MCP3562RT-E/NC - 24-Bit 153.6kSPS ADC | Microchip
MPN: MCP3562RT-E/NC ✓ 啟用中MCP3562RT-E/NC 概覽
An analog-to-digital converter, or ADC, converts continuously varying analog voltages into digital values that a microcontroller or other digital controller can process. The MCP3562RT-E/NC belongs to the delta-sigma ADC class, where an internal modulator and digital filtering extract a precise conversion result from a sampled input. Within the broader hierarchy of ADC > data converter > analog signal-conditioning IC > semiconductor, it is designed for compact systems requiring high resolution and multiple analog inputs.
Key features include 24-bit resolution, four single-ended or two differential inputs, and a maximum conversion rate of 153.6 kSPS. The internal voltage reference reduces the number of external precision components, while the small 20-pin UQFN package supports space-constrained PCB layouts. The operating temperature range is -40°C to +85°C, making the device suitable for industrial and instrumentation environments when system-level requirements remain within that range.
Its delta-sigma architecture is particularly appropriate for sensor signals, process-control measurements, and other applications where high resolution and effective noise filtering are more important than very high conversion latency. The manufacturer identifies MCP3562R as the preferred pin-compatible option for new designs because that family includes the onboard voltage reference. The MCP3562RT-E/NC combines that reference with four single-ended or two differential input channels in a compact surface-mount package.
Typical uses include precision temperature and pressure monitoring, industrial sensor acquisition, laboratory instrumentation, and low-frequency energy or power measurements. Four single-ended inputs permit several sensor signals to be multiplexed into one converter, while the differential configuration supports differential sensors and rejects common-mode noise when implemented with suitable input circuitry.
When laying out the PCB, place the reference and input-network components close to their associated pins, provide a clean low-noise supply, and follow the manufacturer layout guidance for the exposed pad. Verify the selected input topology, common-mode range, data rate, and digital interface timing before fixing the system sampling strategy. The conversion-speed setting also affects digital filtering and effective noise performance.
This product page combines the manufacturer’s device description with package, interface, conversion, and environmental characteristics, then adds application guidance, comparison details, and practical design considerations for engineers evaluating the MCP3562RT-E/NC as a compact, low-noise 24-bit ADC.
直接替換替代品,適用於 MCP3562RT-E/NC — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MCP3562RT-E/NC (相同外形與佔位) — 差異在於 Internal Reference, Resolution.
MCP3562T-E/NC
✅ 直接替換聯絡詢價
查看資料表 →MCP3562RT-E/NC 最大額定值與電氣特性
| Converter Type | 24-bit delta-sigma ADC |
| 解析度 | 24 bit |
| Maximum Data Rate | 153.6 kSPS |
| Input Configuration | 4 single-ended or 2 differential input channels |
| Internal Reference | Yes |
| 供應電壓 | 3 V |
| Digital Interface | SPI |
| 封裝 | 20-pin UQFN, 3 x 3 mm |
| 安裝類型 | Surface mount |
| 工作溫度範圍 | -40°C to +85°C |
MCP3562RT-E/NC 20-pin uqfn, 3 x 3 mm 腳位配置指南
MCP3562RT-E/NC(20-pin uqfn, 3 x 3 mm 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: MCP3562RT-E/NC.
請參閱 資料表 以查看完整腳位配置。
典型應用
MCP3562RT-E/NC 適用於 6 應用s: Industrial Sensor Acquisition, Precision Temperature Monitoring, Pressure and Load Measurement, Laboratory Instrumentation, Battery-Powered Monitoring, Process Control Monitoring.
Industrial Sensor Acquisition
The MCP3562RT-E/NC fits compact industrial sensor modules that require several measurement channels without allocating space for a large converter package. Four single-ended inputs can serve grounded temperature, pressure, or level sensors, while two differential inputs support bridge or other differential sources. The 24-bit resolution and programmable data rate up to 153.6 kSPS provide flexibility between resolution and acquisition speed. Its internal reference and 3 V operation reduce supporting circuitry, while the -40°C to +85°C rating supports industrial environments. The signal chain still requires suitable input protection, filtering, grounding, and verification that each sensor signal remains within the selected input range.
Precision Temperature Monitoring
A precision temperature-control system can use the MCP3562RT-E/NC to digitize thermocouple, RTD, or thermistor signals with its four single-ended inputs. The 24-bit resolution is useful when temperature stability and low-level resolution are more important than extremely rapid sampling, and the maximum programmable rate of 153.6 kSPS provides additional timing flexibility. The internal reference simplifies the measurement subsystem, while the 20-pin UQFN package preserves board area. For best performance, use low-noise input conditioning, isolate sensitive sensor wiring from switching nodes, and calibrate the complete channel rather than relying only on converter resolution.
Pressure and Load Measurement
The MCP3562RT-E/NC is suitable for pressure, load-cell, and force measurements where the analog signal is relatively small and high-resolution conversion is valuable. Two differential channels can accept complementary outputs from suitable sensors, while the four single-ended configuration can support other analog channels in the same enclosure. The device’s 24-bit resolution can preserve fine measurement detail, and its internal reference reduces the complexity of the reference network. Differential input layout, common-mode voltage, sensor excitation stability, shielding, and digital filtering determine whether the system achieves the intended accuracy; these considerations are more important than converter resolution alone.
Laboratory Instrumentation
Laboratory instruments often combine multiple low-frequency analog channels with the need for a compact, high-resolution front end. The MCP3562RT-E/NC provides four single-ended or two differential inputs, 24-bit resolution, a programmable data rate up to 153.6 kSPS, and a 3 V operating point in a 3 x 3 mm UQFN package. This leaves more PCB area for signal conditioning, isolation, or communications. Designers should select an appropriate data rate because changing conversion speed can change digital filtering and noise behavior, and should verify the input range and acquisition sequence against the instrument’s measurement specification.
Battery-Powered Monitoring
A battery-powered environmental or asset monitor can use the MCP3562RT-E/NC to digitize several slowly changing sensor outputs within a compact 3 V design. Four single-ended channels suit voltage-divider-based sensors, and the two differential configuration can improve common-mode rejection for suitable signals. The internal reference and small package reduce component count and board area, while the broad 153.6 kSPS programmable-rate range permits the designer to choose an appropriate acquisition profile. Low-energy designs should consider the actual conversion current and standby behavior from the datasheet, disable unused channels where supported, and avoid powering continuously when periodic sampling is sufficient.
Process Control Monitoring
The MCP3562RT-E/NC can serve as the measurement section of a process-control board that monitors pressure, flow, level, or other slow analog process variables. Its 24-bit delta-sigma architecture is suited to high-resolution measurements, and the four single-ended or two differential channels provide flexibility for several sensors. A maximum programmable data rate of 153.6 kSPS leaves room for different control-loop update requirements. For reliable operation, keep the converter away from high-current switching paths, provide clean supply decoupling, establish defined analog grounding, and calibrate offset and gain after thermal stabilization. Protection and isolation requirements depend on the process environment and wiring length.
工程參考資料,適用於 MCP3562RT-E/NC — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MCP3562T-E/NC |
|---|---|---|
| Brand | Microchip Technology | Microchip Technology |
| Package | 20-pin UQFN, 3 x 3 mm | 20-pin UQFN, 3 x 3 mm |
| Converter Type | Delta-sigma ADC | Delta-sigma ADC |
| Resolution | 24 bit | 24 bit |
| Input Configuration | 4 single-ended or 2 differential input channels | 4 single-ended or 2 differential input channels |
| Sigma-Delta Paths | 2 | 1 |
主要差異化特點
- Higher converter-path count within the same documented package family (對比MCP3562T-E/NC)
- Four single-ended or two differential measurement inputs (對比MCP3562T-E/NC)
- Compact integration in a 3 V system (對比MCP3562T-E/NC)
設計說明
Use the manufacturer land pattern and exposed-pad instructions for the 20-pin UQFN package. Place the input and reference-network components close to their associated pins, keep sensitive analog traces short, and provide the supply-decoupling network specified in the datasheet. The exposed pad normally requires a continuous ground connection and an appropriate via arrangement, but the final pattern must follow the official package drawing.
Separate analog input routing from digital clock and SPI traces, particularly when converting low-level sensor signals. Use a compact, low-noise ground return and place analog filtering near the converter rather than allowing long traces to collect noise. Differential inputs need matched, carefully routed connections, and single-ended systems require particular attention to grounding and supply-return paths to prevent converter error from appearing as sensor variation.
Do not treat the 24-bit resolution label as the guaranteed effective accuracy of the complete measurement chain. Reference noise, input noise, offset error, gain error, common-mode range, data rate, filtering, sensor excitation, and PCB leakage all affect the final result. Verify the operating mode, conversion timing, channel sequence, and analog limits in the manufacturer documentation, then calibrate the assembled system under its actual operating conditions.
The MCP3562RT-E/NC operates from a 3 V supply, but the converter still requires a clean low-noise rail. Route the analog supply through the decoupling arrangement in the datasheet and keep switching-regulator nodes and high-current return paths away from the reference and input network. If the device shares a supply with digital or switching circuitry, evaluate supply ripple at the ADC pins rather than assuming a nominal 3 V rail is adequate.
合規資訊
The manufacturer product-page material does not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations for this ordering code.