TJA1441DT/0Z - 5 Mbit/s CAN FD Transceiver | NXP
MPN: TJA1441DT/0Z ✓ 啟用中TJA1441DT/0Z 概覽
The TJA1441 belongs to the NXP TJA144x family of CAN transceivers. This family provides the physical-layer interface between a CAN controller and the differential CAN bus, allowing a host processor or dedicated CAN controller to exchange frames with other nodes. The family includes single-channel devices such as the TJA1441, TJA1442 and TJA1443, as well as the dual-channel TJA1448. Supporting CAN FD enables the transceiver to participate in networks carrying larger payloads and higher data rates than Classical CAN.
The TJA1441DT/0Z includes selectable operating behavior described in the manufacturer documentation as Silent mode and selectable Off mode. These functions are useful in automotive and industrial CAN networks where a node may need to reduce bus activity, enter a low-power state, or control when its transmitter is connected to the bus. The transceiver also supports fault-tolerant CAN bus operation, an important characteristic for systems exposed to wiring faults, shorts, or excessive bus loading.
Typical applications include electronic control units, body and chassis controllers, gateway modules, instrumentation, industrial automation equipment, diagnostic tools and CAN FD gateways. In these systems, the transceiver translates the controller's TXD logic signal into the differential CANH and CANL bus levels and converts received bus activity into an RXD signal for the controller.
For PCB layout, place the transceiver close to the CAN connector or bus-header interface and keep the CANH and CANL routing symmetrical. Provide a solid ground-plane connection and follow the decoupling recommendations in the manufacturer datasheet. The bus network must also satisfy the termination, cable-length and topology requirements for the selected CAN communication standard.
This product page combines the NXP family description, verified distributor identifiers, package information, replacement guidance and application-specific design considerations. It also provides drop-in alternatives identified from the available cross-reference information, allowing engineers to compare same-package candidates before changing an existing design.
直接替換替代品,適用於 TJA1441DT/0Z — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: TJA1441DT/0Z (相同外形與佔位) — 差異在於 Package, Product Type, Supply Voltage Range, Maximum Data Rate, Receiver Hysteresis.
TJA1442AT/0Z
✅ 直接替換聯絡詢價
查看資料表 →TJA1057GTKZ
✅ 直接替換聯絡詢價
查看資料表 →TJA1441DT/0Z 規格
| Product Type | CAN FD transceiver |
| Supported Protocol | CAN and CAN FD |
| Maximum Data Rate | 5 Mbit/s |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Transceiver Configuration | 1/1 transceiver, half CANbus |
| Operating Modes | Normal mode, Silent mode and selectable Off mode |
| CAN Bus Differential Outputs | CANH and CANL |
| Controller Interface | TXD and RXD |
| 封裝 | 8-pin SO package |
| 安裝類型 | Surface mount |
| Automotive Qualification | AEC-Q100 |
TJA1441DT/0Z 8-pin so package 腳位配置指南
TJA1441DT/0Z(8-pin so package 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: TJA1441DT/0Z.
請參閱 資料表 以查看完整腳位配置。
典型應用
TJA1441DT/0Z 適用於 6 應用s: Automotive Electronic Control Units, CAN FD Automotive Gateways, Industrial CAN Automation Controllers, Vehicle Diagnostics and Test Equipment, Body and Chassis Control Modules, CAN FD Communication Hubs.
Automotive Electronic Control Units
The TJA1441DT/0Z fits automotive electronic control units that exchange controller-area-network data with body, chassis and powertrain modules. Its AEC-Q100 qualification, 4.5 V to 5.5 V supply range and CAN FD operation up to 5 Mbit/s support modern vehicle networks carrying larger payloads than Classical CAN. The transceiver provides normal, Silent and selectable Off operating modes, allowing a controller to manage bus participation and low-power states. Place it beside the CAN bus connector, route CANH and CANL as a balanced pair, and follow NXP's recommended grounding and termination arrangement.
推薦
CAN FD Automotive Gateways
The TJA1441DT/0Z is appropriate for gateway modules that translate between CAN FD and other vehicle network interfaces. Supporting rates up to 5 Mbit/s allows the gateway to sustain CAN FD traffic while its host processor handles routing and protocol conversion. Silent mode can support controlled bus participation, and selectable Off mode provides another network-state option. The 8-pin SO package supports compact controller layouts, but the designer must preserve the manufacturer's recommended pin assignments and provide stable 5 V regulation with effective local decoupling.
推薦
Industrial CAN Automation Controllers
The TJA1441DT/0Z can interface industrial automation controllers, remote I/O stations and machine-control modules with CAN FD-capable equipment. Its 5 Mbit/s maximum rate improves update throughput compared with Classical CAN, while Silent mode helps manage communication behavior during selected operating states. The device's 4.5 V to 5.5 V operating range is suitable for regulated industrial 5 V rails. Implement the bus network according to CAN topology and termination requirements, and route the differential bus pair away from switching nodes and high-current paths to preserve signal quality.
推薦
Vehicle Diagnostics and Test Equipment
The TJA1441DT/0Z is suitable for diagnostic interfaces and bench-test equipment that must connect an embedded controller to a CAN FD network. The transceiver's controller-side TXD and RXD signals fit a conventional CAN-controller arrangement, while Silent mode permits diagnostic activity without immediately driving the bus. CAN FD support up to 5 Mbit/s allows the equipment to validate modern network behavior as well as Classical CAN traffic. Designers should check controller timing, bus termination and the exact device configuration before releasing the test fixture.
推薦
Body and Chassis Control Modules
The TJA1441DT/0Z fits body and chassis control modules requiring a robust physical interface between a microcontroller and a two-wire CAN bus. CAN FD can reduce the number of frames needed for multi-sensor status information, improving network utilization without changing the transceiver's operating-voltage class. The selectable operating modes help software manage participation and shutdown behavior. Use a short, symmetrical CANH/CANL route, provide a continuous ground reference and observe the manufacturer's bus-fault and decoupling recommendations for production reliability.
推薦
CAN FD Communication Hubs
The TJA1441DT/0Z can be used in communication hubs and protocol adapters that need a standard CAN physical-layer interface. A 5 Mbit/s CAN FD capable channel supports efficient transfer of control and diagnostic data between nodes, while normal and Silent modes allow operating strategies appropriate to network management. The 8-pin SO format can simplify board-level integration where space is constrained. Confirm the hub architecture's bus-segment requirements, termination strategy and transceiver mode controls against the NXP datasheet before using the device in a multi-segment network.
推薦
推薦產品摘要
工程參考資料,適用於 TJA1441DT/0Z — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | TJA1442AT/0Z | TJA1057GTKZ |
|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Package | 8-pin SO | 8-pin SO - same | 8-pin SO - same |
| Product Type | CAN FD transceiver | CAN FD transceiver | High-speed CAN transceiver |
| CAN FD Support | Yes | Yes | No |
主要差異化特點
- Adds CAN FD capability to a high-speed CAN transceiver class (對比TJA1057GTKZ)
- Provides multiple network-state options (對比TJA1442AT/0Z)
- Uses the established 8-pin SO family footprint (對比TJA1057GTKZ)
設計說明
Place the TJA1441DT/0Z close to the CAN connector or bus-header entry point, and route CANH and CANL as a closely coupled differential pair. Keep the pair away from switching regulators, relays, motor traces and other high-current paths. Provide a low-impedance ground-plane connection and use the decoupling arrangement specified in the NXP TJA1441 datasheet.
Do not substitute a CAN FD-capable device without reviewing protocol behavior, mode-control logic and pin compatibility. NXP describes the TJA1441 as a replacement for TJA1051 and TJA1057-class transceivers, but CAN FD support changes system timing and software expectations. For an existing board, verify every package connection and confirm that the attached controller supports the selected communication mode.
Bus termination belongs at the physical ends of the CAN network rather than at every node. Keep the transceiver's bus-side connection compact, and avoid long stubs between the transceiver and connector. Use the manufacturer reference application and layout guidance when defining the CANH/CANL geometry, grounding strategy and supply-decoupling network.
合規資訊
AEC-Q100 automotive qualification is identified in the technical summary. Other environmental and material compliance declarations require confirmation from NXP or the relevant compliance documentation.