AD625JNZ - Low-Noise Instrumentation Amplifier | Analog Devices
MPN: AD625JNZ ✓ 啟用中AD625JNZ 概覽
An instrumentation amplifier is a precision amplifier optimized for small differential signals superimposed on a much larger common-mode voltage. Its internal architecture combines differential input stages, high common-mode rejection, and user-programmable gain. This makes the AD625JNZ suitable for sensor interfaces, bridge amplifiers, biomedical instrumentation, and industrial measurement equipment where signal integrity and gain accuracy are more important than minimum cost.
Programmable gain is set with an external resistor, allowing circuit designers to select gains that are difficult to obtain with conventional fixed-gain amplifiers. The AD625 family is particularly useful when nonstandard gain values, low noise, high common-mode rejection, and low drift are required together. Its 0.02% gain-error figure supports repeatable calibration across programmable operating ranges.
The AD625JNZ provides a 3 dB bandwidth of 650 kHz, a slew rate of 5 V/µs, and a 15 µs settling time. Input bias current is 30 nA, while the listed supply current is 3.5 mA. These characteristics balance signal speed with low noise and moderate power consumption, making the device appropriate for precision analog front ends rather than high-speed RF or general-purpose switching applications.
Typical uses include weighing systems, laboratory instrumentation, current-loop receivers, strain-gauge and resistance bridge front ends, medical monitoring equipment, and factory test systems. The AD625JNZ is particularly useful when the source impedance is moderately high and the common-mode voltage varies, because differential amplification and common-mode rejection occur inside a dedicated precision device.
Designers should follow the manufacturer's pin-description and gain-setting tables when assigning PCB tracks and external components. Input and reference pins require careful routing, the gain resistor must meet the required accuracy and temperature coefficient, and supply bypassing should be placed close to the device. Because the PDIP package is not surface mount, assess vibration, mechanical retention, and available board area before using it in compact or rugged equipment.
This page organizes the AD625JNZ electrical characteristics, lifecycle status, pricing structure, application guidance, and verified pin-compatible family options. It also provides design notes for gain selection, reference grounding, signal-chain layout, and thermal planning so engineers can evaluate the amplifier before placing it in a production design.
直接替換替代品,適用於 AD625JNZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD625JNZ (相同外形與佔位) — 差異在於 Package, Slew Rate, Common-Mode Rejection Ratio, Gain Configuration, Maximum Low Nonlinearity.
AD625JNZ 最大額定值與電氣特性
| Product Type | Single-channel precision instrumentation amplifier |
| Number of Channels | 1 channel |
| Maximum Supply Voltage | ±18 V |
| Supported Supply Range | -18 V to -6 V or +6 V to +18 V |
| Gain Configuration | Programmable with an external resistor |
| Gain Error | 0.02% |
| 3 dB Bandwidth | 650 kHz |
| Slew Rate | 5 V/µs |
| Settling Time | 15 µs |
| Input Noise Density | 4 nV/√Hz at 1 kHz |
| Input Bias Current | 30 nA |
| Common-Mode Rejection Ratio | 70 dB |
| 供應電流 | 3.5 mA |
| Gain Drift | 50 µV/°C |
| 工作溫度範圍 | 0°C to +70°C |
| 封裝 | 16-pin PDIP |
| Protection | ESD protection |
| 安裝類型 | Through-hole |
| RoHS 狀態 | Compliant |
AD625JNZ 16-pin pdip 腳位配置指南
AD625JNZ(16-pin pdip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD625JNZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD625JNZ 適用於 6 應用s: Strain-Gauge Bridge Measurement, Precision Weigh Scale Signal Chain, Medical Signal Acquisition, Laboratory Instrumentation, Current-Shunt Monitor, Industrial Sensor Interface.
Strain-Gauge Bridge Measurement
The AD625JNZ fits strain-gauge and resistive-bridge front ends because it combines a 0.02% listed gain error with 4 nV/√Hz input noise at 1 kHz and the common-mode rejection expected from a dedicated instrumentation amplifier. It is placed between the bridge sensor and a downstream converter, with gain selected by an external resistor. The design trade-off is that the 650 kHz bandwidth and 15 µs settling time favor moderate-rate measurement rather than high-speed impact or dynamic testing.
推薦
Precision Weigh Scale Signal Chain
The AD625JNZ is appropriate for load-cell and weighing systems in which a small differential sensor signal must be extracted from a larger common-mode voltage. Its instrumentation-amplifier topology supports the 70 dB listed CMRR, while the 30 nA input bias current and 4 nV/√Hz noise density help limit errors from high-impedance sensors. Use a stable excitation source and carefully routed gain resistor; the 650 kHz bandwidth is more than adequate for static or slowly changing load measurements.
推薦
Medical Signal Acquisition
The AD625JNZ can form the analog input stage of a low-level medical monitoring system because its 4 nV/√Hz noise density and 0.02% gain error support accurate acquisition of small physiological signals. Place the device close to the sensor connector, reference its input network to the selected excitation or bias source, and keep sensitive nodes away from switching supplies. Medical suitability remains application-specific and must include independent review of protection, safety, qualification, and patient-circuit requirements.
推薦
Laboratory Instrumentation
The AD625JNZ is useful in laboratory measurement equipment that needs programmable gain, low input noise, and good common-mode rejection. It can amplify a sensor or differential source ahead of an ADC while the external gain resistor establishes the required range. Its 650 kHz bandwidth, 5 V/µs slew rate, and 15 µs settling time support general-purpose precision acquisition, but the PDIP package and approximately 3.5 mA listed supply current make it more appropriate for bench modules than compact handheld products.
推薦
Current-Shunt Monitor
The AD625JNZ can monitor a current shunt by amplifying its small differential voltage while rejecting the supply or common-mode voltage present across the shunt path. The 70 dB listed CMRR helps separate the desired differential measurement from common-mode disturbance, and the 30 nA input bias current minimizes error in high-resistance measurement paths. Keep the shunt connections short and symmetrical, use Kelvin routing where possible, and recognize that the 650 kHz bandwidth favors bandwidth over ultra-low-power operation.
推薦
Industrial Sensor Interface
The AD625JNZ supports industrial sensor interfaces that combine low-level differential signals with substantial common-mode voltage. Its 0.02% listed gain error supports repeatable channel calibration, while 4 nV/√Hz input noise and 70 dB CMRR improve signal recovery before digitization. The external gain network enables range selection without changing the amplifier package. For long cable runs or noisy factory environments, add suitable input protection and filtering, and route reference and feedback paths away from switching nodes.
推薦
工程參考資料,適用於 AD625JNZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD625KNZ | AD625AD |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP |
| Product Type | Precision instrumentation amplifier | Precision instrumentation amplifier | AD625 family instrumentation amplifier |
主要差異化特點
- Higher listed common-mode rejection in the related AD625KNZ (對比AD625KNZ)
- Identical listed bandwidth and slew rate within the AD625 PDIP family (對比AD625KNZ)
- Externally programmable gain supports nonstandard measurement ranges (對比AD625AD)
設計說明
Route the two differential inputs as a closely matched pair and minimize the distance between the source, input pins, gain-setting resistor, and feedback components. Keep the reference and feedback returns quiet and avoid routing them beside digital clocks, relay contacts, or switching-power nodes. Because the device uses a sensitive high-impedance architecture, leakage from board contamination or flux residue can create offsets that are much larger than the intended input signal.
Place the manufacturer-recommended supply bypass capacitors directly across the positive and negative supply pins, using short traces and a low-impedance ground return. Keep the supply loop small and separate sensitive reference paths from regulator switching currents. The listed 3.5 mA supply current indicates that analog noise performance can be affected by supply ripple even when average power consumption appears modest.
Include gain-resistor tolerance and temperature coefficient in the amplitude-error calculation rather than relying only on the amplifier’s 0.02% gain-error figure. Confirm the selected resistor value against the AD625 gain table and recalculate after accounting for source impedance and parasitic resistance. Also verify that signal amplitude, input common-mode voltage, and output swing remain inside the device operating limits at every programmed gain.
合規資訊