INA322EA/2K5 - 25 V/V Micropower Instrumentation Amplifier | TI
MPN: INA322EA/2K5 ✓ 啟用中INA322EA/2K5 概覽
An instrumentation amplifier is a precision analog signal-conditioning component that amplifies the differential voltage between two inputs while rejecting common-mode interference. Its internal architecture is designed to provide high input impedance, consistent gain set by external resistors, and better common-mode rejection than ordinary op-amp configurations. The INA322 belongs to the broader hierarchy of instrumentation amplifier, analog amplifier, signal-conditioning IC, and power-management semiconductor.
The INA322EA/2K5 provides a 40 µA typical quiescent current, 25 V/V gain, 60 dB minimum common-mode rejection, and 10 pA typical input bias current. Its low bias current is particularly useful when measuring high-impedance sensors because it minimizes loading of the source. The 2 mV offset specification supports low-level differential measurements, while rail-to-rail output operation increases the usable output range within a compact single-supply system.
The gain is established with an external resistor, allowing the INA322 family to be used as a fixed-gain element in low-power analog front ends. Shutdown capability further reduces supply demand when measurements are not continuous. The manufacturer identifies the device as a low-cost, micropower CMOS instrumentation amplifier supporting single-supply and bipolar-supply operation, with the ordering code /2K5 denoting the 25 V/V configuration.
Typical uses include battery-powered sensor interfaces, portable measurement instruments, current-shunt monitoring, low-voltage process-control signals, and low-energy IoT nodes. Its small VSSOP package and low 40 µA supply current are advantageous when board area and battery life are primary constraints. For systems requiring very high precision or integrated analog-to-digital conversion, the INA322 can provide analog conditioning before a separate converter.
The main design consideration is input common-mode range: a differential signal is useful only while both input pins remain within the amplifier’s valid operating region. Input filtering, source impedance, resistor matching, and supply bypassing must therefore be evaluated together. Place the gain-setting resistor close to the appropriate device pin and connect the reference pin according to the manufacturer’s recommended application circuit when the output must be shifted.
This page combines the manufacturer’s device specifications with practical interface guidance, sourcing information, and a direct comparison against a pin-compatible INA326 alternative. It also highlights where the INA322’s 25 V/V gain, 40 µA operating current, and 8-pin VSSOP footprint simplify a micropower instrumentation design.
直接替換替代品,適用於 INA322EA/2K5 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
INA326EA/2K5G4
✅ 直接替換📋 參考替代品(不在目錄中)
INA322EA/2K5 最大額定值與電氣特性
| Device Type | Single-circuit instrumentation amplifier |
| Closed-Loop Gain | 25 V/V |
| 靜態電流 | 40 µA typical per channel |
| 關機電流 | 1 µA |
| Input Offset Voltage | 2 mV |
| Input Bias Current | 10 pA |
| Common-Mode Rejection Ratio | 60 dB minimum |
| Gain Temperature Coefficient | 2 ppm/°C |
| 輸出類型 | Rail-to-rail |
| 供應電壓 | 5 V |
| 工作溫度範圍 | -55 °C to 125 °C |
| 封裝 | 8-pin VSSOP (DGK) |
| Package Dimensions | 3.00 mm nominal width |
| Power-Supply Type | Single supply or bipolar supply |
| Process Technology | CMOS |
| 安裝類型 | Surface mount |
INA322EA/2K5 3.00 mm nominal width 腳位配置指南
INA322EA/2K5(3.00 mm nominal width 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA322EA/2K5.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA322EA/2K5 適用於 6 應用s: Battery-Powered Sensor Interface, Portable Industrial Measurement, Current-Shunt Monitoring, Low-Voltage Process Control, Smart IoT Sensing Node, Precision Bridge Signal Conditioning.
Battery-Powered Sensor Interface
The INA322EA/2K5 is appropriate for battery-powered sensor front ends because its 40 µA typical operating current limits amplifier demand while its 10 pA input bias current minimizes loading of high-impedance sources. Place the amplifier between the sensor and an ADC, set the 25 V/V gain with the manufacturer-recommended external resistor, and bypass the 5 V supply near the device. The rail-to-rail output can improve use of the available supply range. For low-level sensor signals, confirm that the common-mode input voltage remains inside the specified operating region and account for the 2 mV input offset when calculating end-to-end accuracy.
推薦
Portable Industrial Measurement
The INA322EA/2K5 supports compact handheld and portable test equipment where both board area and battery consumption are constrained. Its fixed 25 V/V gain provides predictable signal scaling without a complex programmable-gain architecture, while the 8-pin VSSOP package simplifies routing in a dense mixed-signal layout. A differential sensor or bridge output can feed the amplifier, followed by an ADC or display driver. Use the 60 dB minimum CMRR when assessing common-mode rejection, and verify source resistance because mismatched impedance can reduce practical rejection and disturb gain accuracy.
推薦
Current-Shunt Monitoring
The INA322EA/2K5 can condition the differential voltage generated by a low-value current-shunt resistor when the required gain and common-mode range align with the 25 V/V configuration. Its low 10 pA bias current produces less unwanted interaction with the shunt and measurement network than a higher-bias amplifier. Keep the two shunt connections as a short, symmetric pair and place filtering close to the input pins. Because the INA322 uses external gain-setting components, confirm resistor values and gain accuracy against the manufacturer gain-setting equations before production release.
推薦
Low-Voltage Process Control
The INA322EA/2K5 is suitable for conditioning low-level process-control signals in compact industrial modules that operate from a 5 V supply. The 25 V/V gain increases small differential sensor outputs before conversion, while the 40 µA typical current supports power-constrained remote nodes. The rail-to-rail output allows more of the supply range to be used, although the input common-mode limits still constrain the usable measurement window. For plant equipment, evaluate transient protection separately, keep high-current switching paths away from the input pair, and use a stable low-noise reference arrangement at the REF pin.
推薦
Smart IoT Sensing Node
The INA322EA/2K5 fits energy-conscious IoT sensing nodes that measure small differential signals while operating from a single low-energy rail. Its 40 µA typical consumption and 1 µA shutdown state allow the amplifier to remain active only during selected measurement intervals. The 10 pA bias current is useful with humidity, pressure, or chemical sensors that have relatively high output impedance. A duty-cycled acquisition sequence can use the shutdown function, but the sensor, ADC, and digital circuitry must also enter low-power states to obtain meaningful battery-life improvement.
推薦
Precision Bridge Signal Conditioning
The INA322EA/2K5 can serve as the analog gain stage for a bridge or other small differential sensor when the common-mode voltage and output swing are compatible with the device. The 25 V/V gain scales the bridge difference, while the 60 dB minimum CMRR helps reject supply and ground disturbances shared by both inputs. Use matched routing for the two input nets and place any input protection or filtering symmetrically to avoid gain imbalance. The 2 mV input offset contributes directly to measurement error, so include it in the uncertainty budget for low-range bridge measurements.
推薦
推薦產品摘要
工程參考資料,適用於 INA322EA/2K5 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA326EA/2K5G4 |
|---|---|---|
| Package | VSSOP-8 (DGK) | 8-pin MSOP-compatible package |
| Brand | Texas Instruments | Texas Instruments |
| Closed-Loop Gain | 25 V/V | 25 V/V |
| Output Swing | Rail-to-rail | Rail-to-rail |
主要差異化特點
- Low-power operation for portable measurement systems (對比INA326EA/2K5G4)
- Low input bias for high-impedance sources (對比INA326EA/2K5G4)
- Compact 25 V/V gain stage (對比INA326EA/2K5G4)
設計說明
Place the INA322EA/2K5 close to the source and ADC so the differential input pair has a short, symmetric route. Put the gain-setting resistor at the appropriate gain pin rather than extending the sensitive connection. Supply and ground bypass capacitors should also connect directly to the associated device pins, with the ground return arranged to minimize shared impedance with the input source. This layout reduces susceptibility to noise pickup and common-mode conversion caused by unequal trace resistance.
Do not assume that a differential signal is usable merely because the INA322 output can operate rail-to-rail. Both input voltages must remain within the specified common-mode range, and the output must remain within its linear swing limits after applying the 25 V/V gain. Check worst-case sensor output, resistor tolerance, supply tolerance, temperature drift, and the 2 mV input offset. A convenient bench calculation is Vout = 25 × Vid, followed by an overload check against the available output range.
Estimated: the amplifier’s specified 40 µA operating current multiplied by a 5 V supply corresponds to 200 µA of supply power, excluding external resistor and downstream loads. For a battery-powered design, include the 1 µA shutdown state, sensor standby current, ADC activity, pull networks, and regulator quiescent current in the complete energy budget. The estimate uses 5 V and 40 µA and should be replaced with worst-case design values for the actual supply and operating mode.
Use symmetric input filtering when differential EMI or broadband interference is present. Matching the series resistance and capacitor values in both input paths helps preserve CMRR and gain balance, particularly at higher frequencies. Avoid placing a large asymmetric protection network on one input. If the sensor is high impedance, account for leakage current through input protection devices and verify that the resulting bias error remains acceptable relative to the smallest signal being measured.
合規資訊