Analog Devices

AD582KD - Low-Cost Sample-and-Hold Amplifier | Analog Devices

料号: AD582KD ✓ 量产中
14-CDIP, 0.300 inch (7.62 mm) body width Package
最小起订量: 1 |

AD582KD 概述

Analog Devices AD582KD is a one-circuit sample-and-hold amplifier that combines a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier on one monolithic chip. The device samples an analog input and preserves its voltage on an external holding capacitor during the hold interval, with a 3 V/us slew rate and a 14-CDIP package measuring 0.300 inches wide by 7.62 mm long.

A sample-and-hold amplifier is an analog signal-conditioning component that captures a rapidly changing input voltage and maintains a stable value for downstream conversion, measurement, or control. Its hierarchy extends from a sample-and-hold module to an analog amplifier and then to a broader analog signal-processing IC. The AD582 architecture is useful when a signal must be held at a defined instant rather than measured continuously while it changes.

The AD582's principal benefits include its integrated operational amplifier, analog switch, and JFET integrating amplifier, together with separate analog and digital grounds. The separated grounds improve immunity to ground and switching transients, which is valuable in systems containing multiplexers, digital control logic, or switching power converters. An external holding capacitor completes the sample-and-hold function, allowing capacitance to be selected according to acquisition time, droop, and noise requirements.

Because the device is fabricated on a monolithic chip, its sampling switch, amplifier, and integrating stage operate as one coordinated circuit rather than as separately assembled blocks. The AD582KD is identified as a one-circuit device in a 14-CDIP package, and a tube is the listed packaging method for this ordering variant. Detailed acquisition time, holding droop, input impedance, output leakage, and supply-current limits should be taken directly from the Analog Devices AD582 datasheet for the operating condition being designed.

Typical uses include data acquisition, sensor-signal conditioning, pulsed measurement systems, analog-to-digital converter front ends, and instrumentation where an analog value must remain stable during conversion. The external holding capacitor is central to these applications: its value, dielectric type, leakage current, and PCB placement can determine acquisition performance, charge injection error, and hold stability.

Design the circuit with short analog input and output paths, a low-impedance return for the analog ground, and a physically small holding capacitor connected close to the relevant device pins. Review acquisition timing before increasing acquisition frequency. Also account for clock or control-signal transitions at the sample-and-hold control input because coupling from the digital domain can degrade the held value.

This product page consolidates the AD582KD architecture, package information, replacement guidance, comparison criteria, and practical application notes. The engineering guidance emphasizes the features engineers must preserve when qualifying a replacement: pin compatibility, external holding-capacitor behavior, acquisition time, hold droop, leakage, supply range, and control-input timing.

直接替换替代料: AD582KD ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: AD582KD (相同外形与封装尺寸) ——差异在于 Package, Product Type, Acquisition Time, Holding Capacitor, Mounting Type.

Analog Devices
Package: TO-100-10
Product Type: Sample-and-hold amplifier
Acquisition Time: 6 us
对比 AD582KD →
Analog Devices
Package: 14-CDIP, 0.300 in (7.62 mm) body width
Product Type: Single-channel sample-and-hold amplifier
Acquisition Time: 25 µs
对比 AD582KD →
Analog Devices
Package: 10-pin TO-100
Product Type: Integrated sample-and-hold amplifier
Acquisition Time: 25 µs
对比 AD582KD →
Analog Devices
Package: TO-100 (10-pin metal can)
Acquisition Time: 6 µs (max)

AD582SH/883B

✅ 直接替换
Analog Devices
📦 14-CDIP
Sample and Hold Amplifier · 1 · 6 µs (max) · ±15 V · 4.5 mA · -55°C to +125°C · TO-100 (10-pin metal can) · Wire

联系询价

查看数据手册 →

AD582SD

✅ 直接替换
Analog Devices
📦 14-CDIP
Single-channel sample-and-hold amplifier · 1 circuit · 25 µs · 3 V/µs · Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip · External holding capacitor · Separate analog and digital grounds · 14-CDIP, 0.300 in (7.62 mm) body width

联系询价

查看数据手册 →

AD582AD

✅ 直接替换 ⚠️ 规格未核验
📦 14-CDIP
Same AD582 sample-and-hold core and 14-CDIP mechanical family; temperature-range difference is .

📋 参考替代料(不在目录中)

AD582UD

✅ 直接替换 ⚠️ 规格未核验
📦 14-CDIP
Same AD582 family and 14-CDIP footprint; the ordering suffix changes the environmental grade, with a difference.

📋 参考替代料(不在目录中)

AD582/883B

✅ 直接替换 ⚠️ 规格未核验
📦 14-CDIP
Same AD582 core and 14-CDIP family package with MIL-STD-883 processing option; screening and environmental limits differ by .

📋 参考替代料(不在目录中)

AD582KD 最大额定值与电气特性

Product Type 1 circuit sample-and-hold amplifier
Number of Circuits 1 circuit
封装 14-CDIP, 0.300 inch (7.62 mm) body width
Slew Rate 3 V/us
Architecture Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip
Grounding Separate analog and digital grounds
Holding Capacitor External holding capacitor required
Military Qualification Versions available compliant with MIL-STD-883
Tube Packaging Tube

AD582KD 14-cdip, 0.300 inch (7.62 mm) body width 引脚配置指南

AD582KD(14-cdip, 0.300 inch (7.62 mm) body width 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

AD582KD 的 14-cdip, 0.300 inch (7.62 mm) body width 封装引脚图

暂无详细引脚数据: AD582KD.

请参阅 数据手册 以查看完整引脚配置。

典型应用

AD582KD 适用于 6 应用s: Data Acquisition Systems, Sensor Signal Conditioning, Analog-to-Digital Converter Front Ends, Pulsed Measurement Systems, Precision Instrumentation, Multiplexed Analog Systems.

🏭

Data Acquisition Systems

The AD582KD fits acquisition systems that must capture a rapidly changing analog input and hold it stable while a downstream ADC or measurement circuit operates. Its 3 V/us slew rate supports faster output transitions, while the integrated operational amplifier, analog switch, and JFET integrating amplifier reduce the number of discrete stages. According to the Analog Devices AD582 datasheet, an external holding capacitor completes the function. Select its capacitance to satisfy the acquisition interval, and place it close to the device to minimize parasitic pickup and coupling.

🧩

Sensor Signal Conditioning

The AD582KD can hold a conditioned sensor voltage during observation, control, or conversion, making it useful when the sensor output changes faster than the downstream circuit can measure it. Separate analog and digital grounds improve immunity to ground and switching transients, an important benefit in systems that also contain multiplexers or digital control circuitry. The 3 V/us slew rate supports rapid level changes, but the external holding capacitor must be selected for the sensor range, leakage requirement, and acquisition timing described by the manufacturer.

📺

Analog-to-Digital Converter Front Ends

The AD582KD is suitable ahead of an ADC when the analog input must represent the value at one defined acquisition instant rather than the value during the conversion interval. Its monolithic sample-and-hold signal path avoids assembling a discrete switch, operational amplifier, and holding network. The design must include an external holding capacitor, and the control signal must be timed so acquisition completes before the converter samples the held output. Review the AD582 datasheet for acquisition time, output range, and hold-droop limits at the intended supply voltage.

⚡

Pulsed Measurement Systems

The AD582KD supports pulsed measurement systems that compare a changing waveform with a captured reference value. Its 3 V/us slew rate allows the output to follow substantial level changes, while the JFET-based integrating stage and low-leakage switch support the storage function. The external holding capacitor remains the principal timing and stability element. In a pulsed system, verify the acquisition window, account for capacitor charging time, and route the hold-control trace away from sensitive analog nodes to reduce switching-transient errors.

🔧

Precision Instrumentation

The AD582KD can stabilize a measurement in laboratory or industrial instrumentation where the source signal changes during the measuring interval. The separate analog and digital grounds improve rejection of ground and switching transients, while the integrated monolithic circuit provides a compact one-circuit solution. According to the Analog Devices AD582 datasheet, versions with MIL-STD-883 processing are available for qualifying military programs. Select the exact suffix, package, and temperature grade before using the device in a precision measurement chain.

🌐

Multiplexed Analog Systems

The AD582KD can provide a stable analog value in a multiplexed measurement system where multiple changing inputs are selected in sequence. Separate analog and digital grounds help reduce the effect of switching transients, which is especially valuable when digital control signals determine the sampling interval. The 14-CDIP package simplifies through-hole implementation in modular instrumentation. Keep the external holding capacitor close to the device, maintain a low-impedance analog-ground return, and inspect control-edge timing to prevent acquisition errors after each multiplexer transition.

推荐产品汇总

AD582KD Analog Devices 用于: Data Acquisition Systems, Sensor Signal Conditioning, Analog-to-Digital Converter Front Ends, Pulsed Measurement Systems, Precision Instrumentation, Multiplexed Analog Systems AD582SH Analog Devices 用于: Data Acquisition Systems, Precision Instrumentation AD582SD Analog Devices 用于: Sensor Signal Conditioning AD582AD AD582-family package alternative 用于: Analog-to-Digital Converter Front Ends AD582/883B AD582-family MIL-STD-883 option 用于: Pulsed Measurement Systems AD582UD AD582-family ordering alternative 用于: Multiplexed Analog Systems
What is the AD582KD sample-and-hold amplifier used for?
The AD582KD is used to capture an analog voltage and preserve it for later measurement, control, or conversion. It combines an operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier on one monolithic chip, while an external holding capacitor completes the function. According to the Analog Devices AD582 datasheet, the separate analog and digital grounds improve immunity to ground and switching transients, making the circuit useful in data-acquisition and precision analog systems.
Where can I download the AD582KD datasheet PDF?
The AD582KD datasheet PDF is available from Analog Devices at the official AD582 data-sheet link on this page. It describes the complete sample-and-hold architecture, external holding-capacitor connection, electrical characteristics, pin assignments, and operating information. Use the PDF together with the AD582KD ordering information because the AD582 family includes different package, temperature, and military-processing options whose individual limits must match the design.
Where can I find the AD582KD pinout and 14-CDIP layout?
The AD582KD pin assignments are shown in the Analog Devices AD582 datasheet. The AD582KD uses a 14-CDIP package with a 0.300-inch, or 7.62-mm, body width. Use the manufacturer pin-description table when assigning analog inputs, hold output, control inputs, supplies, grounds, and offset-adjustment connections. The complete pin map should also be checked against the exact ordering suffix before the PCB footprint and external components are released.
What are the key specifications of AD582KD that engineers should know?
The AD582KD is a one-circuit, 3 V/us sample-and-hold amplifier in a 14-CDIP package. Its defining architecture combines a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier on a single monolithic chip. The Analog Devices AD582 datasheet also identifies separate analog and digital grounds, an external holding capacitor, and versions compliant with MIL-STD-883. Acquisition time, droop, leakage, and supply limits remain condition-specific and should be read from the manufacturer data sheet.
Does the AD582KD require an external holding capacitor?
Yes, the AD582KD requires an external holding capacitor to complete the sample-and-hold function. According to the Analog Devices AD582 datasheet, the internal monolithic circuit contains the operational amplifier, sampling switch, and JFET integrating amplifier, but the storage capacitor remains external. Its capacitance, leakage, dielectric, tolerance, and physical placement directly influence acquisition time, hold droop, offset, and susceptibility to charge injection.
What is the slew rate of the AD582KD?
The AD582KD has a slew rate of 3 V/us. This rating describes how quickly its output amplifier can change voltage when driven into a new level. It is particularly important when the sampled signal has a large amplitude change or when the amplifier must settle following acquisition. The Analog Devices AD582 datasheet should be consulted for the exact test conditions and for acquisition-time limits, because slew rate alone does not define total settling accuracy.
What is the difference between AD582KD and AD582SH?
The AD582KD and AD582SH belong to the same Analog Devices AD582 sample-and-hold family, but their ordering suffixes can denote different package or qualification configurations. The AD582KD is identified as a 14-CDIP device, while the AD582SH comparison record does not establish every ordering detail in the product listing. Confirm the package, temperature range, and MIL-STD-883 processing status in the AD582 datasheet before treating either part as a direct replacement.
What is the difference between AD582KD and AD582SD?
The AD582KD and AD582SD are both AD582-family sample-and-hold amplifier orderings, but the suffixes may identify different package or qualification configurations. The AD582KD is listed as a one-circuit 14-CDIP part, whereas the AD582SD listing does not provide enough ordering detail to confirm every mechanical and temperature characteristic. According to the Analog Devices AD582 datasheet and ordering guide, verify lead arrangement, temperature grade, and military-processing options before PCB interchangeability is assumed.
When should I choose AD582KD over another sample-and-hold amplifier?
Choose the AD582KD when the design needs a one-circuit monolithic sample-and-hold amplifier with a 14-CDIP package, an external holding capacitor, and separate analog and digital grounds. Its 3 V/us slew rate is suitable for systems that capture and then hold a changing analog value. Choose another order only after comparing acquisition time, droop, leakage, input range, supply requirements, control polarity, package dimensions, and qualification rather than relying on the generic term sample-and-hold.
Is AD582KD suitable for precision instrumentation?
The AD582KD can fit precision instrumentation when the signal amplitude, acquisition interval, leakage, and hold duration remain within its operating limits. Its monolithic operational amplifier, sampling switch, and JFET integrating stage provide an integrated signal path, while separate analog and digital grounds improve transient immunity. According to the Analog Devices AD582 datasheet, the design must also account for the external holding capacitor, whose leakage and dielectric characteristics directly influence the accuracy of the held voltage.
What is the best drop-in replacement for AD582KD?
The closest drop-in replacement is an AD582-family ordering that preserves the same 14-lead footprint, control interface, power pins, acquisition timing, and external-capacitor connection. AD582SH and AD582SD are identified as same-family comparison candidates, but the suffix-specific package and qualification details must be confirmed. According to the Analog Devices AD582 datasheet, no cross-brand substitution should be selected solely because it is also called a sample-and-hold amplifier.
Can LF398-N replace an AD582KD on the same PCB?
An LF398-N should not be assumed to be a direct AD582KD replacement without a complete pin and performance review. The cross-reference discussion concerns the two sample-and-hold functions, while the AD582KD is specified as a 14-CDIP one-circuit device. According to the Analog Devices AD582 datasheet, a valid replacement must match the board footprint, pin functions, sampling-control polarity, supply voltage, acquisition behavior, output loading, and external holding-capacitor requirements.
Where can I buy AD582KD and what is its price?
Use the Request a Quote form on this page to request AD582KD pricing, stock confirmation, lead time, and minimum-order quantity from XAIPART. The AD582KD is listed as a one-circuit 14-CDIP sample-and-hold amplifier, and its official Analog Devices datasheet should be consulted before ordering. Do not base a production BOM on a marketplace reference price because market values, package suffixes, and commercial terms can change without notice.
How long is the AD582KD lead time and is it in stock?
Request current AD582KD stock, lead time, and order quantity through the Request a Quote form on this page. The Analog Devices product page and distributor listings show AD582 family products, but current transactional status should be confirmed for the exact AD582KD suffix before production planning. Also request the tube packaging details and any temperature-grade or military-processing requirements so the confirmed supply corresponds to the exact device being designed.
Is AD582KD RoHS compliant and qualified for automotive use?
RoHS, REACH, and automotive qualification status must be confirmed from the current Analog Devices product documentation or the compliance declarations for the exact AD582KD ordering code. The Analog Devices AD582 product page states that versions compliant with MIL-STD-883 are available, which concerns military processing rather than AEC-Q100 automotive qualification. Do not infer automotive suitability from the existence of a MIL-STD-883-compatible family option.

工程参考数据: AD582KD ——对比、设计指导和合规信息。

选型指南

Choose the AD582KD for a one-circuit, through-hole sample-and-hold design that requires the AD582's integrated operational amplifier, sampling switch, JFET integrating stage, and separate analog and digital grounds. It is appropriate when the input must be captured and then held for measurement or conversion and when an external holding capacitor can be tailored to the acquisition and leakage requirements. Select AD582SH when its specific package, temperature grade, or qualification configuration matches the program better, and select AD582SD or AD582AD when their ordering limits provide the required environmental coverage. Consider AD582/883B for a MIL-STD-883-compatible version. For every candidate, verify the pin map, control timing, supply voltage, acquisition time, hold droop, leakage, output range, and package dimensions. Do not choose a cross-brand device solely from the sample-and-hold function; a valid drop-in must preserve the complete interface and performance envelope.

与替代料对比

参数 本产品 AD582SH AD582SD AD582AD AD582UD AD582/883B
Package 14-CDIP, 0.300 inch (7.62 mm) body width 14-CDIP 14-CDIP 14-CDIP 14-CDIP 14-CDIP
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Circuit Count 1 circuit 1 circuit 1 circuit 1 circuit 1 circuit 1 circuit
Product Type Sample-and-hold amplifier Sample-and-hold amplifier Sample-and-hold amplifier Sample-and-hold amplifier Sample-and-hold amplifier Sample-and-hold amplifier
Internal Architecture Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip AD582 monolithic sample-and-hold architecture AD582 monolithic sample-and-hold architecture AD582 monolithic sample-and-hold architecture AD582 monolithic sample-and-hold architecture AD582 monolithic sample-and-hold architecture
Holding Capacitor External holding capacitor required External holding capacitor required External holding capacitor required External holding capacitor required External holding capacitor required External holding capacitor required
Grounding Separate analog and digital grounds Separate analog and digital grounds Separate analog and digital grounds Separate analog and digital grounds Separate analog and digital grounds Separate analog and digital grounds

关键差异点

  • Integrated monolithic signal path (对比 AD582SH)
  • Defined low-cost one-circuit configuration (对比 AD582SD)
  • External-capacitor configuration supports design tuning (对比 AD582AD)

设计说明

Do not treat every sample-and-hold IC as a pin-compatible replacement for the AD582KD. Confirm the 14-CDIP footprint, control-input polarity, power connections, output configuration, acquisition timing, and external holding-capacitor connection. The LF398-N discussion identifies a functional alternative, but functional equivalence alone does not establish PCB compatibility. Use the Analog Devices AD582 datasheet as the controlling document for any substitution.

Place the external holding capacitor close to the device's holding-output node and route it away from the sample-and-hold control input. Keep the analog-input and hold-output traces short, provide a low-impedance analog-ground return, and separate analog and digital grounds according to the manufacturer layout guidance. Short traces and careful capacitor placement reduce parasitic pickup, control-signal feedthrough, and sensitivity to ground transients.

Time the sample-and-hold control signal so the input is fully acquired before the held output is measured or converted. The 3 V/us slew rate describes the amplifier's ability to change output level, but total settling also depends on acquisition time and the selected holding capacitor. Review droop, leakage, offset, and acquisition specifications under the intended supply voltage rather than treating the slew rate as the complete settling specification.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The Analog Devices product page states that AD582 versions compliant with MIL-STD-883 are available. No RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was established for the exact AD582KD ordering code.

数据核验日期: 2026-11-06 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

AD582KD datasheet AD582KD datasheet pdf AD582KD pinout AD582KD specifications Analog Devices AD582KD AD582KD sample hold amplifier AD582KD 14-CDIP AD582KD holding capacitor AD582KD equivalent AD582KD replacement AD582KD vs AD582SH AD582KD application circuit

相关元器件 & 术语

Analog Devices AD582KD AD582SH AD582SD AD582AD AD582UD AD582/883B sample-and-hold amplifier analog amplifier analog signal-processing IC operational amplifier low-leakage analog switch JFET integrating amplifier monolithic integrated circuit external holding capacitor slew rate acquisition time holding droop analog ground digital ground 14-CDIP MIL-STD-883
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情