ICS613MT - 157.5MHz Low-Phase-Noise Clock Multiplier | Renesas
MPN: ICS613MT ✗ 停產ICS613MT 概覽
A clock multiplier is a type of clock and timing integrated circuit that multiplies an input frequency while preserving the required phase relationship between input and output. Clock multipliers and frequency synthesizers form part of the wider clock generation, timing control, and power management hierarchy used to distribute precise timing signals among processors, communication links, converters, and data-conversion systems.
The ICS613MT combines a PLL-based architecture with a maximum frequency of 157.5MHz. Its input section supports either a clock or crystal source, while the single CMOS output stage provides a compatible interface for digital timing circuits. The 2:2 ratio provides a straightforward multiplication relationship, reducing the need to redesign the surrounding clock tree when a higher-frequency reference is required.
Phase noise and jitter are critical in high-speed digital systems because timing uncertainty limits usable bandwidth, increases communication error margins, and can degrade the effective resolution of converters. The ICS613MT is positioned as a low-cost, low-phase-noise clock synthesizer for applications requiring low phase noise and low jitter. Its single-clock architecture also helps simplify routing and reduces the number of independent timing branches that must be controlled on the PCB.
Typical uses include communications infrastructure, clocked data converters, digital signal processing modules, industrial control equipment, and embedded systems that require a deterministic local clock source. The device is also applicable when an existing low-frequency reference must be converted into a higher-frequency timing signal without relying on a more complex frequency synthesizer.
The primary design consideration is the relationship between the input source, crystal or clock requirements, and the intended output frequency. PCB layout should preserve a short and controlled path from the timing source to the input pins and from the device to the load. Power-supply decoupling, output fanout, and return-path continuity should be evaluated together because clock edges must remain clean at the receiver.
This product overview consolidates the ICS613MT clocking function, package information, key electrical characteristics, design guidance, sourcing information, and the limits of currently documented replacement options. Engineers should use the manufacturer datasheet for final pin assignments, recommended application circuits, operating limits, and timing parameters before releasing a production design.
直接替換替代品,適用於 ICS613MT — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此產品無可直接替換的替代品。
申請替代品ICS613MT 規格
| Product Type | Clock/Frequency Synthesizer |
| PLL | Yes |
| Input Type | Clock or crystal |
| 輸出類型 | CMOS |
| Maximum Frequency | 157.5MHz |
| Number of Circuits | 1 circuit |
| Input-to-Output Ratio | 2:2 |
| Package Type | 16-SOIC |
| Package Width | 3.90mm |
| Package Body Length | 0.154 inch |
| 安裝類型 | Surface mount |
| Clocking Function | Low-phase-noise clock multiplier |
| Phase Noise | Low phase noise |
| Jitter | Low jitter |
ICS613MT 0.154 inch 腳位配置指南
ICS613MT(0.154 inch 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: ICS613MT.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICS613MT 適用於 6 應用s: Communications Clock Distribution, ADC and DAC Sampling Clock, Digital Signal Processing Clock Tree, Industrial Control and Instrumentation, FPGA and Processor Timing, High-Speed Embedded Systems.
Communications Clock Distribution
The ICS613MT fits communication modules that need a local, multiplied clock with low phase noise and low jitter. Its PLL architecture accepts a clock or crystal reference, and the 2:2 nominal ratio provides a straightforward conversion to a higher-frequency timing signal. The CMOS output can feed a receiver, ADC, DAC, or FPGA clock input when the source impedance and load are compatible. Because timing jitter can affect link margin and conversion accuracy, the reference oscillator, supply decoupling, and output trace should be treated as one clock path. Use short routes, continuous ground planes, and termination matched to the receiving input rather than treating the clock as an ordinary low-frequency control signal.
推薦
ADC and DAC Sampling Clock
ICS613MT can provide a cleaner multiplied reference for mixed-signal systems that require deterministic sampling timing. The PLL-based clock synthesizer supports clock or crystal input, while the CMOS output and 157.5MHz maximum frequency cover applications operating below that limit. A low-jitter clock helps preserve the timing margin of successive-approximation, pipeline, and mixed-signal converters, provided the converter's aperture requirement is satisfied. The reference must remain stable over the converter’s acquisition interval, and the clock should be routed directly to the clock input with minimal stubs. Power and ground arrangements around the converter and multiplier should prevent switching activity from coupling into the reference or timing traces.
推薦
Digital Signal Processing Clock Tree
The ICS613MT is applicable to digital signal processing boards that require a predictable local clock derived from a lower-frequency source. Its 2:2 nominal ratio, low-phase-noise PLL architecture, and single CMOS output support clock-tree branches for DSPs, memory interfaces, and data converters. Low phase noise and low jitter are valuable when processing margins are limited or when timing errors accumulate across a chain of synchronous operations. The implementation should keep the reference and output paths away from high-current switching nodes, use a solid ground reference, and verify rise and fall behavior at the actual receiver. Crystal versus external-clock selection should follow the manufacturer reference design to maintain reliable startup and phase performance.
推薦
Industrial Control and Instrumentation
ICS613MT can support deterministic timing in industrial controllers, measurement instruments, and data-acquisition systems that synchronize sensors, converters, and digital processing blocks. A local PLL multiplier allows a stable reference to drive multiple timing functions without depending on a remote clock distribution network. The low-noise CMOS output is suitable for short, properly terminated routes to compatible digital inputs. Industrial equipment often places the timing circuit near switching regulators, relays, and high-energy analog stages, so layout quality remains essential. Separate the clock reference from noisy power paths, maintain continuous return current, and validate operation across the intended input frequency and load range. The 16-SOIC package also supports conventional surface-mount assembly.
推薦
FPGA and Processor Timing
The ICS613MT may be used to generate a multiplied clock for an FPGA, processor, programmable logic device, or high-speed interface in systems that accept a CMOS clock. Its PLL-based synthesis and low-jitter positioning help produce cleaner edges than an unbuffered divider or long passive clock network. The 157.5MHz maximum frequency makes the device relevant to clock trees operating at or below that limit, but the receiver’s minimum and maximum clock requirements must be checked. Route the output to the intended clock-capable pin, avoid accidental use as a general-purpose signal, and maintain a low-impedance ground reference. Power-supply bypass placement and output-load assumptions should be verified against the manufacturer application guidance.
推薦
High-Speed Embedded Systems
ICS613MT can provide a local timing signal for embedded systems that multiply a lower-frequency crystal or oscillator to drive internal logic, converters, or communication sections. Its single-circuit architecture reduces the number of separate clock-generation blocks when the required ratio is compatible with the 2:2 relationship. Low phase noise and low jitter benefit timing-critical control loops and serial interfaces, while the CMOS output simplifies connection to digital receivers. Designers should account for clock distribution loading, receiver thresholds, and the required startup behavior of the selected source. The device should be positioned near the timing load when trace length or crosstalk could affect edge quality, and sensitive reference routing should avoid proximity to motors, relays, power inductors, and high-di/dt nodes.
推薦
工程參考資料,適用於 ICS613MT — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 |
|---|---|
| Brand | Renesas Electronics |
| Package | 16-SOIC |
| Product Type | Clock/Frequency Synthesizer |
| PLL | Yes |
| Input Type | Clock or crystal |
| Output Type | CMOS |
| Maximum Frequency | 157.5MHz |
| Number of Circuits | 1 circuit |
| Input-to-Output Ratio | 2:2 |
| Phase Noise | Low phase noise |
| Jitter | Low jitter |
主要差異化特點
- Low-phase-noise clock multiplication (對比No verified drop-in alternative)
- Flexible reference selection (對比No verified drop-in alternative)
- Compact timing solution (對比No verified drop-in alternative)
設計說明
Place the ICS613MT close to the clock source and the intended clock receiver. Keep the reference and output traces short, avoid stubs, provide a continuous ground plane beneath the timing path, and keep the route away from switching-node copper and high-di/dt power traces. If the output drives a long trace or multiple loads, use a clock buffer or repeater rather than relying on the multiplier output to compensate for excessive loading.
Use the manufacturer application circuit as the basis for crystal or external-clock configuration. An external clock must meet the required amplitude, frequency, and edge characteristics, while a crystal installation must follow the specified load capacitance and layout. Keep support-component loops compact, use a low-impedance supply and ground connection, and measure the resulting edge at the receiver when timing margin is sensitive.
Do not treat a generic PLL with similar frequency capability as a drop-in substitute. A valid replacement must preserve the 16-SOIC pin functions, 2:2 nominal ratio, clock-or-crystal input behavior, CMOS output characteristics, and required timing performance. Verify the maximum operating frequency against the manufacturer’s complete operating table, and confirm startup behavior across the intended supply, temperature, reference, and load conditions before production release.
合規資訊
Lifecycle is listed as obsolete, and no verified compliance declarations or automotive qualification statement were identified.