AD7714YRZ - 24-Bit Sigma-Delta ADC | Analog Devices
料号: AD7714YRZ ✓ 量产中AD7714YRZ 概述
An analog front end such as the AD7714 integrates input signal conditioning, a sigma-delta modulator, digital filtering, calibration, and conversion logic. Within the ADC hierarchy, it is a low-frequency precision ADC that accepts differential or pseudo-differential sensor inputs and provides a serial digital output. This integration allows a measurement system to use a small, low-power signal chain without adding a separate instrumentation amplifier or external gain stage.
Key features include conversion resolution up to 24 bits with no missing codes, typical accuracy of ±0.0015%, and low rms input noise of 140 nV. On-chip self-calibration removes zero-scale and full-scale errors as well as the effects of temperature drift. The converter supports three differential analog inputs that can alternatively be configured as five pseudo-differential inputs, together with a differential reference input for systems requiring flexible channel selection or ratiometric measurement.
The sigma-delta architecture is suited to precision rather than high-speed conversion. Its digital filtering suppresses out-of-band noise and averages successive samples to produce a stable result from low-frequency transducer outputs. Self-calibration improves repeatability by correcting offset and gain-related errors internally. The serial interface reduces the number of PCB signal lines and supports integration with microcontrollers or programmable logic, while the 3 V or 5 V supply operation accommodates both industrial and embedded measurement equipment.
Typical applications include weighing systems, pressure and force measurement, temperature instrumentation, industrial process-control equipment, laboratory instruments, and portable measurement devices. The AD7714YRZ is particularly useful when a transducer produces a small differential signal and the system requires high resolution, low noise, and accurate offset correction rather than rapid sampling.
The primary design consideration is reference and input-noise management. Differential input and reference routing should be symmetric, the analog ground and supply planes should be kept clean, and filtering or shielding should be used where transducer cables introduce noise. Firmware should also account for the settling behavior introduced by the digital filter and use the converter’s calibration capability before demanding final accuracy.
直接替换替代料: AD7714YRZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD7714YRZ (相同外形与封装尺寸) ——差异在于 Package, Reference Input, Resolution, Supply Voltage Range.
AD7714YR
✅ 直接替换联系询价
查看数据手册 →AD7714YRZ 最大额定值与电气特性
| ADC Type | 24-bit sigma-delta ADC |
| 分辨率 | 24 bits |
| No Missing Codes | 24 bits |
| Supply Voltage Range | 3 V to 5 V |
| 电源电流 | 500 µA |
| Analog Input Configuration | 3 differential inputs or 5 pseudo-differential inputs |
| Reference Input | 1 differential reference input |
| Typical Accuracy | ±0.0015% |
| RMS Input Noise | 140 nV |
| Conversion Architecture | Sigma-delta |
| Calibration | On-chip self-calibration |
| Zero-Scale Error Correction | On-chip self-calibration |
| Full-Scale Error Correction | On-chip self-calibration |
| Temperature-Drift Correction | Addressed by on-chip self-calibration |
| Digital Output | Serial digital word |
| 封装 | 24-SOIC |
| Package Pin Count | 24 pins |
| 安装类型 | Surface mount |
AD7714YRZ 24 pins 引脚配置指南
AD7714YRZ(24 pins 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD7714YRZ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD7714YRZ 适用于 6 应用s: Precision Weighing Systems, Pressure and Force Transducer Measurement, Industrial Process Control, Laboratory Instrumentation, Temperature and Resistance Measurement, Portable Environmental Monitoring.
Precision Weighing Systems
The AD7714YRZ fits load-cell and strain-gauge measurements where the useful signal is small, noisy, and measured at a low update rate. Its 24-bit no-missing-code conversion, 140 nV rms noise, and ±0.0015% typical accuracy provide high resolution and calibration control for commercial scales and laboratory balances. The three differential or five pseudo-differential input options permit multiple bridge channels without adding separate analog front ends. On-chip zero-scale, full-scale, and temperature-drift calibration helps stabilize results over time. Because the sigma-delta converter emphasizes precision rather than speed, system designers should wait for the required digital-filter settling interval before latching each result.
推荐
Pressure and Force Transducer Measurement
The AD7714YRZ is well suited to pressure, force, and displacement systems in which a resistive bridge produces a low-level differential signal. Differential inputs reject common-mode voltage, while 140 nV rms noise supports stable readings from compliant sensors. The device's integrated self-calibration corrects zero-scale and full-scale errors associated with offset, gain, and temperature drift, reducing recurring adjustment in deployed equipment. Its 500 µA operating current also supports compact industrial transmitters. Design the analog section around quiet reference routing, symmetric input traces, and a protective front end, and allow the digital filter to settle before declaring a new pressure or force value valid.
推荐
Industrial Process Control
The AD7714YRZ can digitize slow industrial process signals such as tank pressure, valve position, and temperature-derived analog levels. Its 3 V or 5 V operation supports embedded industrial controllers, while the serial interface limits wiring requirements compared with a parallel ADC. On-chip calibration improves consistency when the installation experiences temperature variation, and the differential input structure helps preserve signal integrity in electrically noisy environments. The converter is most appropriate for channels that change slowly enough for the digital filter to settle. Engineers should isolate the analog path from relays, motor drives, and switching power stages, and verify the allowable analog input and reference voltages in the official electrical-characteristics table.
推荐
Laboratory Instrumentation
The AD7714YRZ is appropriate for laboratory instruments that measure low-level voltages with high resolution rather than high throughput. Its 24-bit conversion resolution, 140 nV rms noise, differential reference, and on-chip calibration support precision measurement equipment, including programmable sources, reference monitors, and resistance-ratio measurements. The 24-SOIC package is compact enough for multi-channel instrument front ends, and operation from a single 3 V or 5 V rail simplifies low-power designs. Accurate results still depend on a low-noise reference, clean grounding, and proper settling-time control. For bench instruments, remove or stabilize external EMI sources and schedule self-calibration at defined intervals when long-term drift must be controlled.
推荐
Temperature and Resistance Measurement
The AD7714YRZ can measure thermocouple, RTD, thermistor, or resistive-sensor outputs when the front end converts the sensor into a suitable differential voltage. The 24-bit resolution and low 140 nV rms noise improve the usable resolution of small temperature-derived signals, while the differential reference allows ratiometric operation against a sensing element. On-chip calibration corrects offset and full-scale errors, which is useful in equipment exposed to ambient temperature changes. The sigma-delta filter rejects high-frequency noise but introduces a settling delay, so the measurement algorithm must account for that delay. Cold-junction compensation, linearization, and sensor-specific excitation should be implemented separately in the host or companion circuitry.
推荐
Portable Environmental Monitoring
The AD7714YRZ supports compact environmental and portable measurement systems that combine a low-power sensor with a microcontroller. Its 500 µA current consumption and single 3 V or 5 V operation reduce the energy burden of continuously monitoring pressure, gas-sensor analog outputs, or slow environmental changes. The converter handles analog conditioning and self-calibration locally, allowing the controller to focus on sampling, interpretation, and communications. A 24-SOIC package preserves board area while providing a serial interface that works naturally with embedded processors. Battery designs should still account for reference, sensor, and digital-interface current, use a clean reference arrangement, and synchronize readings with the converter's digital-filter settling behavior.
推荐
推荐产品汇总
工程参考数据: AD7714YRZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD7714YR |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | 24-SOIC | 24-SOIC |
| Resolution | 24 bits | 24 bits |
| ADC Architecture | Sigma-delta | Sigma-delta |
| Supply Voltage | 3 V to 5 V | 3 V to 5 V |
| Supply Current | 500 µA | 500 µA |
| Analog Input Configuration | 3 differential or 5 pseudo-differential inputs | 3 differential or 5 pseudo-differential inputs |
| Reference Input | Differential reference input | Differential reference input |
| Typical Accuracy | ±0.0015% | ±0.0015% |
| RMS Input Noise | 140 nV | 140 nV |
| Calibration | On-chip self-calibration | On-chip self-calibration |
关键差异点
- Integrated low-frequency signal conditioning (对比 AD7714YR)
- Low-noise precision conversion (对比 AD7714YR)
- Power-efficient embedded measurement (对比 AD7714YR)
设计说明
Route each differential analog input as a closely matched pair, and treat the differential reference pair with the same care. Keep the analog section away from switching nodes, relay contacts, high-current returns, and digital clock traces. A solid analog ground region with a controlled connection to the system ground is preferable to routing analog return current through digital paths. These practices minimize common-mode-to-differential conversion and preserve the benefit of the AD7714's differential input architecture.
Do not treat the 24-bit resolution label as an immediate 24-bit accuracy guarantee. Noise, reference quality, analog front-line errors, filtering, and settling all affect the usable result. Follow the manufacturer calibration sequence before a high-accuracy measurement and allow the digital filter to settle before reading the serial output. Also confirm the analog input and reference voltage limits in the official electrical-characteristics table before applying a sensor excitation level.
The 500 µA specification describes the converter's low-power operating class, but a complete channel also consumes power in the reference source, sensor excitation, interface logic, and protection network. Use local decoupling close to the supply and reference pins, and avoid routing converter reference current through a shared, resistive analog rail. In battery-powered equipment, calculate the average current from converter activity, filter rate, duty cycle, and peripheral loads rather than relying on the headline device current alone.
A sigma-delta ADC can reject substantial out-of-band noise, but it cannot recover information already corrupted by overload, clipping, poor grounding, or unstable references. Keep the differential signal within the input range with margin and verify the reference polarity and voltage before enabling conversions. If the transducer cable is long or the environment contains variable motor noise, add appropriate input protection and filtering and evaluate the complete signal chain against the required conversion rate.
合规信息
Compliance attributes were not explicitly stated in the available product information. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status from the manufacturer's current product documentation before qualification.