INA331IDGKT - Low-Power 8-Pin Instrumentation Amplifier | TI
MPN: INA331IDGKT ✓ 啟用中INA331IDGKT 概覽
An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal three-op-amp architecture provides high input impedance and accurate differential gain, while the INA331 simplifies the external signal chain by accepting single-supply or bipolar-supply operation. This places it within the hierarchy of instrumentation amplifier, differential amplifier, analog signal-conditioning IC, and power-management-independent semiconductor category.
The INA331 supports externally set gains from 1 V/V through 1000 V/V, with a specified 25 V/V configuration providing 0.02% gain accuracy and a 2 ppm/°C gain-temperature coefficient. Its 94 dB DC CMRR, 50 dB CMRR at 45 kHz, and 5 V/µs slew rate make it suitable for sensors, current measurement, and precision bridge interfaces. A shutdown mode reduces quiescent current to 0.01 µA.
Internally, the INA331 uses CMOS analog circuitry arranged to preserve low offset, low bias current, and accurate gain-setting behavior. The gain is established with an external resistor, which lets the designer select the required sensitivity without changing the package or PCB footprint. The 2.0 MHz bandwidth supports higher-speed signal bandwidth than many low-power precision instrumentation amplifiers, while the 5 V/µs slew rate helps maintain output linearity for rapidly varying inputs.
Typical uses include bridge and strain-gauge conditioning, battery and power-supply current monitoring, medical instrumentation, industrial process measurement, and low-level sensor amplification. Its rail-to-rail output allows useful signal range in low-voltage systems, and its low 415 µA supply current supports portable and battery-operated equipment.
For stable operation, place the gain-setting resistor close to the device, maintain the specified supply and common-mode voltage limits, and provide adequate input and output decoupling. Check the shutdown logic, output-reference arrangement, and input bias-current requirements against the sensor source impedance before finalizing the circuit.
This page combines device specifications, replacement guidance, application-oriented engineering notes, and parameter comparisons to support component selection and PCB design. It is intended to help engineers evaluate the INA331IDGKT for low-noise, low-power differential measurement without relying on raw catalog listings alone.
直接替換替代品,適用於 INA331IDGKT — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA331IDGKT (相同外形與佔位) — 差異在於 Bandwidth, Number of Channels, Operating Temperature Range, Quiescent Current, Slew Rate.
INA331AIDGKR
✅ 直接替換📋 參考替代品(不在目錄中)
INA332AIDGKR
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
INA320AIDGKR
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
INA333AIDGKR
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →INA337AIDGKR
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
INA331IDGKT 最大額定值與電氣特性
| Amplifier Type | Low-power, single-supply CMOS instrumentation amplifier |
| Number of Channels | 1 circuit |
| Supply Configuration | Single supply or bipolar supply |
| Output Swing | Rail-to-rail |
| 靜態電流 | 415 µA |
| Shutdown Quiescent Current | 0.01 µA |
| Gain | 25 V/V |
| Gain Accuracy | 0.02% |
| Gain Temperature Coefficient | 2 ppm/°C |
| Offset Voltage | ±250 µV |
| CMRR at DC | 94 dB |
| CMRR at 45 kHz | 50 dB |
| Bandwidth | 2.0 MHz |
| Slew Rate | 5 V/µs |
| Bias Current | 0.5 pA |
| 工作溫度範圍 | -55 °C to +125 °C |
| 封裝 | 8-pin VSSOP (DGK) |
| 安裝類型 | Surface mount |
INA331IDGKT 8-pin vssop (dgk) 腳位配置指南
INA331IDGKT(8-pin vssop (dgk) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA331IDGKT.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA331IDGKT 適用於 6 應用s: Battery-Powered Sensor Conditioning, Strain-Gauge Bridge Measurement, Power-Supply Current Monitoring, Medical Signal Measurement, Industrial Process Control, Portable Instrument Signal Chain.
Battery-Powered Sensor Conditioning
The INA331IDGKT fits battery-powered sensor interfaces because it combines a 415 µA normal quiescent current with a 0.01 µA shutdown current. Its low 415 µA operating draw reduces the continuous load imposed by the measurement amplifier without requiring a high-speed signal path. The 2.0 MHz bandwidth and 5 V/µs slew rate can handle sensor outputs that vary during measurement, while the 8-pin VSSOP package supports compact layouts. Place the gain-setting resistor close to the device and use shutdown to remove supply consumption during inactive intervals. Confirm that sensor leakage, source impedance, and the required duty cycle remain compatible with the input bias and supply specifications.
推薦
Strain-Gauge Bridge Measurement
The INA331IDGKT is appropriate for strain-gauge and resistive-bridge excitation because the INA331 family combines low offset of ±250 µV, 94 dB DC CMRR, and externally adjustable gain. These characteristics help preserve a small differential bridge output while rejecting the larger common-mode voltage present at the inputs. Its 25 V/V example gain supports moderate-signal designs without requiring a high-gain amplifier, and the 2.0 MHz bandwidth is suitable for dynamic measurements. Use a stable excitation source, route the bridge and amplifier grounds carefully, and keep the gain resistor close to the corresponding device pin to limit parasitic effects.
推薦
Power-Supply Current Monitoring
The INA331IDGKT can amplify the differential output of a current-sense element in power-conversion and battery-management systems. Its rail-to-rail output increases usable signal swing in low-voltage rails, while the 5 V/µs slew rate allows the output to follow current changes encountered in load transients. A gain of 25 V/V provides a practical starting point when the sense voltage is small, and the 415 µA quiescent current limits the burden on auxiliary supply rails. The external gain resistor and output-reference connection determine the scaling and zero level, so both must be calculated against the system’s current range.
推薦
Medical Signal Measurement
The INA331IDGKT can serve as the analog input stage for low-level biomedical or diagnostic instrumentation when the signal source is differential and operates within the device’s common-mode range. Its ±250 µV offset, 94 dB DC CMRR, and externally selected gain support accurate amplification of small physiological or diagnostic signals. The low-power operation is useful in portable instruments, and rail-to-rail output helps use low-voltage analog rails efficiently. Protection, isolation, patient-leakage requirements, and electrode-specific filtering must be evaluated separately; those safety functions are not inherently provided by the instrumentation amplifier itself.
推薦
Industrial Process Control
The INA331IDGKT is useful in industrial process-measurement front ends that amplify differential outputs from pressure, temperature, and current transducers. Its 94 dB DC CMRR helps reject plant noise on long sensor lines, and the 2.0 MHz bandwidth is more than adequate for many slowly varying process signals while preserving response to faster events. The low 415 µA supply current also supports distributed instrumentation. Input protection, surge handling, grounding, and calibration should be designed around the transducer and installation environment. Use the manufacturer reference circuits and pin descriptions when establishing the reference, gain, and supply connections.
推薦
Portable Instrument Signal Chain
The INA331IDGKT supports portable test and measurement equipment that must combine low power with useful small-signal bandwidth. Its 415 µA quiescent current reduces continuous supply demand, and the rail-to-rail output provides greater headroom than a fixed-output amplifier. The 5 V/µs slew rate and 2.0 MHz bandwidth allow the device to serve as an input stage for transducers rather than only very slow precision measurements. Designers can set the required differential gain with an external resistor and then feed a suitable ADC. Thermal performance and analog-noise performance should be checked over the complete measurement bandwidth and operating-temperature range.
推薦
推薦產品摘要
工程參考資料,適用於 INA331IDGKT — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA331AIDGKR | INA332AIDGKR | INA320AIDGKR | INA333AIDGKR | INA337AIDGKR |
|---|---|---|---|---|---|---|
| Package | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Amplifier Type | Low-power, single-supply CMOS instrumentation amplifier | INA331-family instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier |
主要差異化特點
- Low-power operation with useful signal bandwidth (對比INA333AIDGKR)
- Fast output slew rate for dynamic differential signals (對比INA320AIDGKR)
- Rail-to-rail output improves low-voltage signal range (對比INA332AIDGKR)
設計說明
Place the external gain-setting resistor close to the corresponding INA331 gain pin and keep the differential input traces short and symmetrical. Route the differential pair away from switching nodes and high-current paths to minimize conversion of common-mode switching noise into differential error. Use a continuous ground plane beneath the device, but avoid placing disruptive return currents directly under the analog input or reference nodes.
Decouple the supply pins with capacitors selected according to the manufacturer reference circuit and placed as close as practical to the device. Keep the shutdown control away from noisy digital routes and define its inactive state so the input amplifier does not consume unnecessary power between measurements. Confirm that the selected supply voltage remains inside the INA331 operating range under startup, load, and supply-transient conditions.
Treat the sensor source impedance as part of the input network. Very high source impedances can increase error currents at the inputs, while long unbalanced cables can degrade common-mode rejection before the signal reaches the amplifier. For bridge and transducer circuits, use shielded or differential routing, minimize connector transitions, and verify the complete signal chain with the configured gain resistor rather than relying only on the 2.0 MHz small-signal bandwidth figure.
Do not assume that two 8-pin VSSOP instrumentation amplifiers are automatically interchangeable. Before replacing INA331IDGKT, compare pin assignments, common-mode range, output-reference behavior, gain equation, shutdown logic, supply limits, offset, bandwidth, and noise. In particular, verify that the external gain resistor value remains correct for the selected alternative and that its output can meet the required signal swing.
合規資訊
RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status were not stated in the manufacturer or catalog information reviewed. The device is described as an active Texas Instruments INA331-family orderable part in an 8-pin VSSOP package.