MAX379CPE+ - Fault-Protected 4:1 Multiplexer | Maxim Integrated
MPN: MAX379CPE+ ✓ 啟用中MAX379CPE+ 概覽
A multiplexer is an analog switch network that routes one of several signal sources to a common output. The MAX379 belongs to the broader analog switch and multiplexer hierarchy within interface ICs. Its differential architecture is intended for paired signals, while its 4:1 configuration provides four selections per switch. The series N-channel, P-channel, and N-channel structure is specifically designed to improve protection when the device supplies are off but external input voltages remain present.
The key features of the MAX379CPE+ include its fault-tolerant input structure, two independent 4:1 circuits, and 3.5 kOhm switch resistance. Differential routing reduces the influence of common-mode effects when paired signals are measured together. The high-voltage, fault-protected design is useful when transient or powered-off conditions could otherwise stress the input network. Two circuits in one package also reduce board area compared with separate single-ended or differential switch assemblies.
Technically, the MAX379 is described as an 8-channel, high-voltage, fault-protected multiplexer. The manufacturer identifies the MAX379 as a four-channel differential, 2-of-8 multiplexer, while the MAX378 in the same family is an eight-channel single-ended, 1-of-8 device. During an unintended power-off condition, the MAX379 channels turn off and the input current falls to only a few nanoamperes. This behavior helps isolate applied signals from the internal switching path when supply power is absent.
Typical uses include automated test equipment, data-acquisition systems, battery or power-system monitoring, industrial control interfaces, and laboratory measurement equipment. The differential configuration is especially appropriate for bridge sensors, paired analog channels, and systems where a common measurement reference is required.
PCB layout should preserve the pin assignments of the 16-pin PDIP package and route high-impedance analog nodes with short, guarded traces. Check signal amplitude and fault conditions against the manufacturer operating limits before connecting external sources. Because this is a through-hole package, component height, lead spacing, and connector orientation also require mechanical validation.
This product page combines the manufacturer function description, exact distributor package and resistance information, lifecycle context, and practical guidance for selecting, sourcing, and implementing the MAX379CPE+ in analog-routing systems.
直接替換替代品,適用於 MAX379CPE+ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
MAX379CPE
✅ 直接替換📋 參考替代品(不在目錄中)
MAX379EPE
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
MAX379EPE+
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
DG412CUE+
✅ 直接替換📋 參考替代品(不在目錄中)
MAX328EPE
✅ 直接替換📋 參考替代品(不在目錄中)
MAX379CPE+ 規格
| Multiplexer Configuration | 2 circuit, 4:1 switch |
| Channel Arrangement | 8 channels, 4-channel differential 2-of-8 |
| On Resistance | 3.5 kOhm |
| Input Protection Structure | Series N-channel, P-channel, N-channel |
| Off-State Input Current | A few nA |
| Package Type | 16-pin PDIP |
| Package Shape | Rectangular |
| Mounting Method | Through-hole, non-surface-mount |
| Number of Terminals | 16 |
| Temperature Grade | Commercial |
| Number of Circuits | 2 |
| Switch Type | SP4T |
| High-Voltage Protection | Fault-protected |
| Production Status | Production |
MAX379CPE+ rectangular 腳位配置指南
MAX379CPE+(rectangular 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX379CPE+.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX379CPE+ 適用於 6 應用s: Automated Test Equipment Signal Routing, Bridge Sensor Data Acquisition, Industrial Control Signal Multiplexing, Battery Monitoring Systems, Laboratory Measurement Systems, Data Acquisition Interface Cards.
Automated Test Equipment Signal Routing
The MAX379CPE+ suits automated test equipment that must route several paired measurement channels into shared instrumentation. Its two 4:1 switch circuits provide four differential selections while occupying one 16-pin PDIP package, reducing the number of separate switch assemblies on a through-hole test fixture. The 3.5 kOhm on-resistance must be included in the measurement uncertainty budget, particularly for high-impedance sensors. The manufacturer’s fault-protected series N-channel/P-channel/N-channel structure is valuable when a fixture or external source can remain energized during a system power-down.
推薦
Bridge Sensor Data Acquisition
The MAX379CPE+ is appropriate for bridge-sensor and other paired-signal data-acquisition systems because it routes four differential selections across two internal switch circuits. Differential selection helps keep excitation and sensing paths paired when the measurement front end compares a sensor signal against a reference. Its 3.5 kOhm on-resistance can affect source loading, so the input impedance and acquisition timing should be calculated together. If the sensor wiring can experience voltage during equipment shutdown, the MAX379 fault-protected architecture adds useful isolation compared with an unprotected analog switch.
推薦
Industrial Control Signal Multiplexing
The MAX379CPE+ can reduce analog routing complexity in industrial controllers that must select among multiple paired process signals. Two 4:1 circuits share one package, allowing controller boards to route four differential channel groups without using separate switch packages. Its fault-protected structure is useful when external field wiring remains connected while control electronics are unpowered. The commercial-grade PDIP package is mechanically convenient for through-hole industrial assemblies, although the selected MAX379 suffix and its temperature rating must satisfy the enclosure’s environmental requirements.
推薦
Battery Monitoring Systems
The MAX379CPE+ can be used in battery and power-system monitoring equipment where several voltage pairs must be presented to one measurement channel. The two independent 4:1 circuits permit organized routing of paired battery-cell or rail voltages, while the high-voltage fault-protection characteristic helps manage unusual field conditions. Designers should verify the applicable signal and supply limits in the manufacturer operating table and account for the 3.5 kOhm path resistance when the monitored source has meaningful impedance. The package also allows a straightforward retrofit to existing through-hole monitoring designs.
推薦
Laboratory Measurement Systems
The MAX379CPE+ is useful in laboratory instruments that require repeatable selection among paired analog inputs. Its differential organization helps maintain symmetry between the active and reference paths, while the dual 4:1 arrangement expands a single measurement channel into eight selectable inputs. The 3.5 kOhm switch resistance should be included in precision calculations and may require high-impedance buffers when signal attenuation is critical. Its fault-protected structure also improves robustness in instrument systems where test leads can remain attached during shutdown or range changes.
推薦
Data Acquisition Interface Cards
The MAX379CPE+ can expand a legacy data-acquisition interface by selecting multiple differential channel groups through a single 16-pin PDIP device. Two 4:1 circuits provide four differential routes, which is helpful when amplifier stages, isolation amplifiers, or converters require channel selection rather than simultaneous sampling. Because the device is a multiplexer, the selected signals are routed sequentially rather than sampled concurrently. The 3.5 kOhm on-resistance, acquisition-settling time, and source impedance determine practical accuracy, so the complete analog chain must be validated at the required sampling rate.
推薦
推薦產品摘要
工程參考資料,適用於 MAX379CPE+ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX379CPE | MAX379EPE | MAX379EPE+ | DG412CUE+ | MAX328EPE |
|---|---|---|---|---|---|---|
| Package | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Microchip Technology | Maxim Integrated |
| Switch Configuration | Dual 4:1 | Dual 4:1 | Dual 4:1 | Dual 4:1 | Dual 4:1 | Dual 4:1 |
| Number of Circuits | 2 | 2 | 2 | 2 | 2 | 2 |
主要差異化特點
- Two 4:1 circuits support four differential selections (對比MAX378CPE)
- Lower on-resistance than the identified DG412CUE+ replacement (對比DG412CUE+)
- Explicit series N-channel/P-channel/N-channel fault-protection structure (對比DG412CUE+)
- Combines differential multiplexing with a 16-pin PDIP footprint (對比ADG452BRZ)
設計說明
Do not assume generic 4:1 analog-switch behavior is interchangeable with the MAX379. The MAX379 is organized as a four-channel differential 2-of-8 multiplexer with two 4:1 circuits, and its protection behavior depends on the series N-channel/P-channel/N-channel structure. Before substituting another 16-pin PDIP device, compare channel mapping, common-pin connections, enable polarity, signal polarity, supply requirements, and maximum operating voltages against the manufacturer pin and operating tables.
Route the analog inputs, outputs, common connections, and select-control traces as short as practical, with high-impedance nodes surrounded by grounded guard traces where supported by the circuit layout. Keep the 16-pin PDIP footprint and connector orientation unchanged so the component can be replaced without PCB changes. Because the package is through-hole rather than surface-mount, also verify lead pitch, drilled diameter, body clearance, and component height against the enclosure or connector mechanical drawing.
Include the 3.5 kOhm on-resistance in the acquisition error budget and check settling time against the signal source impedance and required measurement bandwidth. A higher-impedance sensor can produce a larger attenuation error than the switch resistance alone would suggest. For differential channels, preserve symmetry between paired routing paths and place any input buffers close enough to the multiplexer that leakage, capacitance, and pickup do not dominate the measurement.
The manufacturer states that when the supplies are inadvertently turned off while input voltages remain applied, the MAX379 channels turn off and input current is limited to a few nanoamperes. This fault behavior still depends on correct supply decoupling and a valid power-up sequence. Use the manufacturer’s recommended bypass capacitors, place them adjacent to the supply pins, and avoid allowing uncontrolled external-source energy to exceed the absolute-maximum ratings listed in the datasheet.
合規資訊