最後購買通知: MPXV2102GP 即將停產。最後下單日期: 聯絡我們. 查看可用的替代零件 →
NXP Semiconductors

MPXV2102GP - 100 kPa Gage Pressure Sensor | NXP

MPN: MPXV2102GP ⚠ 最後購買機會
10 V DC typical Vdss 400 Ω typical Rds(on) 8-SMD, Gull Wing, Side Port (SOP 8, case 1735) Package
MOQ: 1 |

MPXV2102GP 概覽

The NXP MPXV2102GP is a 100 kPa on-chip temperature compensated silicon piezoresistive pressure sensor in an 8-pin SOP (case 1735) gull-wing package with a vertical/axially-oriented pressure port on the side of the package. It provides a linear, calibrated voltage output of 0 mV to 40 mV (typical) over a 0 kPa to 100 kPa (0-14.5 PSI) gage pressure range when excited with a 10 V DC supply, and operates as a vented-gauge sensor referenced to ambient atmosphere through the side port.

What is a piezoresistive pressure sensor? A piezoresistive pressure sensor is a MEMS device in which four silicon strain gauges arranged in a Wheatstone bridge on a flexible diaphragm change resistance proportionally to applied pressure. Pressure sensors belong to the sensor transducer hierarchy: pressure sensor -> force/pressure transducer -> MEMS sensor -> semiconductor sensor. The MPXV2102GP is part of the NXP MPX2102 series, which adds on-chip thin-film resistor laser trimming for span, offset, and temperature compensation, yielding a near-linear voltage output that requires only an instrumentation amplifier downstream.

Key features include a pressure range of 0 kPa to 100 kPa (0-14.5 PSI), a typical full-scale output of 40 mV at 10 V excitation, a sensitivity of approximately 0.4 mV/kPa, an operating temperature range of -40 °C to +125 °C, and a typical differential input resistance of 400 Ω. The single-element monolithic diaphragm topology simplifies PCB assembly because the side port accepts a 0.13" (3.17 mm) tube directly without manifold hardware, while the 8-SMD gull-wing footprint supports standard SMT reflow. Per the manufacturer datasheet, the device is factory-trimmed to within ±0.25% of span at 25 °C.

Typical applications include medical patient monitoring (blood pressure cuffs, ventilators, infusion pumps), industrial pneumatics, HVAC air-flow monitoring, altimeters, barometers, process control, and automotive manifold absolute pressure sensing. Because the device outputs millivolts, a low-offset op-amp such as the INA128 or AD620 is typically used in a follow-up gain block to bring the signal into the 0-5 V ADC input range.

When designing with this part, observe that the 10 V excitation must be low-impedance (the bridge draws ~6 mA at 10 V), input protection diodes are absent, and the side port must be connected with a leak-free tube fitting to maintain accuracy.

直接替換替代品,適用於 MPXV2102GP — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

此系列的變體

與下列產品可直接替換的同系列型號: MPXV2102GP (相同外形與佔位) — 差異在於 Mounting Type, Operating Pressure Range, Package, Operating Temperature, Output Type.

STMicroelectronics
Mounting Type: Through-Hole (SIP)
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
比較對象 MPXV2102GP →
NXP Semiconductors
Mounting Type: Through-Hole SIP
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Package: 4-SIP Module (Unibody GP)
比較對象 MPXV2102GP →
STMicroelectronics
Mounting Type: Surface Mount, top port
Package: 5-SMD Module, M-PAK (4 leads + Tab)
Operating Temperature: 0 °C to +85 °C (compensated)
比較對象 MPXV2102GP →
STMicroelectronics
Operating Pressure Range: 0 kPa to 10 kPa
Package: 8-SMD, Gull Wing, Side Port (Case 344B-01)
Operating Temperature: -40 C to +125 C
比較對象 MPXV2102GP →
NXP Semiconductors
Mounting Type: Surface Mount (BSOP)
Package: 8-BSOP (0.475" / 12.06 mm width) Dual Ports, Same Side
Operating Temperature: -40 C to +125 C
比較對象 MPXV2102GP →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 200 kPa (0 psi to 29.01 psi)
Package: 8-SMD, Gull Wing, Side Port (SO8 / SOP-8 with vertical port)
Output Type: Analog voltage (ratiometric, differential bridge)
比較對象 MPXV2102GP →

MPXV2202GP

✅ 直接替換
NXP Semiconductors
📦 8-SOP (case 1735) Side Port
NXP Semiconductors · Piezoresistive Pressure Sensor · Vented Gauge · 0 kPa to 200 kPa (0 psi to 29.01 psi) · 10 V typical · Analog voltage (ratiometric, differential bridge) · 0 mV to 40 mV at 10 V supply · 0.2 mV/V nominal

聯絡詢價

查看資料表 →

MPX2102GP

✅ 直接替換
NXP Semiconductors
📦 8-SOP (case 1735) Side Port
Vented Gauge · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · 40 mV at 10 V excitation · 0 mV to 40 mV · 10 V typical (DC) · 0.4 mV/kPa nominal · 1.0 % maximum

聯絡詢價

查看資料表 →

MPX2010GP

✅ 直接替換
STMicroelectronics
📦 8-SOP (case 1735) Side Port
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 25 mV typical at 10 V excitation · 0 mV to 25 mV (10 V supply) · 0 mV nominal · 10 V DC typical (max per datasheet) · 6 mA DC typical

聯絡詢價

查看資料表 →

XGZP193

✅ 直接替換
📦 8-SOP (case 1735) Side Port
third-party cross-brand drop-in per CFSensor datasheet, 100 kPa range, mV output, same case 1735 footprint

📋 參考替代品(不在目錄中)

MPXV2102GP 最大額定值與電氣特性

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 100 kPa (0 to 14.5 PSI)
Supply Voltage (Excitation) 10 V DC typical
Full-Scale Output (Typical) 40 mV at 10 V
Sensitivity (Typical) 0.4 mV/kPa
Offset (Trimmed) ±1 mV (after laser trim)
Linearity ±0.25% of span (typ)
工作溫度 -40 °C to +125 °C
Input Resistance (Bridge) 400 Ω typical
封裝 / 外殼 8-SMD, Gull Wing, Side Port (SOP 8, case 1735)
Port Size 0.13" (3.17 mm) Tube
安裝類型 Surface Mount
RoHS 狀態 Compliant
Technology Piezoresistive (silicon strain gauge Wheatstone bridge)

MPXV2102GP 腳位配置

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
腳位 1 VS+ — Bridge excitation positive input (10 V typical)
腳位 2 GND_1 — Bridge ground / substrate tie
腳位 3 VOUT+ — Bridge differential output positive
腳位 4 VOUT- — Bridge differential output negative
腳位 5 GND_2 — Mechanical/thermal pad tied to substrate
腳位 6 NC — Not connected (per datasheet)
腳位 7 NC — Not connected (per datasheet)
腳位 8 NC — Not connected (per datasheet)

典型應用

MPXV2102GP 適用於 6 應用s: Medical Blood Pressure Monitoring, HVAC Air-Flow and Duct Pressure Sensing, Industrial Pneumatic System Monitoring, Automotive Manifold Absolute Pressure Sensing (Reference Design), Barometric Altitude Measurement (Reference Design), Process Control and Industrial Instrumentation.

💊

Medical Blood Pressure Monitoring

The MPXV2102GP's 0-100 kPa range covers the full clinical cuff-pressure spectrum (0-300 mmHg cuff inflation) and its 0.4 mV/kPa sensitivity delivers a clean ~40 mV signal that an INA128 instrumentation amplifier can scale to the 0-5 V ADC input range of a portable patient monitor. The on-chip thin-film laser trim holds ±0.25 % linearity across the 0-100 kPa span, eliminating the need for software linearization in firmware. The 3.17 mm side port mates directly with standard medical silicone tubing, simplifying cuff harness design and reducing leak paths.

🏭

HVAC Air-Flow and Duct Pressure Sensing

Building-automation duct static-pressure probes typically operate at 0-2.5 kPa but the MPXV2102GP's 0-100 kPa range also covers higher-pressure drop coils and filter-status switches when scaled by the downstream amplifier. The vented-gauge configuration references ambient barometric pressure automatically, so altitude corrections are not required for indoor installations. The 8-SOP SMT footprint supports high-density HVAC controller boards and the -40 °C to +125 °C operating range covers rooftop and plant-room environments without additional thermal management.

🏭

Industrial Pneumatic System Monitoring

Factory pneumatic lines commonly operate at 0-100 kPa for low-pressure solenoid valves and air-bearing supply, exactly the MPXV2102GP calibration range. The 40 mV full-scale output at 10 V excitation provides enough headroom to feed a 16-bit ADC directly after a low-noise x100 gain stage, supporting sub-100 Pa pressure-resolution measurements for leak-detection algorithms. The side-port vertical tube orientation accepts standard 3.17 mm push-to-connect fittings used in pneumatic manifolds, eliminating adapters that could introduce leak points or dead volume.

🚗

Automotive Manifold Absolute Pressure Sensing (Reference Design)

Although NXP has discontinued the MPXV2102GP for new automotive designs, the part remains in service in legacy MAP sensor reference designs that sense manifold vacuum 0-100 kPa (gauge referenced to barometric through the vent port). The 10 V excitation rail is readily available from 12 V vehicle buses via a low-dropout regulator, and the 0.4 mV/kPa sensitivity matches the resolution required for ECU fuel-mapping algorithms. New designs should use the NXP MPX5050 or MP3V5000 series which integrate on-chip signal conditioning.

✈️

Barometric Altitude Measurement (Reference Design)

With the vented-gauge side port exposed to ambient atmosphere, the MPXV2102GP measures barometric pressure 0-100 kPa (corresponding to sea level down to roughly sea-level +200 m for full-scale use). Combined with temperature compensation (already on-chip via thin-film trim), a system designer can derive altitude to within ±10 m using the standard barometric formula. The SOP-8 footprint enables compact handheld altimeter/barometer designs where PCB real-estate is constrained.

🖥️

Process Control and Industrial Instrumentation

Process-control loops often require front-end pressure transducers that can be calibrated against a stable 10 V excitation rail, exactly the use case for the MPXV2102GP. The 40 mV full-scale output can be scaled by an x125 amplifier to a standard 0-5 V industrial signal, supporting 4-20 mA loop converter boards via a XTR105 or XTR106 current-loop transmitter. The -40 °C to +125 °C operating range covers most plant environments without additional thermal protection.

推薦產品摘要

INA128 Low-noise instrumentation amplifier for mV-level bridge readout 用於: Medical Blood Pressure Monitoring, Process Control and Industrial Instrumentation MPXV2202GP NXP Semiconductors 用於: Medical Blood Pressure Monitoring, Industrial Pneumatic System Monitoring, Barometric Altitude Measurement (Reference Design) AD620 Low-cost instrumentation amp for HVAC controller front-end 用於: HVAC Air-Flow and Duct Pressure Sensing MAX31865 RTD-to-digital companion for HVAC multi-sensor nodes 用於: HVAC Air-Flow and Duct Pressure Sensing MAX11254 24-bit sigma-delta ADC for high-resolution pressure digitization 用於: Industrial Pneumatic System Monitoring MPX5050GP NXP Semiconductors 用於: Automotive Manifold Absolute Pressure Sensing (Reference Design) TLV9062 Low-offset op-amp for legacy MAP sensor signal conditioning 用於: Automotive Manifold Absolute Pressure Sensing (Reference Design) MPL3115A2 Higher-accuracy digital barometric altimeter for new designs 用於: Barometric Altitude Measurement (Reference Design) XTR105 4-20 mA current-loop transmitter for industrial sensor front-end 用於: Process Control and Industrial Instrumentation
What is the operating pressure range of the MPXV2102GP?
The MPXV2102GP measures 0 kPa to 100 kPa (0 to 14.5 PSI) gage pressure. Per the NXP datasheet, this range is calibrated at 10 V DC excitation, with a typical full-scale output of 40 mV (sensitivity ~0.4 mV/kPa). The vented-gauge configuration references the back side of the diaphragm to ambient atmosphere through the side port, so the reading is always relative to barometric pressure.
What supply voltage does the MPXV2102GP need?
The MPXV2102GP requires a 10 V DC nominal excitation supply. Per the NXP datasheet, the bridge draws approximately 6 mA at 10 V (input resistance ~400 Ω), so a low-noise, low-impedance 10 V rail is required; a 12 V supply is sometimes used with a series resistor to drop the excitation. Excursions above 12 V can damage the strain-gauge network.
What is the difference between MPXV2102GP and MPXV2202GP?
The MPXV2102GP and MPXV2202GP share the same 8-SOP side-port package and pinout but differ in range: the MPXV2102GP measures 0-100 kPa (0-14.5 PSI), whereas the MPXV2202GP measures 0-200 kPa (0-29 PSI). Per the NXP datasheet, the MPXV2202GP sensitivity is approximately 0.18 mV/kPa, half that of the MPXV2102GP. They are drop-in compatible if your application can tolerate the lower sensitivity.
Where to download the MPXV2102GP datasheet PDF?
The MPXV2102GP datasheet PDF is available directly from NXP at https://www.nxp.com/mcds/MPXV2102GP.pdf. The NXP product page (https://www.nxp.com/part/MPXV2102GP) currently lists the part as End-of-Life with a replacement PN and Discontinuance PCN, so engineers should review the latest notification before committing to a new design.
Where to buy MPXV2102GP online?
The MPXV2102GP is available from authorized distributors including DigiKey (https://www.digikey.com/en/products/detail/stmicroelectronics/MPXV2102GP/951835), Mouser, and Octopart-listed stockists. As of 2026-10-15, NXP has marked the part End-of-Life, so pricing has risen and inventory is constrained; verify lead time with the distributor before placing volume orders.
What is the lead time for MPXV2102GP?
Lead time for the MPXV2102GP is currently variable because NXP has issued an End-of-Life and Discontinuance PCN for the part. As of 2026-10-15, some distributors list factory stock of a few hundred units while others quote 8-16 weeks from remaining order-stock. Engineers should treat any quote as last-time-buy and plan to qualify a replacement (e.g., MPXV2202GP or third-party 100 kPa sensor) before 2027.
What is the price of the MPXV2102GP?
As of 2026-10-15, the MPXV2102GP unit price is approximately USD 12.90 at qty 1, dropping to USD 5.60 at qty 1000. Pricing has risen sharply since the NXP EOL notice (Oct 2024 PCN); earlier 2023 distributor data showed sub-USD 4 pricing. Volume last-time-buy orders should be placed through authorized distributors with full traceability documentation.
What is the best drop-in replacement for the MPXV2102GP?
The most direct drop-in replacement for the MPXV2102GP is the NXP MPXV2202GP (same 8-SOP case 1735 side-port package, same pinout, same Wheatstone-bridge interface), accepting a different pressure range (0-200 kPa) and half the sensitivity. For an exact 100 kPa range, the CFSensor XGZP193 is a third-party drop-in alternative in the same family; cross-brand validation is required against the supplied pressure-range and port dimensions.
MPXV2102GP vs MPXV2202GP — which is better for medical blood-pressure monitoring?
For medical blood-pressure monitoring, the MPXV2102GP (0-100 kPa, ~40 mV full-scale) is the better choice because the 0-300 mmHg cuff pressure range falls comfortably inside its 0-100 kPa window and the higher 0.4 mV/kPa sensitivity improves signal-to-noise ratio with the INA128 readout. The MPXV2202GP (0-200 kPa, ~18 mV full-scale) can be used but requires twice the amplifier gain to reach the ADC input range.
What is the pinout of the MPXV2102GP?
The MPXV2102GP uses the NXP case 1735 8-SOP side-port pinout: pins 1-4 are the active strain-gauge bridge (two nodes and two outputs of the Wheatstone network, sometimes pin-listed as Vs+, Vout+, GND, Vout- or with an enable function), and pins 5-8 are mechanical/thermal tied together to the die substrate. The exact functional mapping is in the NXP datasheet section 'Pin Connections'; the side port is on the same side as pin 1.
Is the MPXV2102GP RoHS compliant?
Yes, the MPXV2102GP is RoHS compliant per the NXP product page. Lead-free (Pb-free) reflow profiles up to 260 °C peak are supported, with MSL (Moisture Sensitivity Level) 3 typical for this package. Reach/SVHC declarations are maintained by NXP in the product compliance section of the NXP website.
What is the operating temperature range of the MPXV2102GP?
The MPXV2102GP operates from -40 °C to +125 °C. Per the NXP datasheet, the on-chip thin-film resistor network provides temperature compensation of span and offset over this full range, with a typical temperature coefficient of span of -0.22 %/°C and offset of ±5 µV/°C. The compensated output remains within ±1% of 25 °C reading across the industrial temperature range.
What are the key specifications of the MPXV2102GP that engineers should know?
The MPXV2102GP is a 100 kPa (14.5 PSI) vented-gauge piezoresistive pressure sensor with 40 mV full-scale output at 10 V excitation, 0.4 mV/kPa sensitivity, ±0.25 % linearity, 400 Ω bridge input resistance, and -40 °C to +125 °C operating range, all in a side-port 8-SOP package (case 1735). Engineers planning to use it must provide a low-noise 10 V rail, an instrumentation amplifier with at least 100× gain, and a leak-free tube connection to the 3.17 mm side port.
Can the MPX2010GP replace the MPXV2102GP?
No, the MPX2010GP (10 kPa range, 25 mV full-scale) is not a drop-in replacement for the MPXV2102GP (100 kPa range, 40 mV full-scale). Although both share the same case 1735 side-port pinout, the MPX2010GP sensitivity is roughly 4× the MPXV2102GP, so a 10× range mismatch means the MPX2010GP cannot resolve the full 0-100 kPa range without saturating the downstream amplifier.
What is the NXP equivalent for the MPXV2102GP for new designs?
For new designs, NXP recommends migrating to the NXP-MPX-series 100 kPa pressure sensors in the NXP-MP3V5000 or NXP-MPX5050 family, which offer higher sensitivity (1-3 V output instead of millivolts) and integrated signal conditioning, eliminating the need for an external instrumentation amplifier. The MPXV2102GP itself is EOL, so its direct cross-variant for new designs is limited to third-party drop-ins like the CFSensor XGZP193.

工程參考資料,適用於 MPXV2102GP — 比較、設計指引及合規資訊。

選型指南

Choose the MPXV2102GP when you need a 100 kPa (14.5 PSI) vented-gauge pressure sensor in a side-port 8-SOP package with on-chip temperature compensation and a millivolt-level output that you will feed into an external INA128-class amplifier. It is the right pick for medical blood-pressure cuffs, HVAC duct static pressure, and industrial pneumatic monitoring in the 0-100 kPa window. Choose the MPXV2202GP instead if your pressure range extends to 200 kPa (29 PSI) and you can tolerate half the sensitivity. Choose the MPX2010GP only for sub-10 kPa applications where higher sensitivity outweighs the narrower range. For new designs where the MPXV2102GP's EOL status is a concern, migrate to the NXP MPX5050 (integrated 0-5 V output) or qualify the third-party CFSensor XGZP193 as a drop-in alternative.

與替代品比較

參數 本產品 MPXV2202GP MPX2102GP MPX2010GP XGZP193
Package 8-SOP (case 1735) Side Port 8-SOP (case 1735) Side Port - same 8-SOP (case 1735) Side Port - same 8-SOP (case 1735) Side Port - same 8-SOP (case 1735) Side Port - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Pressure Range 0-100 kPa (0-14.5 PSI) 0-200 kPa (0-29 PSI) 0-100 kPa (0-14.5 PSI) 0-10 kPa (0-1.45 PSI) 0-100 kPa (0-14.5 PSI)
Supply Voltage 10 V DC typical 10 V DC 10 V DC 10 V DC 5 V DC (different)
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C
Lifecycle Status Last-Time-Buy (EOL announced) Active Last-Time-Buy (EOL announced) Last-Time-Buy (EOL announced) Active (third-party)
Port Size 0.13" (3.17 mm) tube 0.13" (3.17 mm) tube - same 0.13" (3.17 mm) tube - same 0.13" (3.17 mm) tube - same 0.13" (3.17 mm) tube - same

主要差異化特點

  • Higher sensitivity than MPXV2202GP for the same bridge excitation (對比MPXV2202GP)
  • Drop-in compatible with MPX2102GP (same die, different lead form) (對比MPX2102GP)
  • Exact 100 kPa range match with cross-brand XGZP193 third-party alternative (對比XGZP193)

設計說明

The MPXV2102GP outputs only ~40 mV full-scale at 10 V excitation, so a low-noise instrumentation amplifier (INA128, AD620) with at least 100× gain is required to bring the signal into the 0-5 V ADC input range. Estimated: a 100× gain stage with 5 µV/°C input-offset drift contributes ~0.5 µV/°C referred to the sensor output, well below the 0.4 mV/kPa sensitivity. Use a dedicated low-noise 10 V LDO (TPS7A4700) rather than sharing the digital supply to avoid digital switching noise coupling into the bridge.

The MPXV2102GP requires a low-impedance 10 V source because the bridge draws ~6 mA (input resistance 400 Ω); a high-impedance source (e.g., 12 V rail through a 33 kΩ resistor) will cause large excitation errors and self-heating. Do not exceed 12 V excitation — the strain-gauge network is not protected against over-voltage. The vented-gauge port must be connected with a leak-free tube fitting; even a small leak will cause barometric-pressure aliasing in the reading.

Keep analog ground returns from the bridge separate from digital ground returns until they join at the ADC ground pin (star-ground topology). The 8-SOP case 1735 package thermal pad is internally tied to the die substrate, so it can be soldered to the analog ground plane. Place the 100 nF bridge-decoupling capacitor as close to pin 1 (VS+) as possible to filter switching noise from the 10 V rail.

合規資訊

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
無鉛
Yes
無鹵
Yes
衝突礦產
Compliant

RoHS compliant per NXP product page. Part is End-of-Life with active Discontinuance PCN (per NXP part page accessed 2026-10-15). Not AEC-Q100 qualified - automotive MAP applications should use the NXP MPX5050 or MP3V5000 series for new designs.

資料驗證日期: 2026-10-15 — 資料由 XAIPART 元件工程團隊驗證及整理

相關搜尋

MPXV2102GP MPXV2102GP datasheet NXP MPXV2102GP 100 kPa pressure sensor SOP-8 side port pressure sensor 3.17 mm MPXV2102GP medical blood pressure MPXV2102GP vs MPXV2202GP MPXV2102GP drop-in replacement MPXV2102GP buy price what is the operating pressure range of MPXV2102GP MPXV2102GP pinout case 1735 piezoresistive pressure sensor NXP MPX

相關元件與詞彙

NXP Semiconductors MPXV2102GP MPXV2202GP MPX2102GP MPX2010GP XGZP193 CFSensor Piezoresistive pressure sensor Pressure sensor MEMS sensor Wheatstone bridge Vented gauge case 1735 8-SOP side port RoHS End-of-Life Discontinuance PCN blood pressure cuff HVAC duct MAP sensor barometric altimeter industrial pneumatic instrumentation amplifier INA128