AD623ANZ 概述

The Analog Devices AD623ANZ is a single-circuit instrumentation amplifier with rail-to-rail output swing, single- or dual-supply operation, and an 8-PDIP package. The verified manufacturer data specifies a supply range of 2.7 V to 12 V, with 3 V to 12 V also identified for the integrated single-supply configuration. Its gain can be programmed with one external resistor, and the device accepts industry-standard 8-lead instrumentation-amplifier pin arrangements. These characteristics make it suitable for sensor-frontend, measurement, and signal-conditioning systems where common-mode rejection and differential input handling are required.

An instrumentation amplifier is a specialized analog amplifier optimized for amplifying a small differential signal riding on a larger common-mode voltage. In the signal-chain hierarchy, an instrumentation amplifier belongs to the amplifier family and supports precision measurement, bridge excitation, biomedical instrumentation, and industrial sensing. The AD623 combines that differential-input function with rail-to-rail output capability, allowing the output to approach the supply limits under suitable load conditions.

The AD623 is designed for low-power analog systems and provides user flexibility through a single gain-setting resistor. The AD623ANZ package designation identifies the Analog Devices orderable variant listed by DigiKey as an 8-PDIP device. The manufacturer page describes rail-to-rail output swing and supply operation from 2.7 V to 12 V, while the AD623 datasheet identifies the device as a single- or dual-supply, rail-to-rail, low-cost instrumentation amplifier.

Instrumentation-amplifier performance depends on matching internal resistor networks, input bias behavior, gain accuracy, bandwidth, and the voltage headroom available around the input and output. Because the verified sources provide only high-level product and supply information, exact gain error, noise density, common-mode rejection, input bias current, bandwidth, and temperature limits must be confirmed against the manufacturer datasheet before design release. The AD623 datasheet is the authoritative source for those electrical characteristics.

Typical uses include bridge-based pressure and load sensing, low-level transducer amplification, battery-powered measurement equipment, and industrial signal conditioning. In a bridge circuit, the AD623 can amplify the small differential bridge output while rejecting the larger common-mode voltage. Designers should check input common-mode range, output swing, gain equation, supply voltage, and external resistor tolerance against the exact operating condition.

For PCB implementation, preserve the manufacturer-recommended pin assignments and provide short, low-noise routing between the sensor source, gain resistor, supply bypass network, and output receiver. A clean analog ground return and adequately decoupled supply rails help preserve measurement integrity. This page combines verified manufacturer and distributor information with engineering selection guidance, while clearly separating confirmed values from parameters still requiring datasheet confirmation.

直接替换替代料: AD623ANZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: AD623ANZ (相同外形与封装尺寸) ——差异在于 Number of Circuits, Package, RoHS Status.

Analog Devices
Number of Circuits: 1
Package: 8-SOIC (0.154 in, 3.90 mm width)
RoHS Status: Compliant
对比 AD623ANZ →

快速对比工具——选择替代料号进行并排对比:

AD623ARZ-R7

✅ 直接替换
Analog Devices
📦 8-PDIP
Instrumentation Amplifier · 1 · 2.7 V to 12 V · +/-2.5 V to +/-6 V · Rail-to-Rail · 800 kHz · 0.3 V/us · 90 dB (min) at G = 1

✓ 有现货

$2.65 / 个

查看数据手册 →

AD623BNZ

✅ 直接替换
📦 8-PDIP
Same AD623 family and 8-PDIP footprint; AD623B performance grades differ from AD623A according to the supplied cross-reference discussion, so exact gain and offset specifications require verification.

📋 参考替代料(不在目录中)

AD623ARMZ

✅ 直接替换
📦 8-SOIC
Same AD623 family but the verified package description does not establish that AD623ARMZ is an 8-PDIP; this entry is retained only as a same-family candidate pending package and pin verification.

📋 参考替代料(不在目录中)

AD623ANZ 最大额定值与电气特性

Product Type Instrumentation amplifier
Number of Circuits 1 circuit
Supply Voltage Range 2.7 V to 12 V
Single-Supply Configuration 3 V to 12 V
Dual-Supply Operation Supported
Output Swing Rail-to-rail
Gain Programming Single external gain-set resistor
封装 8-PDIP
Lead Count 8 leads
Input Signal Differential
Common-Mode Handling Instrumentation-amplifier input
Power Class Low-cost, low-power instrumentation amplifier
Product Class Rail-to-rail instrumentation amplifier
Pin Configuration Industry-standard 8-lead instrumentation-amplifier configuration
RoHS 状态 Unknown
REACH Status Unknown
AEC-Q100 Qualification Not applicable

AD623ANZ 8-pdip 引脚配置指南

AD623ANZ(8-pdip 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

AD623ANZ 的 8-pdip 封装引脚图

暂无详细引脚数据: AD623ANZ.

请参阅 数据手册 以查看完整引脚配置。

典型应用

AD623ANZ 适用于 6 应用s: Bridge-Based Pressure Sensing, Industrial Transducer Conditioning, Battery-Powered Measurement, Load-Cell Signal Conditioning, Biomedical and Diagnostic Signal Conditioning, Test and Measurement Instrumentation.

🏭

Bridge-Based Pressure Sensing

The AD623ANZ fits bridge-based pressure sensing because it is designed as a differential instrumentation amplifier rather than a general-purpose single-ended amplifier. Place it after the resistive bridge so the small differential output can be amplified while the bridge’s larger common-mode voltage is handled by the instrumentation-amplifier architecture. The verified 2.7 V to 12 V supply range supports low-voltage sensor systems, and the one-resistor gain programming simplifies setting the overall gain. Confirm the bridge excitation voltage, input common-mode range, output swing, and gain bandwidth in the AD623 datasheet before fixing the sensor interface. The 8-PDIP package is useful for through-hole laboratory, industrial, and legacy equipment where a conventional DIP footprint is preferred.

⚡

Industrial Transducer Conditioning

The AD623ANZ is appropriate for industrial transducer front ends that produce a small differential signal over a larger common-mode voltage. Its instrumentation-amplifier configuration is intended to reduce the need for several discrete precision elements in the gain path, while the single external gain-set resistor gives the designer a straightforward way to establish the required scale. The verified manufacturer description confirms single- and dual-supply operation and rail-to-rail output swing, but exact common-mode limits and gain accuracy are not present in the supplied data. The designer must therefore verify sensor excitation, signal bandwidth, supply headroom, and temperature limits in the official datasheet before production release.

🔋

Battery-Powered Measurement

The AD623ANZ can support battery-powered measurement systems because its verified supply capability extends down to 2.7 V and includes a 3 V to 12 V single-supply configuration. That range is useful for portable data-acquisition, environmental monitoring, and handheld test equipment where a higher-voltage analog rail would increase power-system complexity. The instrumentation-amplifier function is useful when a sensor produces a differential output and the system needs gain before conversion or digital processing. The actual battery operating range must be checked against minimum supply voltage, input common-mode requirements, output swing, and device-specific current consumption, which are not quantified in the supplied source snippets.

🏗️

Load-Cell Signal Conditioning

The AD623ANZ is a logical candidate for load-cell and strain-gauge front ends because these sensors generate a differential millivolt-level output and are commonly used with instrumentation amplifiers. The single gain-setting resistor simplifies the analog gain network, while the rail-to-rail output helps preserve output range in low-voltage systems. The bridge output must remain inside the AD623 input common-mode limits, and the selected gain must provide adequate signal-to-noise performance without saturating the output. Confirm the bridge excitation scheme, lead-length error, filter requirements, and exact AD623 noise and CMRR specifications in the manufacturer datasheet before choosing the final gain resistor.

💊

Biomedical and Diagnostic Signal Conditioning

The AD623ANZ may be evaluated for low-level biomedical or diagnostic signal conditioning when the sensor output is differential and the acquisition system uses a low-noise, single-supply analog front end. Its instrumentation-amplifier architecture is better matched to this task than a bare general-purpose op amp because the device is designed for differential amplification and programmable gain. However, the supplied data does not establish medical qualification, input protection, patient isolation, noise density, or safety compliance. Those requirements must be treated as unresolved and verified through the full datasheet and the applicable medical-system design process before patient-connected use.

🖥️

Test and Measurement Instrumentation

The AD623ANZ is useful in test and measurement equipment that must amplify small differential signals before an ADC or measurement converter. Its 8-PDIP package supports conventional through-hole construction and can be convenient in laboratory modules, industrial analyzers, and legacy measurement platforms. The verified manufacturer information confirms rail-to-rail output swing and 2.7 V to 12 V supply operation, allowing the amplifier to be evaluated in compact low-voltage instruments. Before layout approval, verify input range, gain accuracy, bandwidth, settling behavior, output loading, and temperature performance in the datasheet. Decoupling and grounding should follow the manufacturer’s recommended application guidance.

推荐产品汇总

AD623ANZ Analog Devices 用于: Bridge-Based Pressure Sensing, Industrial Transducer Conditioning, Battery-Powered Measurement, Load-Cell Signal Conditioning, Biomedical and Diagnostic Signal Conditioning, Test and Measurement Instrumentation AD820 Precision analog front-end companion 用于: Bridge-Based Pressure Sensing ADR4525 Precision reference for measurement systems 用于: Industrial Transducer Conditioning ADS1115 Low-power delta-sigma ADC companion 用于: Battery-Powered Measurement ADR4550 Precision excitation/reference component 用于: Load-Cell Signal Conditioning AD8605 Low-noise analog signal-chain companion 用于: Biomedical and Diagnostic Signal Conditioning ADS1256 High-resolution delta-sigma ADC 用于: Test and Measurement Instrumentation
What is the AD623ANZ?
The AD623ANZ is an Analog Devices single-circuit instrumentation amplifier in an 8-PDIP package. According to the verified Analog Devices product page, it supports single- or dual-supply operation and provides rail-to-rail output swing. Its one-resistor gain programming makes it useful for precision sensor and differential-signal conditioning designs.
What is the AD623ANZ supply voltage range?
The AD623ANZ operates from 2.7 V to 12 V according to the Analog Devices product-page description. The same verified source also identifies a 3 V to 12 V range for the integrated single-supply configuration. Actual design limits, input headroom, output headroom, and operating-region details should be checked in the AD623 datasheet.
Is the AD623ANZ rail-to-rail?
Yes. The verified Analog Devices datasheet listing describes the AD623 as a rail-to-rail instrumentation amplifier, and the manufacturer product page specifically states rail-to-rail output swing. Rail-to-rail output does not by itself guarantee rail-to-rail input operation; the applicable input common-mode limits must be verified for the selected gain and supply voltage.
How is the AD623ANZ gain programmed?
The AD623ANZ uses a single external gain-set resistor for user-programmable gain, according to the verified Analog Devices product description. The exact gain equation, resistor range, tolerance, and accuracy limits are not included in the supplied source snippets and should be taken from the manufacturer datasheet before selecting a resistor.
Can AD623ANZ work with a single supply?
Yes. The AD623 is designed for single- or dual-supply operation, and the verified manufacturer information identifies a 3 V to 12 V single-supply configuration. Single-supply use still requires checking whether the input common-mode voltage and output swing can accommodate the sensor signal at the selected gain.
Where can I download the AD623ANZ datasheet PDF?
The official AD623 datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/AD623.pdf. The verified product page is https://www.analog.com/en/products/ad623.html. These official sources should be used for the complete pin description, electrical characteristics, gain formula, and application information.
Where can I find the AD623ANZ pinout?
The AD623ANZ pinout is documented in the official AD623 datasheet and is associated with an 8-lead instrumentation-amplifier configuration. The verified distributor listing identifies the AD623ANZ as an 8-PDIP device. Use the manufacturer datasheet for exact pin numbering and descriptions rather than relying on a generic package diagram.
What can replace the AD623ANZ?
A valid replacement must use the same 8-PDIP footprint and pin arrangement and must satisfy the required gain, supply, common-mode, output-swing, noise, and bandwidth specifications. The supplied cross-reference search identifies AD623 family references, but it does not provide verified, quantified drop-in replacements. Therefore, no alternative is presented as automatically interchangeable without further manufacturer-data confirmation.
Is AD623ANZ suitable for sensor signal conditioning?
Yes, the AD623ANZ is suitable for sensor signal conditioning when the sensor produces a differential output and the selected supply and gain keep the signals within the device limits. It is especially relevant for bridge and transducer front ends because its instrumentation-amplifier architecture is intended to amplify differential signals while handling a common-mode input.
What is the difference between AD623ANZ and an ordinary op amp?
An AD623ANZ is an integrated instrumentation amplifier, whereas an ordinary operational amplifier is a general-purpose amplifier block. The instrumentation amplifier is designed around differential sensing and gain programming, while an op amp may require external resistor networks and additional precision-matched components. Exact AD623 performance figures must be confirmed in the manufacturer datasheet.
What is the AD623ANZ price?
The supplied distributor search confirms AD623ANZ availability information but does not provide a numeric price. Therefore, the pricing tiers in this record use 0.00 as an unavailable-data placeholder rather than presenting an invented quote. Check the linked DigiKey product page or request a current quotation before purchasing.
Where can I buy AD623ANZ online?
The verified DigiKey listing provides a direct purchasing page for AD623ANZ and states that the part can be ordered through that channel. The linked page is https://www.digikey.com/en/products/detail/analog-devices-inc/AD623ANZ/750974. Confirm current stock, lead time, and quantity pricing directly with the distributor.
What is the AD623ANZ lead time?
The supplied distributor snippet says the part can ship today, but it does not provide a numeric manufacturer lead time or a guaranteed inventory quantity. Treat the wording as distributor-page information rather than a universal stock commitment. Confirm the current lead time for the requested quantity before release of a production order.
Is AD623ANZ still active?
The AD623 family is presented by the verified manufacturer product page as an available Analog Devices product, and this record is classified as active based on the supplied product data. Lifecycle status can change, so confirm the latest ordering information from Analog Devices or the distributor for production planning.
What are the key AD623ANZ specifications engineers should know?
The confirmed headline specifications are one instrumentation-amplifier circuit, 2.7 V to 12 V supply operation, single- or dual-supply use, rail-to-rail output swing, one-resistor gain programming, and an 8-PDIP package. Noise, bandwidth, common-mode rejection, gain accuracy, and temperature limits are not quantified in the supplied snippets and require the official datasheet.
Can AD623ANZ be used in industrial equipment?
The AD623ANZ can be considered for industrial measurement equipment when its electrical ratings and operating-temperature requirements meet the system specification. Its instrumentation-amplifier function supports differential sensor conditioning, while the 2.7 V to 12 V supply range supports low-voltage analog systems. Industrial suitability must be confirmed against the datasheet and applicable qualification requirements.

工程参考数据: AD623ANZ ——对比、设计指导和合规信息。

选型指南

Choose AD623ANZ when the design needs a single Analog Devices instrumentation amplifier in an 8-PDIP package, operates from a low-voltage single supply or a dual supply, and benefits from one-resistor gain programming and rail-to-rail output swing. It is especially appropriate for bridge, load-cell, and other differential sensor front ends when the signal must be conditioned before an ADC. The AD623ARZ and AD623BNZ candidates may be considered only after confirming their exact package, performance grade, and pin compatibility; AD623ARMZ requires package verification because an 8-SOIC is not automatically interchangeable with an 8-PDIP PCB footprint. For production, obtain the official datasheet values for noise, CMRR, gain accuracy, bandwidth, common-mode range, and temperature, and confirm distributor pricing and lifecycle status at order time.

与替代料对比

参数 本产品 AD623ARZ AD623BNZ AD623ARMZ
Package 8-PDIP 8-PDIP 8-PDIP 8-SOIC; package not yet verified as a drop-in match
Brand Analog Devices Analog Devices Analog Devices Analog Devices
Product Type Instrumentation amplifier AD623-family instrumentation amplifier AD623-family instrumentation amplifier AD623-family instrumentation amplifier

关键差异点

  • Integrated instrumentation-amplifier function (对比 General-purpose operational amplifier)
  • Single-resistor gain programming (对比 AD623ARZ)
  • Single- and dual-supply operation (对比 AD623BNZ)
  • Rail-to-rail output swing (对比 AD623ARMZ)

设计说明

Do not assume that a replacement orderable code is interchangeable merely because it uses the AD623 family name. Verify the exact package, pin numbering, gain equation, electrical grade, supply limits, and production status in the manufacturer datasheet. In particular, AD623A and AD623B are described in the supplied cross-reference material as having separate performance-grade columns.

Keep the sensor input path short and connect the gain-set resistor close to the appropriate AD623 pins according to the manufacturer layout guidance. Use a quiet analog ground and place supply bypass capacitors near the power pins. Poor routing around a high-impedance sensor can allow interference and parasitic capacitance to distort the small differential signal before amplification.

Design the supply rail around the confirmed 2.7 V to 12 V operating range while preserving the input common-mode and output-swing headroom required by the selected gain. Do not select the gain solely from the desired equation; verify the sensor output range, bridge excitation, output load, and ADC input range so that neither input nor output saturates under worst-case conditions.

For bridge or transducer inputs, treat the differential pair as a sensitive analog signal and minimize asymmetric routing, connector noise, and long unprotected leads. Filtering should be designed around the required measurement bandwidth rather than added arbitrarily. Confirm the AD623 noise, common-mode rejection, bandwidth, and settling specifications in the official datasheet before setting the system noise target.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The supplied verified snippets do not state RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification status for AD623ANZ. These fields remain unknown rather than assumed.

数据核验日期: 2026-10-21 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

AD623ANZ AD623ANZ datasheet Analog Devices AD623ANZ AD623ANZ 8-PDIP AD623 instrumentation amplifier AD623ANZ 2.7 V to 12 V AD623ANZ rail-to-rail output AD623ANZ single supply AD623ANZ bridge sensor amplifier AD623ANZ load cell signal conditioning AD623ANZ vs AD623ARZ AD623ANZ vs AD623BNZ AD623ANZ drop-in replacement AD623ANZ price Where to buy AD623ANZ

相关元器件 & 术语

Analog Devices AD623ANZ AD623 AD623ARZ AD623BNZ AD623ARMZ instrumentation amplifier differential amplifier analog amplifier integrated circuit rail-to-rail output single-supply operation dual-supply operation programmable gain 8-PDIP DIP package bridge sensor load cell pressure transducer common-mode voltage signal conditioning single gain-set resistor sensor measurement AD623 datasheet
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情