Analog Devices

AD625JNZ - Low-Noise Instrumentation Amplifier | Analog Devices

MPN: AD625JNZ ✓ 啟用中
±18 V Vdss 30 nA Id 16-pin PDIP Package
MOQ: 1 |

AD625JNZ 概覽

The Analog Devices AD625JNZ is a single-channel, programmable-gain precision instrumentation amplifier rated for dual supply voltages up to ±18 V, with 650 kHz bandwidth, 5 V/µs slew rate, and 4 nV/√Hz input noise at 1 kHz. The device is packaged in a 16-pin PDIP package for through-hole instrumentation, measurement, and signal-conditioning systems.

An instrumentation amplifier is a precision amplifier optimized for small differential signals superimposed on a much larger common-mode voltage. Its internal architecture combines differential input stages, high common-mode rejection, and user-programmable gain. This makes the AD625JNZ suitable for sensor interfaces, bridge amplifiers, biomedical instrumentation, and industrial measurement equipment where signal integrity and gain accuracy are more important than minimum cost.

Programmable gain is set with an external resistor, allowing circuit designers to select gains that are difficult to obtain with conventional fixed-gain amplifiers. The AD625 family is particularly useful when nonstandard gain values, low noise, high common-mode rejection, and low drift are required together. Its 0.02% gain-error figure supports repeatable calibration across programmable operating ranges.

The AD625JNZ provides a 3 dB bandwidth of 650 kHz, a slew rate of 5 V/µs, and a 15 µs settling time. Input bias current is 30 nA, while the listed supply current is 3.5 mA. These characteristics balance signal speed with low noise and moderate power consumption, making the device appropriate for precision analog front ends rather than high-speed RF or general-purpose switching applications.

Typical uses include weighing systems, laboratory instrumentation, current-loop receivers, strain-gauge and resistance bridge front ends, medical monitoring equipment, and factory test systems. The AD625JNZ is particularly useful when the source impedance is moderately high and the common-mode voltage varies, because differential amplification and common-mode rejection occur inside a dedicated precision device.

Designers should follow the manufacturer's pin-description and gain-setting tables when assigning PCB tracks and external components. Input and reference pins require careful routing, the gain resistor must meet the required accuracy and temperature coefficient, and supply bypassing should be placed close to the device. Because the PDIP package is not surface mount, assess vibration, mechanical retention, and available board area before using it in compact or rugged equipment.

This page organizes the AD625JNZ electrical characteristics, lifecycle status, pricing structure, application guidance, and verified pin-compatible family options. It also provides design notes for gain selection, reference grounding, signal-chain layout, and thermal planning so engineers can evaluate the amplifier before placing it in a production design.

直接替換替代品,適用於 AD625JNZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

此系列的變體

與下列產品可直接替換的同系列型號: AD625JNZ (相同外形與佔位) — 差異在於 Package, Slew Rate, Common-Mode Rejection Ratio, Gain Configuration, Maximum Low Nonlinearity.

Analog Devices
Package: 16-CDIP
Maximum Low Nonlinearity: 0.001% max
比較對象 AD625JNZ →
Analog Devices
Package: 16-CDIP, 0.300-inch (7.62 mm) width
Maximum Low Nonlinearity: 0.001%
比較對象 AD625JNZ →
Analog Devices
Slew Rate: 5 V/us
Common-Mode Rejection Ratio: 75 dB
Gain Configuration: User-selectable
比較對象 AD625JNZ →

AD625KNZ

✅ 直接替換
Analog Devices
📦 16-pin PDIP
Single-channel precision instrumentation amplifier · 1 channel · 50 uV · 5 V/us · 25 MHz · 650 kHz · +/-6 V to +/-18 V · 16-pin PDIP

聯絡詢價

查看資料表 →

AD625AD

✅ 直接替換
Analog Devices
📦 16-pin PDIP
Programmable-gain instrumentation amplifier · 1 circuit · 1 to 10,000 · 0.02% max · 5 ppm/°C max · 0.001% max · 200 µV · 4 nV/√Hz at 1 kHz

聯絡詢價

查看資料表 →

AD625JNZ 最大額定值與電氣特性

Product Type Single-channel precision instrumentation amplifier
Number of Channels 1 channel
Maximum Supply Voltage ±18 V
Supported Supply Range -18 V to -6 V or +6 V to +18 V
Gain Configuration Programmable with an external resistor
Gain Error 0.02%
3 dB Bandwidth 650 kHz
Slew Rate 5 V/µs
Settling Time 15 µs
Input Noise Density 4 nV/√Hz at 1 kHz
Input Bias Current 30 nA
Common-Mode Rejection Ratio 70 dB
供應電流 3.5 mA
Gain Drift 50 µV/°C
工作溫度範圍 0°C to +70°C
封裝 16-pin PDIP
Protection ESD protection
安裝類型 Through-hole
RoHS 狀態 Compliant

AD625JNZ 16-pin pdip 腳位配置指南

AD625JNZ(16-pin pdip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。

AD625JNZ 的 16-pin pdip 封裝腳位圖

無詳細腳位定義資料: AD625JNZ.

請參閱 資料表 以查看完整腳位配置。

典型應用

AD625JNZ 適用於 6 應用s: Strain-Gauge Bridge Measurement, Precision Weigh Scale Signal Chain, Medical Signal Acquisition, Laboratory Instrumentation, Current-Shunt Monitor, Industrial Sensor Interface.

🏭

Strain-Gauge Bridge Measurement

The AD625JNZ fits strain-gauge and resistive-bridge front ends because it combines a 0.02% listed gain error with 4 nV/√Hz input noise at 1 kHz and the common-mode rejection expected from a dedicated instrumentation amplifier. It is placed between the bridge sensor and a downstream converter, with gain selected by an external resistor. The design trade-off is that the 650 kHz bandwidth and 15 µs settling time favor moderate-rate measurement rather than high-speed impact or dynamic testing.

⚖️

Precision Weigh Scale Signal Chain

The AD625JNZ is appropriate for load-cell and weighing systems in which a small differential sensor signal must be extracted from a larger common-mode voltage. Its instrumentation-amplifier topology supports the 70 dB listed CMRR, while the 30 nA input bias current and 4 nV/√Hz noise density help limit errors from high-impedance sensors. Use a stable excitation source and carefully routed gain resistor; the 650 kHz bandwidth is more than adequate for static or slowly changing load measurements.

💊

Medical Signal Acquisition

The AD625JNZ can form the analog input stage of a low-level medical monitoring system because its 4 nV/√Hz noise density and 0.02% gain error support accurate acquisition of small physiological signals. Place the device close to the sensor connector, reference its input network to the selected excitation or bias source, and keep sensitive nodes away from switching supplies. Medical suitability remains application-specific and must include independent review of protection, safety, qualification, and patient-circuit requirements.

🔧

Laboratory Instrumentation

The AD625JNZ is useful in laboratory measurement equipment that needs programmable gain, low input noise, and good common-mode rejection. It can amplify a sensor or differential source ahead of an ADC while the external gain resistor establishes the required range. Its 650 kHz bandwidth, 5 V/µs slew rate, and 15 µs settling time support general-purpose precision acquisition, but the PDIP package and approximately 3.5 mA listed supply current make it more appropriate for bench modules than compact handheld products.

⚡

Current-Shunt Monitor

The AD625JNZ can monitor a current shunt by amplifying its small differential voltage while rejecting the supply or common-mode voltage present across the shunt path. The 70 dB listed CMRR helps separate the desired differential measurement from common-mode disturbance, and the 30 nA input bias current minimizes error in high-resistance measurement paths. Keep the shunt connections short and symmetrical, use Kelvin routing where possible, and recognize that the 650 kHz bandwidth favors bandwidth over ultra-low-power operation.

🏭

Industrial Sensor Interface

The AD625JNZ supports industrial sensor interfaces that combine low-level differential signals with substantial common-mode voltage. Its 0.02% listed gain error supports repeatable channel calibration, while 4 nV/√Hz input noise and 70 dB CMRR improve signal recovery before digitization. The external gain network enables range selection without changing the amplifier package. For long cable runs or noisy factory environments, add suitable input protection and filtering, and route reference and feedback paths away from switching nodes.

What is the operating voltage of AD625JNZ?
The AD625JNZ operates from dual supplies of +6 V to +18 V and -6 V to -18 V, allowing a maximum total supply span of 36 V. According to the Analog Devices AD625 product documentation, the device is intended for conventional bipolar analog supplies rather than single-supply operation. Both supply rails must remain within their specified operating limits, and adequate bypassing should be placed close to the supply pins.
What are the key specifications of AD625JNZ?
The AD625JNZ combines a 650 kHz 3 dB bandwidth, 5 V/µs slew rate, 15 µs settling time, and 4 nV/√Hz input noise density at 1 kHz. Its listed gain error is 0.02%, supply current is 3.5 mA, and input bias current is 30 nA. The Analog Devices product documentation identifies it as a single-channel, externally programmable-gain instrumentation amplifier in a 16-pin PDIP package.
Where can I download the AD625JNZ datasheet PDF?
The official AD625JNZ technical documentation is available through the Analog Devices AD625 product page at https://www.analog.com/en/products/ad625.html. The manufacturer page provides the data sheet and product resources for the AD625 family. For the exact production ordering code, use the AD625JNZ row and confirm the PDIP-16 package, temperature grade, and ordering information before releasing a design for production.
Where can I find the AD625JNZ pinout?
The AD625JNZ pinout is documented in the pin-configuration section of the Analog Devices AD625 data sheet. Use the package drawing associated with the 16-pin PDIP rather than a ceramic-package pinout, because the AD625 family uses different ordering suffixes for different package constructions. Assign PCB connections from the manufacturer pin-description table, including power, ground, reference, feedback, and gain-setting terminals.
How is the gain set on an AD625JNZ?
The AD625JNZ uses an external resistor to establish its programmable gain. The manufacturer documentation describes the AD625 as an instrumentation amplifier for nonstandard and software-programmable gain applications, where a resistor-controlled gain network supports selectable measurement ranges. Select the resistor using the gain equation and resistor table in the data sheet, and include resistor tolerance and temperature drift in the total gain-error budget.
Is AD625JNZ suitable for strain-gauge and bridge measurements?
Yes, the AD625JNZ is suitable for strain-gauge and resistive-bridge front ends because its precision instrumentation-amplifier architecture is designed to amplify small differential signals with high common-mode rejection. The listed 0.02% gain error and 4 nV/√Hz input noise at 1 kHz support accurate low-level measurements. Bridge excitation, input protection, reference grounding, and gain-resistor stability still require careful implementation.
AD625JNZ vs AD625KNZ: which is better for a new design?
The AD625JNZ is the appropriate choice when the AD625 family is selected for a 16-pin PDIP design and its listed commercial operating range of 0°C to +70°C is sufficient. The AD625KNZ is a related PDIP option whose listed CMRR is 110 dB versus 70 dB for the AD625JNZ. For applications requiring the higher CMRR, confirm temperature grade, availability, and exact ordering details before choosing between them.
What is the difference between AD625JNZ and AD625ADZ?
The AD625JNZ uses a 16-pin PDIP package, while the AD625ADZ uses a 16-pin CDIP package according to a published package comparison. Their package dimensions and mounting constructions differ, so the AD625ADZ is not a same-footprint drop-in replacement for the AD625JNZ. Both belong to the AD625 precision instrumentation-amplifier family, but PCB outline, height, and connector clearance must be checked separately.
When should I choose AD625JNZ instead of AD625KNZ?
Choose the AD625JNZ when a plastic 16-pin PDIP package and a listed 0°C to +70°C commercial operating range are suitable, particularly when the design does not require the AD625KNZ's listed 110 dB CMRR. Choose the AD625KNZ when common-mode rejection is the overriding requirement. Confirm exact electrical limits, temperature grade, lifecycle status, and the mechanical outline for the selected ordering code.
What can replace AD625JNZ?
A replacement must preserve the 16-pin PDIP footprint, pin functions, supply range, gain-setting method, bandwidth, and required common-mode performance. The AD625KNZ is the closest verified family alternative because it uses the same PDIP format and provides a listed 110 dB CMRR, compared with 70 dB for the AD625JNZ. The AD625ADZ is not a drop-in choice because it uses CDIP rather than PDIP construction.
Is AD625JNZ suitable for medical monitoring equipment?
The AD625JNZ can be used in medical monitoring signal chains when its electrical characteristics, operating range, and applicable device qualification satisfy the system requirements. Its 4 nV/√Hz input noise at 1 kHz, 0.02% gain error, and instrumentation-amplifier common-mode rejection are useful for low-level physiological sensing. Medical designs must independently verify safety, reliability, patient protection, and the required quality status.
How should I handle power supply bypassing for AD625JNZ?
Place the recommended bypass capacitors immediately across the positive and negative supply pins, with short ground returns and no long loops between the capacitor and the PDIP leads. According to the AD625 manufacturer's application guidance, stable reference and supply connections are fundamental to preserving low-noise operation. Check the data sheet for the recommended capacitance and ESR characteristics before finalizing the layout.
Is AD625JNZ currently active for new designs?
The AD625JNZ should be treated as not recommended for new designs despite being listed as an active catalog part. The Analog Devices product page explicitly states “AD625 NOT RECOMMENDED FOR NEW DESIGNS.” Existing designs may continue using the device subject to lifecycle and sourcing review, while new programs should evaluate a currently recommended precision instrumentation amplifier with the required package and gain architecture.
Where to buy AD625JNZ online?
Use the Request a Quote form on this page to request AD625JNZ pricing, stock confirmation, lot traceability, and lead time for the exact 16-pin PDIP ordering code. Quote requests should state the required quantity, authorized-channel preference, and whether the tube packaging is acceptable. This avoids ambiguity between the AD625 family’s different ceramic, plastic, and temperature-grade ordering options.
What is the price of AD625JNZ?
Current AD625JNZ pricing is obtained through the Request a Quote form on this page because pricing can vary with quantity, inventory, and package format. Submit the exact MPN AD625JNZ and request a quantity-break quotation. The form can also confirm whether the available AD625JNZ inventory is packaged in the required tube configuration and whether any lot or date-code constraints apply.
What is the lead time and stock status for AD625JNZ?
Current stock and lead time for AD625JNZ should be confirmed through the Request a Quote form on this page. Provide the required quantity, target delivery date, acceptable packaging, and traceability requirements so the supplier can check the exact 16-pin PDIP device rather than another AD625 package option. Because the family is not recommended for new designs, request lifecycle confirmation when allocating inventory for a production program.

工程參考資料,適用於 AD625JNZ — 比較、設計指引及合規資訊。

選型指南

Choose the AD625JNZ for an existing or legacy 16-pin PDIP design that needs the listed 0.02% gain error, 4 nV/√Hz input noise, 650 kHz bandwidth, and 70 dB CMRR. The AD625KNZ is the stronger option when common-mode rejection is the dominant concern because it is listed at 110 dB while retaining 650 kHz bandwidth and 5 V/µs slew rate. The AD625AD is a related PDIP family option, but its ordering characteristics and complete electrical limits should be checked before substitution. The AD625ADZ is not a footprint-compatible choice because it uses CDIP construction. For new designs, account for the manufacturer’s “not recommended for new designs” designation and compare the AD625 against a currently recommended precision instrumentation amplifier. Final selection should also verify supply range, output swing, temperature grade, gain-resistor requirements, and PCB mechanical clearance.

與替代品比較

參數 本產品 AD625KNZ AD625AD
Brand Analog Devices Analog Devices Analog Devices
Package 16-pin PDIP 16-pin PDIP 16-pin PDIP
Product Type Precision instrumentation amplifier Precision instrumentation amplifier AD625 family instrumentation amplifier

主要差異化特點

  • Higher listed common-mode rejection in the related AD625KNZ (對比AD625KNZ)
  • Identical listed bandwidth and slew rate within the AD625 PDIP family (對比AD625KNZ)
  • Externally programmable gain supports nonstandard measurement ranges (對比AD625AD)

設計說明

Route the two differential inputs as a closely matched pair and minimize the distance between the source, input pins, gain-setting resistor, and feedback components. Keep the reference and feedback returns quiet and avoid routing them beside digital clocks, relay contacts, or switching-power nodes. Because the device uses a sensitive high-impedance architecture, leakage from board contamination or flux residue can create offsets that are much larger than the intended input signal.

Place the manufacturer-recommended supply bypass capacitors directly across the positive and negative supply pins, using short traces and a low-impedance ground return. Keep the supply loop small and separate sensitive reference paths from regulator switching currents. The listed 3.5 mA supply current indicates that analog noise performance can be affected by supply ripple even when average power consumption appears modest.

Include gain-resistor tolerance and temperature coefficient in the amplitude-error calculation rather than relying only on the amplifier’s 0.02% gain-error figure. Confirm the selected resistor value against the AD625 gain table and recalculate after accounting for source impedance and parasitic resistance. Also verify that signal amplitude, input common-mode voltage, and output swing remain inside the device operating limits at every programmed gain.

合規資訊

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
無鉛
Unknown
無鹵
Unknown
衝突礦產
Unknown

RoHS compliance is identified for the AD625JNZ. REACH, lead-free status, halogen-free status, and conflict-minerals status were not established for the exact ordering code.

資料驗證日期: 2026-11-18 — 資料由 XAIPART 元件工程團隊驗證及整理

相關搜尋

AD625JNZ datasheet AD625JNZ pinout AD625JNZ datasheet pdf AD625JNZ specifications AD625JNZ PDIP-16 AD625JNZ equivalent AD625JNZ replacement AD625JNZ vs AD625KNZ AD625JNZ strain gauge amplifier AD625JNZ price AD625JNZ stock Analog Devices AD625JNZ

相關元件與詞彙

Analog Devices AD625JNZ AD625KNZ AD625AD AD625ADZ precision instrumentation amplifier instrumentation amplifier differential amplifier amplifier IC integrated circuit programmable gain external-resistor gain setting common-mode rejection ratio CMRR input noise density gain error input bias current 3 dB bandwidth slew rate 16-pin PDIP PDIP package through-hole package strain-gauge bridge load-cell interface medical monitoring
快速報價 RFQ
請填寫完整詳細資料 — 我們的業務團隊將於 24 小時內回覆
料號 製造商 封裝 QTY 目標價格 小計
✓
報價已提交!

我們將於 24 小時內回覆您的電子郵件

1
詢價已提交
2
已收到報價
3
已下單
4
付款
5
已出貨
6
已送達
檢視詢價單詳情