MAX232EIDRG4 - Protected Dual RS-232 Transceiver | Texas Instruments
MPN: MAX232EIDRG4 ✓ 啟用中MAX232EIDRG4 概覽
An RS-232 transceiver is an interface IC that translates logic-level signals between a host or controller and a RS-232 link. Within the interface hierarchy, the MAX232EIDRG4 combines a line driver, receiver, charge-pump voltage supply, and electrostatic-discharge protection in one package. It is commonly placed between TTL or CMOS UART circuitry and an external DB9, terminal-block, or cable connection when an RS-232 port requires ± voltage signaling.
Key features include two drivers, two receivers, operation from one 5 V supply, and 1.0 µF charge-pump capacitors. The device operates to 120 kbit/s and accepts receiver input voltages of ±30 V. It meets or exceeds TIA/RS-232-F and ITU Recommendation V.28. These characteristics make it suitable for legacy industrial equipment, point-of-sale systems, test instruments, and computer peripherals using asynchronous RS-232 communication.
The MAX232 interface architecture uses internal charge pumps to generate the positive and negative voltages required by RS-232 drivers. Separate driver and receiver channels allow two simultaneous communication directions, while the E-series protection network reduces vulnerability to IEC 61000-4-2 discharge events on exposed lines. Because RS-232 is a single-ended, unbalanced interface, board layout, grounding, cable routing, and connector selection remain important to practical signal integrity.
Typical uses include configuration links between industrial controllers and service equipment, diagnostic ports on test and measurement systems, serial communication in POS terminals, and legacy computer or peripheral interfaces. In these applications, the device provides the voltage conversion needed by a UART while the system-side logic continues to use normal TTL or CMOS levels.
Place the required charge-pump capacitors close to their designated pins and route each protected RS-232 line directly toward its connector. Confirm line polarity, ground continuity, and the voltage rating of the connector before energizing the interface. Review the manufacturer datasheet for the exact external-capacitor values, input thresholds, and protection configuration before releasing a production design.
直接替換替代品,適用於 MAX232EIDRG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
MAX232IDRG4
✅ 直接替換聯絡詢價
查看資料表 →MAX232ECSE
✅ 直接替換📋 參考替代品(不在目錄中)
MAX232EIDRG4 規格
| Product Type | Dual RS-232 driver/receiver transceiver |
| Number of Drivers | 2 channels |
| Number of Receivers | 2 channels |
| 供應電壓 | 5 V |
| Maximum Data Rate | 120 kbit/s |
| Charge-Pump Capacitor Value | 1.0 µF |
| Receiver Input Voltage Range | -30 V to +30 V |
| 工作溫度範圍 | -40 °C to +85 °C |
| 封裝 | 16-pin SOIC |
| Electrostatic-Discharge Protection | IEC 61000-4-2 |
| RS-232 Compliance | TIA/RS-232-F |
| ITU Recommendation | V.28 |
| 安裝類型 | Surface mount |
MAX232EIDRG4 16-pin soic 腳位配置指南
MAX232EIDRG4(16-pin soic 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX232EIDRG4.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX232EIDRG4 適用於 6 應用s: Industrial Controller Service Port, Test and Measurement Equipment, Point-of-Sale Terminal, Computer Peripheral Interface, Embedded Data Acquisition Unit, Remote Monitoring and Control.
Industrial Controller Service Port
The MAX232EIDRG4 fits a service port that must bridge a 3.3 V or 5 V UART controller to an RS-232 connector. Its two driver and two receiver channels support bidirectional serial communication, while the 120 kbit/s capability is sufficient for command, diagnostic, and configuration traffic. The 5 V supply requirement simplifies use with common embedded rails, and 1.0 µF charge-pump capacitors support the on-chip voltage conversion. IEC 61000-4-2 protection is particularly relevant when the connector is accessible to maintenance personnel or connected to longer field cables. Confirm connector pinout and interface levels before deployment.
推薦
Test and Measurement Equipment
The MAX232EIDRG4 is appropriate for test instruments that expose an RS-232 configuration or trigger interface to operators and service technicians. The dual-channel arrangement allows two serial links or a full-duplex pair, and the 120 kbit/s rate supports instrument-control protocols, boot-loader traffic, and legacy data capture. Operation from a single 5 V rail and the -40 °C to +85 °C rating support laboratory and industrial test environments. The E-series ESD protection adds a useful layer at an exposed connector, although chassis grounding and external surge protection may still be required for long cables.
推薦
Point-of-Sale Terminal
A point-of-sale terminal can use the MAX232EIDRG4 to connect a UART-based controller, receipt printer, or customer-display peripheral through RS-232. The two transmitters and two receivers support a practical mix of communication ports, while the 120 kbit/s maximum accommodates legacy point-of-sale protocols. A single 5 V supply simplifies integration with terminal electronics, and the protected E-series configuration is useful when the connector is accessible in a retail environment. System designers should still route the RS-232 return ground correctly, use twisted-pair cabling, and verify whether the peripheral requires hardware flow control.
推薦
Computer Peripheral Interface
The MAX232EIDRG4 supports legacy computer peripherals that expose an RS-232 port for configuration, diagnostics, or low-speed data transfer. Its 2/2-channel organization permits two driver outputs and two receiver inputs, while operation to 120 kbit/s is suitable for many peripheral protocols and service commands. The 16-SOIC package simplifies assembly in compact industrial computers and embedded controllers. Where the port is user-accessible, the documented IEC 61000-4-2 protection is advantageous. Confirm whether the equipment expects RS-232 signal polarity, connector gender, or flow-control signals before laying out the board.
推薦
Embedded Data Acquisition Unit
The MAX232EIDRG4 can connect a data-acquisition controller or embedded logger to an RS-232 instrument, sensor, or service computer. Its 120 kbit/s maximum data rate is appropriate for command traffic, sampled status data, and legacy laboratory equipment. Two receiver and two driver channels allow a compact multi-port implementation without adding another transceiver package. The single 5 V supply and -40 °C to +85 °C range suit embedded equipment deployed in controlled industrial environments. ESD protection on exposed lines improves robustness, but designers should keep the ground reference continuous and consider galvanic isolation where large ground-potential differences are possible.
推薦
Remote Monitoring and Control
The MAX232EIDRG4 is useful in remote monitoring equipment that uses a wired RS-232 link for configuration, telemetry, or alarm reporting. Its protected E-series construction addresses IEC 61000-4-2 discharge exposure at accessible ports, while the dual transmitter and receiver arrangement can support separate command and status channels. The 5 V supply is compatible with many embedded power systems, and the 120 kbit/s rate exceeds typical supervisory-character rates. For installations spanning separate power systems, include isolation and robust grounding to avoid surge damage or communication errors that cannot be solved by the transceiver's internal ESD protection alone.
推薦
推薦產品摘要
工程參考資料,適用於 MAX232EIDRG4 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX232IDRG4 | MAX232ECSE |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-SOIC | 16-SOIC | 16-SOIC |
主要差異化特點
- Documented electrostatic-discharge protection (對比MAX232IDRG4)
- Single-supply RS-232 operation (對比MAX232IDRG4)
- Broad industrial temperature coverage (對比MAX232ECSE)
設計說明
Place the two 1.0 µF charge-pump capacitors close to their designated MAX232EIDRG4 pins, using the shortest possible connections and a solid ground return. Keep the RS-232 driver and receiver routes away from clocks, switching-regulator nodes, and sensitive analog inputs. Route each cable-side signal directly toward its connector, and provide a continuous ground reference between the transceiver and the RS-232 connector rather than relying on chassis ground alone.
Do not assume that the 120 kbit/s datasheet rating guarantees reliable communication over every cable length or baud rate. Confirm the UART oscillator tolerance, cable type, connector wiring, remote ground, and electromagnetic environment. Also verify the MAX232EIDRG4 data-direction assignments: an RS-232 driver output must connect to the remote receiver input, not to another driver output, because the interface is unbalanced and point-to-point.
Treat IEC 61000-4-2 protection as component-level ESD protection rather than a complete industrial surge solution. For long cables or an outdoor connector, add appropriate common-mode and surge protection, maintain protective-earth bonding, and use twisted-pair wiring. Keep the protected cable interface away from the 5 V supply entry point and high-current return paths to reduce differential noise and ground bounce.
Decouple the 5 V supply locally and verify the regulator's behavior during RS-232 driver transitions. The charge-pump network creates switching current internally, so a short supply loop and low-impedance ceramic bypass capacitor help prevent rail disturbance. Confirm the exact charge-pump capacitor tolerances and stability requirements in the manufacturer datasheet, and avoid adding long test pads or stubs to the protected interface lines.
合規資訊
RoHS and REACH compliance are stated for the MAX232EIDRG4. The available product information does not explicitly identify AEC-Q100 qualification, lead-free construction, halogen-free status, or conflict-minerals compliance.