AD625JNZ - Low-Noise Instrumentation Amplifier | Analog Devices
料号: AD625JNZ ✓ 量产中AD625JNZ 概述
An instrumentation amplifier is a precision amplifier optimized for small differential signals superimposed on a much larger common-mode voltage. Its internal architecture combines differential input stages, high common-mode rejection, and user-programmable gain. This makes the AD625JNZ suitable for sensor interfaces, bridge amplifiers, biomedical instrumentation, and industrial measurement equipment where signal integrity and gain accuracy are more important than minimum cost.
Programmable gain is set with an external resistor, allowing circuit designers to select gains that are difficult to obtain with conventional fixed-gain amplifiers. The AD625 family is particularly useful when nonstandard gain values, low noise, high common-mode rejection, and low drift are required together. Its 0.02% gain-error figure supports repeatable calibration across programmable operating ranges.
The AD625JNZ provides a 3 dB bandwidth of 650 kHz, a slew rate of 5 V/µs, and a 15 µs settling time. Input bias current is 30 nA, while the listed supply current is 3.5 mA. These characteristics balance signal speed with low noise and moderate power consumption, making the device appropriate for precision analog front ends rather than high-speed RF or general-purpose switching applications.
Typical uses include weighing systems, laboratory instrumentation, current-loop receivers, strain-gauge and resistance bridge front ends, medical monitoring equipment, and factory test systems. The AD625JNZ is particularly useful when the source impedance is moderately high and the common-mode voltage varies, because differential amplification and common-mode rejection occur inside a dedicated precision device.
Designers should follow the manufacturer's pin-description and gain-setting tables when assigning PCB tracks and external components. Input and reference pins require careful routing, the gain resistor must meet the required accuracy and temperature coefficient, and supply bypassing should be placed close to the device. Because the PDIP package is not surface mount, assess vibration, mechanical retention, and available board area before using it in compact or rugged equipment.
This page organizes the AD625JNZ electrical characteristics, lifecycle status, pricing structure, application guidance, and verified pin-compatible family options. It also provides design notes for gain selection, reference grounding, signal-chain layout, and thermal planning so engineers can evaluate the amplifier before placing it in a production design.
直接替换替代料: AD625JNZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD625JNZ (相同外形与封装尺寸) ——差异在于 Package, Slew Rate, Common-Mode Rejection Ratio, Gain Configuration, Maximum Low Nonlinearity.
AD625JNZ 最大额定值与电气特性
| Product Type | Single-channel precision instrumentation amplifier |
| Number of Channels | 1 channel |
| Maximum Supply Voltage | ±18 V |
| Supported Supply Range | -18 V to -6 V or +6 V to +18 V |
| Gain Configuration | Programmable with an external resistor |
| Gain Error | 0.02% |
| 3 dB Bandwidth | 650 kHz |
| Slew Rate | 5 V/µs |
| Settling Time | 15 µs |
| Input Noise Density | 4 nV/√Hz at 1 kHz |
| Input Bias Current | 30 nA |
| Common-Mode Rejection Ratio | 70 dB |
| 电源电流 | 3.5 mA |
| Gain Drift | 50 µV/°C |
| 工作温度范围 | 0°C to +70°C |
| 封装 | 16-pin PDIP |
| Protection | ESD protection |
| 安装类型 | Through-hole |
| RoHS 状态 | Compliant |
AD625JNZ 16-pin pdip 引脚配置指南
AD625JNZ(16-pin pdip 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD625JNZ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD625JNZ 适用于 6 应用s: Strain-Gauge Bridge Measurement, Precision Weigh Scale Signal Chain, Medical Signal Acquisition, Laboratory Instrumentation, Current-Shunt Monitor, Industrial Sensor Interface.
Strain-Gauge Bridge Measurement
The AD625JNZ fits strain-gauge and resistive-bridge front ends because it combines a 0.02% listed gain error with 4 nV/√Hz input noise at 1 kHz and the common-mode rejection expected from a dedicated instrumentation amplifier. It is placed between the bridge sensor and a downstream converter, with gain selected by an external resistor. The design trade-off is that the 650 kHz bandwidth and 15 µs settling time favor moderate-rate measurement rather than high-speed impact or dynamic testing.
推荐
Precision Weigh Scale Signal Chain
The AD625JNZ is appropriate for load-cell and weighing systems in which a small differential sensor signal must be extracted from a larger common-mode voltage. Its instrumentation-amplifier topology supports the 70 dB listed CMRR, while the 30 nA input bias current and 4 nV/√Hz noise density help limit errors from high-impedance sensors. Use a stable excitation source and carefully routed gain resistor; the 650 kHz bandwidth is more than adequate for static or slowly changing load measurements.
推荐
Medical Signal Acquisition
The AD625JNZ can form the analog input stage of a low-level medical monitoring system because its 4 nV/√Hz noise density and 0.02% gain error support accurate acquisition of small physiological signals. Place the device close to the sensor connector, reference its input network to the selected excitation or bias source, and keep sensitive nodes away from switching supplies. Medical suitability remains application-specific and must include independent review of protection, safety, qualification, and patient-circuit requirements.
推荐
Laboratory Instrumentation
The AD625JNZ is useful in laboratory measurement equipment that needs programmable gain, low input noise, and good common-mode rejection. It can amplify a sensor or differential source ahead of an ADC while the external gain resistor establishes the required range. Its 650 kHz bandwidth, 5 V/µs slew rate, and 15 µs settling time support general-purpose precision acquisition, but the PDIP package and approximately 3.5 mA listed supply current make it more appropriate for bench modules than compact handheld products.
推荐
Current-Shunt Monitor
The AD625JNZ can monitor a current shunt by amplifying its small differential voltage while rejecting the supply or common-mode voltage present across the shunt path. The 70 dB listed CMRR helps separate the desired differential measurement from common-mode disturbance, and the 30 nA input bias current minimizes error in high-resistance measurement paths. Keep the shunt connections short and symmetrical, use Kelvin routing where possible, and recognize that the 650 kHz bandwidth favors bandwidth over ultra-low-power operation.
推荐
Industrial Sensor Interface
The AD625JNZ supports industrial sensor interfaces that combine low-level differential signals with substantial common-mode voltage. Its 0.02% listed gain error supports repeatable channel calibration, while 4 nV/√Hz input noise and 70 dB CMRR improve signal recovery before digitization. The external gain network enables range selection without changing the amplifier package. For long cable runs or noisy factory environments, add suitable input protection and filtering, and route reference and feedback paths away from switching nodes.
推荐
工程参考数据: AD625JNZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD625KNZ | AD625AD |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP |
| Product Type | Precision instrumentation amplifier | Precision instrumentation amplifier | AD625 family instrumentation amplifier |
关键差异点
- Higher listed common-mode rejection in the related AD625KNZ (对比 AD625KNZ)
- Identical listed bandwidth and slew rate within the AD625 PDIP family (对比 AD625KNZ)
- Externally programmable gain supports nonstandard measurement ranges (对比 AD625AD)
设计说明
Route the two differential inputs as a closely matched pair and minimize the distance between the source, input pins, gain-setting resistor, and feedback components. Keep the reference and feedback returns quiet and avoid routing them beside digital clocks, relay contacts, or switching-power nodes. Because the device uses a sensitive high-impedance architecture, leakage from board contamination or flux residue can create offsets that are much larger than the intended input signal.
Place the manufacturer-recommended supply bypass capacitors directly across the positive and negative supply pins, using short traces and a low-impedance ground return. Keep the supply loop small and separate sensitive reference paths from regulator switching currents. The listed 3.5 mA supply current indicates that analog noise performance can be affected by supply ripple even when average power consumption appears modest.
Include gain-resistor tolerance and temperature coefficient in the amplitude-error calculation rather than relying only on the amplifier’s 0.02% gain-error figure. Confirm the selected resistor value against the AD625 gain table and recalculate after accounting for source impedance and parasitic resistance. Also verify that signal amplitude, input common-mode voltage, and output swing remain inside the device operating limits at every programmed gain.
合规信息
RoHS compliance is identified for the AD625JNZ. REACH, lead-free status, halogen-free status, and conflict-minerals status were not established for the exact ordering code.