MAX3387EEUG+T - 3V RS-232 Transceiver | Analog Devices
MPN: MAX3387EEUG+T ✓ 啟用中MAX3387EEUG+T 概覽
An RS-232 transceiver is a semiconductor interface that converts logic-level signals into RS-232 voltage levels and converts received RS-232 signals back into digital logic levels. The MAX3387E belongs to the interface IC hierarchy, where it bridges a host controller and external data-terminal equipment through EIA/TIA-232 links. Its dual charge-pump design supports true RS-232 operation from a low-voltage supply without a separate negative supply rail.
The device provides three driver channels and three receiver channels, allowing two RS-232 ports or several individual data paths to be implemented in one package. A proprietary low-dropout transmitter output stage enables operation from supplies up to 5.5V while maintaining compliant output levels. The manufacturer also identifies enhanced ESD protection, with the product listing specifying 15kV protection.
At data rates up to 250kbps, the MAX3387EEUG+T is appropriate for data links that require more throughput than a conventional low-speed serial port. Its internal charge pumps require four 0.1uF capacitors for operation from 3.3V. This compact approach eliminates the external negative-voltage supply circuitry commonly associated with older RS-232 implementations, reducing board area and simplifying system power design.
Typical applications include industrial control terminals, data-acquisition equipment, point-of-sale terminals, configuration interfaces, portable diagnostic equipment, and embedded serial adapters. Multiple driver and receiver channels also suit designs that combine console, firmware-update, and peripheral-control links while limiting the number of interface ICs on the board.
PCB design should keep the charge-pump capacitors close to their associated pins and provide adequate return paths for high-speed transitions. Designers should also distinguish powered logic-side signals from externally accessible RS-232 lines, route cables to reduce ESD exposure, and verify signal polarity and logic levels on every connected channel before production release.
This page combines the manufacturer interface description with verified ordering information, a focused drop-in cross-reference, and practical implementation guidance. It is intended to help engineers identify the correct package variant, compare compatible devices, and implement a compact, low-power RS-232 interface without overlooking supply, ESD, or signal-integrity constraints.
直接替換替代品,適用於 MAX3387EEUG+T — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MAX3387EEUG+T (相同外形與佔位) — 差異在於 Package, ESD Protection.
MAX3387ECUG+T
✅ 直接替換聯絡詢價
查看資料表 →MAX3387EEUG+T 規格
| Product Type | 3/3 RS-232 transceiver |
| Transmitter Channels | 3 channels |
| Receiver Channels | 3 channels |
| Supply Voltage Range | 3 V to 5.5 V |
| Maximum Data Rate | 250 kbps |
| ESD Protection | 15 kV |
| Charge Pump | Dual charge pump |
| Charge Pump Capacitors | 4 x 0.1 uF |
| Transmitter Output Stage | Proprietary low-dropout design |
| Communication Standard | EIA/TIA-232 and V.28/V.24 |
| 封裝 | 24-pin TSSOP |
| 安裝類型 | Surface mount |
MAX3387EEUG+T 24-pin tssop 腳位配置指南
MAX3387EEUG+T(24-pin tssop 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX3387EEUG+T.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX3387EEUG+T 適用於 6 應用s: Industrial Control Terminals, Data-Acquisition Equipment, Point-of-Sale Terminals, Portable Diagnostic Equipment, Embedded Configuration Interfaces, RS-232-to-Embedded Adapters.
Industrial Control Terminals
The MAX3387EEUG+T fits industrial control terminals that require multiple RS-232 links from a 3V or 3.3V system supply. Its three transmitters and three receivers can support separate console, status, and service paths without requiring three single-channel interface devices. Operation to 250kbps provides useful throughput for configuration traffic and diagnostic protocols, while the dual charge pump removes the need for an external negative supply. Designers should reserve the 15kV ESD capability as one layer of protection and verify the complete cable-entry protection scheme against the enclosure and installation environment.
Data-Acquisition Equipment
The MAX3387EEUG+T is appropriate for compact data-acquisition equipment that connects a controller to external measurement or laboratory peripherals through RS-232. The three transmitter and receiver channels allow a single package to serve bidirectional links that would otherwise consume several board areas. A 250kbps maximum rate supports legacy instrumentation protocols, and operation from 3V to 5.5V simplifies adaptation across industrial and embedded platforms. The four required 0.1uF charge-pump capacitors should be placed according to the manufacturer layout guidance, with cable routing and grounding checked to minimize noise and ESD exposure.
Point-of-Sale Terminals
Point-of-sale terminal designers can use the MAX3387EEUG+T for peripheral, printer, display, or service connections where RS-232 remains common in installed equipment. Three drivers and three receivers provide channel flexibility for multiple peripherals, while the low-voltage charge-pump architecture avoids a separate negative rail in compact systems. Its data-rate capability of up to 250kbps exceeds the needs of many legacy transaction peripherals and supports more demanding firmware or diagnostic channels. Board planning should account for all seven interface channels, proper logic-level translation where required, and protection at externally accessible connector pins.
Portable Diagnostic Equipment
The MAX3387EEUG+T suits portable diagnostic and service equipment that communicates with embedded controllers, adapters, or test fixtures. Its 3V minimum supply supports compact systems, and the internal dual charge pump generates RS-232 levels without an external negative power supply. Multiple channels can maintain separate communication paths for a device under test, a configuration interface, and an operator console. The 24-pin TSSOP package helps control board area, but thermal and grounding design remain important because connector transients and cable-induced noise can affect receiver margins. External protection should be evaluated for field-accessible ports.
Embedded Configuration Interfaces
The MAX3387EEUG+T can support embedded configuration, firmware-update, and production-test interfaces in systems that retain an RS-232 command port. A 3.3V host can operate the interface without a separate negative supply, and the 250kbps rate is suitable for common command protocols and service logs. The three-driver, three-receiver arrangement permits concurrent paths where the host must distinguish command, status, and auxiliary channels. Firmware designers should define idle levels and polarity explicitly, while hardware engineers should use the manufacturer’s pin table and charge-pump layout to prevent startup or signal-integrity issues.
RS-232-to-Embedded Adapters
The MAX3387EEUG+T is well suited to compact RS-232 interface adapters that bridge a modern embedded controller with legacy peripheral equipment. Three full-duplex channel pairs allow one adapter to consolidate printer, instrument, and service connections, while the 250kbps capability supports the operating range of many legacy devices. Running from 3V to 5.5V permits direct use in both 3.3V and 5V systems. Because these adapters often connect to user-accessible cables, engineers should combine sensible trace routing with connector-side ESD protection and verify ground continuity between the two devices.
工程參考資料,適用於 MAX3387EEUG+T — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX3387ECUG+T |
|---|---|---|
| Package | 24-pin TSSOP | 24-pin TSSOP |
| Brand | Analog Devices | Analog Devices |
| Device Type | 3/3 RS-232 transceiver | 3/3 RS-232 transceiver |
| Supply Voltage | 3 V to 5.5 V | 3 V |
| Maximum Data Rate | 250 kbps | 250 kbps |
| Transmitter Channels | 3 channels | 3 channels |
| Receiver Channels | 3 channels | 3 channels |
| Pin Compatibility | 24-pin TSSOP reference footprint | Complete replacement with consistent terminals and package |
主要差異化特點
- Three full-duplex RS-232 channels in one interface IC (對比MAX3387ECUG+T)
- Low-voltage operation without an external negative supply (對比MAX3387ECUG+T)
- 250kbps class throughput for legacy serial links (對比MAX3387ECUG+T)
設計說明
Place the four 0.1uF charge-pump capacitors close to the pins identified in the manufacturer datasheet. Keep their ground connections short and use the recommended layout to minimize charge-pump ripple and switching noise on nearby logic. Confirm the fitted capacitor type, voltage rating, tolerance, and DC-bias behavior at the actual supply voltage; a nominal 0.1uF capacitance does not guarantee the same effective value under bias.
Do not treat RS-232 voltage levels as direct logic-level inputs. The MAX3387EEUG+T converts between digital logic and bipolar RS-232 signals, so verify receiver thresholds, transmitter polarity, signal direction, and idle states for every channel. Also check whether the attached equipment uses V.28 or V.24 signaling. Incorrect grounding or polarity can appear as intermittent communication failures even when the IC is operating properly.
Route each external RS-232 line with a continuous return path and keep it away from clocks, switching regulators, and sensitive analog inputs. Use controlled-impedance routing where cable interconnects or long PCB runs make reflections relevant. The device supports rates up to 250kbps, but connector, cable, ground, and receiver characteristics can limit reliable communication distance; validate the complete channel with its intended cable and grounding configuration.
Use the internal dual charge pump as specified, but still evaluate conducted and radiated emissions because its switching transitions can couple into shared supply or ground paths. Add local supply decoupling, maintain a compact ground return beneath the device where the package permits, and avoid routing charge-pump connections beneath sensitive signal paths. Compare emissions before and after qualification changes because adding capacitance or extending charge-pump traces can alter system noise behavior.
合規資訊
The exact compliance status for MAX3387EEUG+T was not established by the manufacturer information included in the product-page and ordering results. Confirm RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations using the current Analog Devices product documentation before environmental qualification.