MAX232ECWE+TG104 - Dual RS-232 IC | Analog Devices
MPN: MAX232ECWE+TG104 ✓ 啟用中MAX232ECWE+TG104 概覽
An RS-232 transceiver is an interface integrated circuit that converts logic-level signals into RS-232-compatible levels and converts received RS-232 signals back into logic levels. It belongs to the line-driver and line-receiver hierarchy within interface ICs. This device is intended for bidirectional serial communication over cables or other RS-232 links where the host supplies a single positive supply voltage.
The principal features of the MAX232ECWE+TG104 are its dual 2/2 transceiver arrangement, 4.5 V to 5.5 V supply range, integrated charge-pump capability, and integrated ±15 kV human-body-model ESD protection. The 16-pin gull-wing SOIC package supports conventional surface-mount assembly and provides enough pins for the receiver, transmitter, supply, ground, and externally connected charge-pump capacitors.
The MAX232 family uses CMOS-compatible logic on the digital interface side while the integrated charge-pump circuitry creates the bipolar voltage levels required by RS-232. This arrangement simplifies system power design because the circuit does not require separate positive and negative supplies. ESD protection integrated into the interface can improve resistance to electrostatic discharge encountered during handling or connection of external cabling.
Typical uses include industrial control equipment, data-acquisition systems, serial adapters, service-console interfaces, and legacy peripheral connections. In each case, the transmitter converts outgoing logic signals into RS-232 levels, while the receiver translates incoming levels into logic signals understood by the host controller. The commercial temperature grade identifies this ordering code as intended for normal commercial operating conditions.
Designers should place the required external capacitors close to the charge-pump pins and route the RS-232 interface traces away from sensitive digital signals. Ground-return continuity and compliant cable practices remain important because integrated ESD protection does not eliminate the need for good enclosure and grounding practices. Confirm the complete pin assignment, absolute maximum ratings, and capacitor values against the manufacturer datasheet before layout release.
This product page combines the device identification, verified technical characteristics, sourcing guidance, and application-focused design information. It also identifies genuinely comparable package and ordering variants while making clear where a complete pin-level alternative cannot be established without additional manufacturer cross-reference information.
直接替換替代品,適用於 MAX232ECWE+TG104 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MAX232ECWE+TG104 (相同外形與佔位) — 差異在於 Product Type, Interface Standard, Package, Supply Voltage Range, ESD Protection.
MAX232EWE+
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →MAX232CWE+
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →MAX232ESE+
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →MAX232ECWE+TG104 規格
| Product Type | RS-232 transceiver |
| Transmitter Count | 1 transmitter |
| Receiver Count | 1 receiver |
| Transceiver Configuration | 2/2 dual RS-232 transceiver |
| Supply Voltage Range | 4.5 V to 5.5 V |
| ESD Protection | ±15 kV HBM |
| Charge-Pump Circuitry | Integrated |
| External Bipolar Supply | Not required |
| 封裝 | 16-pin SOIC |
| Terminal Count | 16 terminals |
| Terminal Form | Gull wing |
| Package Code | SOP |
| Package Shape | Rectangular |
| Temperature Grade | Commercial |
| 安裝類型 | Surface mount |
| Logic Interface | CMOS-compatible logic |
MAX232ECWE+TG104 rectangular 腳位配置指南
MAX232ECWE+TG104(rectangular 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX232ECWE+TG104.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX232ECWE+TG104 適用於 6 應用s: Industrial Control Console Interface, Data Acquisition Equipment, Serial Service Adapter, Legacy Peripheral Connectivity, Point-of-Sale Terminal, Instrumentation Communication Port.
Industrial Control Console Interface
The MAX232ECWE+TG104 fits an industrial controller that must communicate with a legacy RS-232 console using only a 5 V power rail. Its 4.5 V to 5.5 V operating range and integrated charge-pump circuitry eliminate the need for a separate bipolar supply, reducing supply-tree complexity. The 16-pin SOIC package is suitable for conventional surface-mount assembly, while ±15 kV HBM ESD protection adds interface ruggedness where a service cable may be connected. In implementation, the transmitter accepts host-side logic and produces RS-232 levels, while the receiver converts the returning signal. Place the required external capacitors near their associated pins and maintain a continuous signal-ground path with the connected equipment.
推薦
Data Acquisition Equipment
The MAX232ECWE+TG104 is suitable for linking a data-acquisition instrument to a host computer through an RS-232 port. The single 4.5 V to 5.5 V supply range simplifies instrumentation power distribution, while the integrated charge pump generates the bipolar signal levels required by RS-232 without an external negative rail. Its 2/2 transceiver arrangement supports one outbound data path and one inbound data path, making it appropriate for command and measurement traffic. The ±15 kV HBM ESD rating provides useful robustness for laboratory and industrial cabling, although correct grounding remains essential. Follow the manufacturer typical-application diagram for capacitor placement, and verify logic levels and timing in the host interface circuit.
推薦
Serial Service Adapter
The MAX232ECWE+TG104 can provide the electrical interface in a compact serial service adapter connected to a controller board. Because the device operates from 4.5 V to 5.5 V and includes a charge pump, an adapter can be powered from a conventional positive rail instead of requiring a bipolar supply. The 16-pin SOIC package also supports dense surface-mount layouts. Integrated ±15 kV HBM protection is particularly relevant when the adapter handles an exposed service connector. Designers should still include overcurrent protection and grounding appropriate to the product enclosure, verify the connector's signal assignments, and route transceiver traces away from switching nodes and sensitive analog circuitry to minimize coupling.
推薦
Legacy Peripheral Connectivity
The MAX232ECWE+TG104 allows a modern controller to communicate with equipment that exposes only an RS-232 connector. Its 2/2 transceiver configuration handles one direction for transmitting commands and the other for receiving responses, while the 4.5 V to 5.5 V supply range aligns with common embedded power systems. Integrated charge-pump circuitry reduces the external power-supply burden, and ±15 kV HBM ESD protection improves robustness at the cable interface. Before layout release, confirm that the legacy device uses compatible logic levels and that the RS-232 ground is connected. Keep the interface connector and protection network away from high-current paths, and use the manufacturer pin table to confirm every net.
推薦
Point-of-Sale Terminal
The MAX232ECWE+TG104 is applicable to point-of-sale equipment that communicates with a peripheral through a wired RS-232 link. The single-supply 4.5 V to 5.5 V operation allows the interface to share a common positive rail in compact terminal electronics, and the integrated charge pump avoids a separate negative-voltage generator. Its 2/2 arrangement supports command transmission and status reception, while ±15 kV HBM ESD protection helps protect the interface from electrostatic discharge encountered during installation or servicing. The 16-pin gull-wing SOIC is compatible with standard surface-mount production methods. Maintain short return paths between logic and connector grounds, and validate the peripheral's voltage levels and handshake signals before releasing the design.
推薦
Instrumentation Communication Port
The MAX232ECWE+TG104 is well suited to instrumentation that must report measurements and accept configuration commands through RS-232. Its 4.5 V to 5.5 V supply range supports standard 5 V instrumentation architectures, while integrated charge-pump circuitry removes the need for external positive and negative rail generation. The device provides one transmitter and one receiver for bidirectional control and data traffic, and its ±15 kV HBM protection is useful in bench and field environments. Use the manufacturer recommended capacitor values and place them close to the charge-pump network. Also keep the RS-232 return connected, provide suitable connector protection, and separate the interface routing from high-noise switching stages to preserve signal integrity.
推薦
推薦產品摘要
工程參考資料,適用於 MAX232ECWE+TG104 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX232EWE+ | MAX232CWE+ | MAX232ESE+ |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | SOIC-16 | SOIC-16 | SOIC-16 | SOIC-16 |
| Transceiver Configuration | 2/2 dual RS-232 transceiver | 2/2 dual RS-232 transceiver | 2/2 dual RS-232 transceiver | 2/2 dual RS-232 transceiver |
| Supply Voltage Range | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V |
| Charge-Pump Circuitry | Integrated | Integrated | Integrated | Integrated |
| External Bipolar Supply | Not required | Not required | Not required | Not required |
| Ordering Suffix | TG104 shipment code | No TG104 shipment code | No TG104 shipment code | No TG104 shipment code |
| Mounting Type | Surface mount | Surface mount | Surface mount | Surface mount |
主要差異化特點
- Exact TG104 ordering configuration (對比MAX232EWE+)
- Single 5 V supply operation with integrated charge pump (對比MAX232CWE+)
- Integrated high-level ESD protection (對比MAX232ESE+)
設計說明
Place the external charge-pump capacitors close to the corresponding MAX232ECWE+TG104 pins and use the shortest practical ground return permitted by the manufacturer layout. Keep the RS-232-side connector and interface traces away from switching-regulator nodes, clock lines, and sensitive analog inputs. A compact placement reduces parasitic distortion, while maintaining separation prevents charger-pump and switching energy from coupling into the communication path.
Do not substitute a MAX232 ordering code solely because the device family name and package appear similar. The TG104 shipment suffix, temperature grade, ESD rating, lead-free status, and reel configuration must be checked against the production bill of materials. MAX232CWE+ may not provide the same temperature qualification as the E-series ordering code, and the manufacturer documentation should be used to confirm the final assembled part.
Route the transceiver and connector side of the circuit as an interface zone separated from power-conversion and processor circuitry. Provide a direct, continuous ground connection between the logic ground and the RS-232 connector reference when the linked equipment permits it. Avoid long shared paths that carry unrelated return current, because such routing can degrade signal integrity and make ESD events less effectively shunted.
The integrated charge pump eliminates an external bipolar supply, but its switching energy can still couple into nearby circuitry. Follow the manufacturer typical-application layout, minimize loop area around the charge-pump network, and maintain solid ground-plane continuity. If the surrounding system contains sensitive analog or high-speed digital nodes, add filtering and separation according to the system signal-integrity requirements rather than relying only on the IC's internal ESD protection.
合規資訊
The product information identifies a commercial-grade RS-232 interface IC but does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable to this general-purpose commercial interface IC.