away from sensitive input and reference nodes. Component tolerances, reference stability, input leakage, and grounding determine whether the converter's nominal resolution is realized in the finished instrument. The manufacturer datasheet should be used to assign every physical pin and implement the recommended input, reference, and bypass networks.
This page combines the converter's core architecture, package and interface characteristics, engineering guidance, comparison points, and practical application context. It is intended to support design selection and board planning rather than replace the manufacturer datasheet, reference schematic, or final qualification testing.
直接替換替代品,適用於 ICL7135CPIZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ICL7135CPIZ (相同外形與佔位) — 差異在於 Output Format, Conversion Accuracy, Converter Type, Input Architecture, Package.
ICL7135CPI+
✅ 直接替換聯絡詢價
查看資料表 →MAX1497EPI+
✅ 直接替換📋 參考替代品(不在目錄中)
ICL7135CPIZ 最大額定值與電氣特性
| Converter Type | Dual-slope integrating ADC |
| 解析度 | 4.5 digits |
| Output Format | Multiplexed BCD |
| Accuracy | ±1 count in 20,000 |
| Full-Scale Voltage | 2.0000 V |
| Nominal Resolution | 100 uV per count |
| Input Architecture | High-impedance differential input |
| Conversion Rate | Approximately 2 samples per second |
| Display Driver Outputs | 4 digit-drive outputs |
| BCD Output Signals | Multiplexed B1, B2, B4, and B8 outputs |
| Package Type | 28-pin PDIP |
| 腳位數 | 28 pins |
| 安裝方式 | Through-hole |
| Product Type | Display-driver precision ADC |
ICL7135CPIZ 28-pin pdip 腳位配置指南
ICL7135CPIZ(28-pin pdip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ICL7135CPIZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICL7135CPIZ 適用於 6 應用s: Digital Voltmeter, Industrial Panel Meter, Laboratory Measurement Instrument, Laboratory Balance Display, Process Monitoring Display, Temperature Measurement Panel.
Digital Voltmeter
The ICL7135CPIZ fits a digital voltmeter because its 4.5-digit dual-slope architecture provides ±1 count in 20,000 accuracy across a 2.0000 V full-scale range, equivalent to approximately 100 microvolts per count. The converter operates at about 2 samples per second, which favors a stable display over rapid sampling. Its four digit-drive outputs can operate a multiplexed numeric display, while the BCD outputs provide a path to remote data capture. A precision reference and balanced high-impedance differential input network remain essential for accurate results.
推薦
Industrial Panel Meter
For an industrial panel meter, the ICL7135CPIZ combines a 4.5-digit measurement format with integrated drivers for a multidigit display, reducing the need for separate display-driver circuitry. Its approximately 2 samples per second conversion rate is appropriate for temperature, pressure, load-cell, and process signals that change gradually. The ±1 count in 20,000 accuracy specification supports readable panel resolution, while the 2.0000 V full-scale range can be scaled by a precision input divider or front-end network.
推薦
Laboratory Measurement Instrument
The ICL7135CPIZ is appropriate for laboratory instruments that emphasize stable decimal readings, low update rates, and direct display interfacing. Its dual-slope conversion method integrates the input over controlled periods, which helps reject periodic interference in measurement environments. A 4.5-digit result, 100-microvolt nominal count value, and ±1 count in 20,000 accuracy support precision laboratory voltage measurements. Designers should use low-leakage input components and a stable reference because those external factors can dominate the complete instrument's error budget.
推薦
Laboratory Balance Display
A laboratory balance can use the ICL7135CPIZ when weight is converted into a slowly changing analog voltage and displayed with four digits plus an overflow indication. The approximately 2 samples per second update rate is useful because most mechanical or electronic scales do not require continuous high-rate sampling. The 4.5-digit format and ±1 count in 20,000 stated accuracy provide a suitable display framework. Reference stability, input leakage, excitation layout, and grounding should be controlled separately to preserve the useful resolution of the converter.
推薦
Process Monitoring Display
For process monitoring, the ICL7135CPIZ can acquire a slowly varying process voltage and present it directly through its multiplexed display outputs. The dual-slope architecture is well matched to signals affected by periodic noise because the integration process rejects unwanted periodic components. With a 2.0000 V full-scale range and approximately 2 samples per second, the device suits panel displays rather than waveform analysis. A protected input network should isolate field wiring from the converter's high-impedance measurement inputs.
推薦
Temperature Measurement Panel
The ICL7135CPIZ can form the measurement core of a temperature display when a linearized sensor or resistive bridge produces a voltage within the usable input range. Its 4.5-digit readout structure is useful for showing fractional temperature values, while the approximately 2 samples per second conversion rate provides continuously refreshed readings without excessive conversion activity. The dual-slope method helps suppress periodic interference. Sensor excitation, reference stability, and differential-input balance determine whether the displayed resolution reflects actual temperature accuracy.
推薦
推薦產品摘要
工程參考資料,適用於 ICL7135CPIZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ICL7135CPI | MAX1497EPI+ |
|---|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics | Analog Devices |
| Package | 28-pin PDIP | 28-pin PDIP | 28-pin PDIP |
主要差異化特點
- Integrated display-driver outputs (對比MAX1497EPI+)
- Defined precision and resolution (對比MAX1497EPI+)
- Directly integrated decimal-display interface (對比MAX1497EPI+)
- Same-family Renesas sourcing path (對比MAX1497EPI+)
設計說明
Keep the high-impedance input and reference nets short, clean, and away from the digit-drive outputs. Use a guarded or properly shielded analog input arrangement when nearby switching nodes or display lines could couple into the measurement channel. The input network should also preserve differential balance. Small, high-leakage-rejection components near the converter are generally preferable to long unprotected traces or breadboard-style interconnections in a precision measurement design.
Do not treat nominal 4.5-digit resolution as complete instrument accuracy. Reference drift, resistor tolerance, input offset, leakage, source impedance, and grounding can reduce real-world accuracy even when the converter meets its stated ±1 count in 20,000 specification. Start from the manufacturer's reference circuit, calculate the uncertainty of every external component, and test across temperature before claiming the displayed least-significant digit is meaningful.
Follow the manufacturer-recommended bypass and decoupling arrangement directly at the supply and reference pins. Separate sensitive reference routing from display-driver return currents, and provide adequate return paths so display transitions do not modulate the measurement reference. Check supply limits and sequencing requirements against the exact ICL7135CPIZ grade before connecting the 28-pin PDIP device to the board.
合規資訊
Material-compliance declarations and automotive qualification were not established for the exact ordering code. AEC-Q100 is treated as not applicable because the product is a general-purpose precision ADC rather than an explicitly automotive-qualified device.