AD582KD - Low-Cost Sample-and-Hold Amplifier | Analog Devices
MPN: AD582KD ✓ چالاکAD582KD گشتی
A sample-and-hold amplifier is an analog signal-conditioning component that captures a rapidly changing input voltage and maintains a stable value for downstream conversion, measurement, or control. Its hierarchy extends from a sample-and-hold module to an analog amplifier and then to a broader analog signal-processing IC. The AD582 architecture is useful when a signal must be held at a defined instant rather than measured continuously while it changes.
The AD582's principal benefits include its integrated operational amplifier, analog switch, and JFET integrating amplifier, together with separate analog and digital grounds. The separated grounds improve immunity to ground and switching transients, which is valuable in systems containing multiplexers, digital control logic, or switching power converters. An external holding capacitor completes the sample-and-hold function, allowing capacitance to be selected according to acquisition time, droop, and noise requirements.
Because the device is fabricated on a monolithic chip, its sampling switch, amplifier, and integrating stage operate as one coordinated circuit rather than as separately assembled blocks. The AD582KD is identified as a one-circuit device in a 14-CDIP package, and a tube is the listed packaging method for this ordering variant. Detailed acquisition time, holding droop, input impedance, output leakage, and supply-current limits should be taken directly from the Analog Devices AD582 datasheet for the operating condition being designed.
Typical uses include data acquisition, sensor-signal conditioning, pulsed measurement systems, analog-to-digital converter front ends, and instrumentation where an analog value must remain stable during conversion. The external holding capacitor is central to these applications: its value, dielectric type, leakage current, and PCB placement can determine acquisition performance, charge injection error, and hold stability.
Design the circuit with short analog input and output paths, a low-impedance return for the analog ground, and a physically small holding capacitor connected close to the relevant device pins. Review acquisition timing before increasing acquisition frequency. Also account for clock or control-signal transitions at the sample-and-hold control input because coupling from the digital domain can degrade the held value.
This product page consolidates the AD582KD architecture, package information, replacement guidance, comparison criteria, and practical application notes. The engineering guidance emphasizes the features engineers must preserve when qualifying a replacement: pin compatibility, external holding-capacitor behavior, acquisition time, hold droop, leakage, supply range, and control-input timing.
جێگرەوەکانی جێگۆڕکێ بۆ AD582KD — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ AD582KD (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package, Product Type, Acquisition Time, Holding Capacitor, Mounting Type.
AD582SH/883B
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →AD582SD
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →AD582AD
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD582UD
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD582/883B
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD582KD زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Product Type | 1 circuit sample-and-hold amplifier |
| Number of Circuits | 1 circuit |
| پاکێج | 14-CDIP, 0.300 inch (7.62 mm) body width |
| Slew Rate | 3 V/us |
| Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip |
| Grounding | Separate analog and digital grounds |
| Holding Capacitor | External holding capacitor required |
| Military Qualification | Versions available compliant with MIL-STD-883 |
| Tube Packaging | Tube |
ڕێنمایی ڕێکخستنی پینی AD582KD 14-cdip, 0.300 inch (7.62 mm) body width
ڕێکخستنی پین بۆ AD582KD (پاکێجی 14-cdip, 0.300 inch (7.62 mm) body width). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ AD582KD.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
AD582KD گونجاوە بۆ 6 بەکارھێنانs: Data Acquisition Systems, Sensor Signal Conditioning, Analog-to-Digital Converter Front Ends, Pulsed Measurement Systems, Precision Instrumentation, Multiplexed Analog Systems.
Data Acquisition Systems
The AD582KD fits acquisition systems that must capture a rapidly changing analog input and hold it stable while a downstream ADC or measurement circuit operates. Its 3 V/us slew rate supports faster output transitions, while the integrated operational amplifier, analog switch, and JFET integrating amplifier reduce the number of discrete stages. According to the Analog Devices AD582 datasheet, an external holding capacitor completes the function. Select its capacitance to satisfy the acquisition interval, and place it close to the device to minimize parasitic pickup and coupling.
پێشنیارکراو
Sensor Signal Conditioning
The AD582KD can hold a conditioned sensor voltage during observation, control, or conversion, making it useful when the sensor output changes faster than the downstream circuit can measure it. Separate analog and digital grounds improve immunity to ground and switching transients, an important benefit in systems that also contain multiplexers or digital control circuitry. The 3 V/us slew rate supports rapid level changes, but the external holding capacitor must be selected for the sensor range, leakage requirement, and acquisition timing described by the manufacturer.
پێشنیارکراو
Analog-to-Digital Converter Front Ends
The AD582KD is suitable ahead of an ADC when the analog input must represent the value at one defined acquisition instant rather than the value during the conversion interval. Its monolithic sample-and-hold signal path avoids assembling a discrete switch, operational amplifier, and holding network. The design must include an external holding capacitor, and the control signal must be timed so acquisition completes before the converter samples the held output. Review the AD582 datasheet for acquisition time, output range, and hold-droop limits at the intended supply voltage.
پێشنیارکراو
Pulsed Measurement Systems
The AD582KD supports pulsed measurement systems that compare a changing waveform with a captured reference value. Its 3 V/us slew rate allows the output to follow substantial level changes, while the JFET-based integrating stage and low-leakage switch support the storage function. The external holding capacitor remains the principal timing and stability element. In a pulsed system, verify the acquisition window, account for capacitor charging time, and route the hold-control trace away from sensitive analog nodes to reduce switching-transient errors.
پێشنیارکراو
Precision Instrumentation
The AD582KD can stabilize a measurement in laboratory or industrial instrumentation where the source signal changes during the measuring interval. The separate analog and digital grounds improve rejection of ground and switching transients, while the integrated monolithic circuit provides a compact one-circuit solution. According to the Analog Devices AD582 datasheet, versions with MIL-STD-883 processing are available for qualifying military programs. Select the exact suffix, package, and temperature grade before using the device in a precision measurement chain.
پێشنیارکراو
Multiplexed Analog Systems
The AD582KD can provide a stable analog value in a multiplexed measurement system where multiple changing inputs are selected in sequence. Separate analog and digital grounds help reduce the effect of switching transients, which is especially valuable when digital control signals determine the sampling interval. The 14-CDIP package simplifies through-hole implementation in modular instrumentation. Keep the external holding capacitor close to the device, maintain a low-impedance analog-ground return, and inspect control-edge timing to prevent acquisition errors after each multiplexer transition.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ AD582KD — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | AD582SH | AD582SD | AD582AD | AD582UD | AD582/883B |
|---|---|---|---|---|---|---|
| Package | 14-CDIP, 0.300 inch (7.62 mm) body width | 14-CDIP | 14-CDIP | 14-CDIP | 14-CDIP | 14-CDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Circuit Count | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Product Type | Sample-and-hold amplifier | Sample-and-hold amplifier | Sample-and-hold amplifier | Sample-and-hold amplifier | Sample-and-hold amplifier | Sample-and-hold amplifier |
| Internal Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip | AD582 monolithic sample-and-hold architecture | AD582 monolithic sample-and-hold architecture | AD582 monolithic sample-and-hold architecture | AD582 monolithic sample-and-hold architecture | AD582 monolithic sample-and-hold architecture |
| Holding Capacitor | External holding capacitor required | External holding capacitor required | External holding capacitor required | External holding capacitor required | External holding capacitor required | External holding capacitor required |
| Grounding | Separate analog and digital grounds | Separate analog and digital grounds | Separate analog and digital grounds | Separate analog and digital grounds | Separate analog and digital grounds | Separate analog and digital grounds |
جیاکەرەوە سەرەکییەکان
- Integrated monolithic signal path (بەراورد بەAD582SH)
- Defined low-cost one-circuit configuration (بەراورد بەAD582SD)
- External-capacitor configuration supports design tuning (بەراورد بەAD582AD)
تێبینییەکانی دیزاین
Do not treat every sample-and-hold IC as a pin-compatible replacement for the AD582KD. Confirm the 14-CDIP footprint, control-input polarity, power connections, output configuration, acquisition timing, and external holding-capacitor connection. The LF398-N discussion identifies a functional alternative, but functional equivalence alone does not establish PCB compatibility. Use the Analog Devices AD582 datasheet as the controlling document for any substitution.
Place the external holding capacitor close to the device's holding-output node and route it away from the sample-and-hold control input. Keep the analog-input and hold-output traces short, provide a low-impedance analog-ground return, and separate analog and digital grounds according to the manufacturer layout guidance. Short traces and careful capacitor placement reduce parasitic pickup, control-signal feedthrough, and sensitivity to ground transients.
Time the sample-and-hold control signal so the input is fully acquired before the held output is measured or converted. The 3 V/us slew rate describes the amplifier's ability to change output level, but total settling also depends on acquisition time and the selected holding capacitor. Review droop, leakage, offset, and acquisition specifications under the intended supply voltage rather than treating the slew rate as the complete settling specification.
زانیاری پابەندبوون
The Analog Devices product page states that AD582 versions compliant with MIL-STD-883 are available. No RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was established for the exact AD582KD ordering code.