Analog Devices

AD7714YRZ - 24-Bit Sigma-Delta ADC | Analog Devices

N.º da peça: AD7714YRZ ✓ Ativo
3 V to 5 V Vdss 500 µA Id 24-SOIC Package
MOQ: 1 |

AD7714YRZ Visão geral

The Analog Devices AD7714YRZ is a 24-bit sigma-delta analog-to-digital converter for low-frequency measurement applications, operating from a single 3 V or 5 V supply and consuming 500 µA. The device accepts low-level transducer signals directly and converts them into a serial digital word with no missing codes. It is housed in a 24-SOIC package.

An analog front end such as the AD7714 integrates input signal conditioning, a sigma-delta modulator, digital filtering, calibration, and conversion logic. Within the ADC hierarchy, it is a low-frequency precision ADC that accepts differential or pseudo-differential sensor inputs and provides a serial digital output. This integration allows a measurement system to use a small, low-power signal chain without adding a separate instrumentation amplifier or external gain stage.

Key features include conversion resolution up to 24 bits with no missing codes, typical accuracy of ±0.0015%, and low rms input noise of 140 nV. On-chip self-calibration removes zero-scale and full-scale errors as well as the effects of temperature drift. The converter supports three differential analog inputs that can alternatively be configured as five pseudo-differential inputs, together with a differential reference input for systems requiring flexible channel selection or ratiometric measurement.

The sigma-delta architecture is suited to precision rather than high-speed conversion. Its digital filtering suppresses out-of-band noise and averages successive samples to produce a stable result from low-frequency transducer outputs. Self-calibration improves repeatability by correcting offset and gain-related errors internally. The serial interface reduces the number of PCB signal lines and supports integration with microcontrollers or programmable logic, while the 3 V or 5 V supply operation accommodates both industrial and embedded measurement equipment.

Typical applications include weighing systems, pressure and force measurement, temperature instrumentation, industrial process-control equipment, laboratory instruments, and portable measurement devices. The AD7714YRZ is particularly useful when a transducer produces a small differential signal and the system requires high resolution, low noise, and accurate offset correction rather than rapid sampling.

The primary design consideration is reference and input-noise management. Differential input and reference routing should be symmetric, the analog ground and supply planes should be kept clean, and filtering or shielding should be used where transducer cables introduce noise. Firmware should also account for the settling behavior introduced by the digital filter and use the converter’s calibration capability before demanding final accuracy.

Alternativas drop-in para AD7714YRZ — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com AD7714YRZ (mesmo formato e footprint) — diferindo em Package, Reference Input, Resolution, Supply Voltage Range.

Analog Devices
Package: 24-lead SOIC
Resolution: 24 bit
Comparar com AD7714YRZ →
Analog Devices
Reference Input: Differential reference input
Supply Voltage Range: 3 V/5 V
Comparar com AD7714YRZ →

AD7714YR

✅ Drop-In
Analog Devices
📦 24-SOIC
24 bit · Sigma-delta · 3 differential inputs or 5 pseudo-differential inputs · 3 V/5 V · 500 µA typical · Differential reference input · 3-wire serial interface · Programmable filter cutoff, input gain, channel selection, signal polarity, and calibration modes

Consulte o preço

Ver ficha técnica →

AD7714YRZ Classificações máximas e características elétricas

ADC Type 24-bit sigma-delta ADC
Resolução 24 bits
No Missing Codes 24 bits
Supply Voltage Range 3 V to 5 V
Corrente de alimentação 500 µA
Analog Input Configuration 3 differential inputs or 5 pseudo-differential inputs
Reference Input 1 differential reference input
Typical Accuracy ±0.0015%
RMS Input Noise 140 nV
Conversion Architecture Sigma-delta
Calibration On-chip self-calibration
Zero-Scale Error Correction On-chip self-calibration
Full-Scale Error Correction On-chip self-calibration
Temperature-Drift Correction Addressed by on-chip self-calibration
Digital Output Serial digital word
Encapsulamento 24-SOIC
Package Pin Count 24 pins
Tipo de montagem Surface mount

Guia de Configuração de Pinos do AD7714YRZ 24 pins

Configuração de pinos para AD7714YRZ (pacote 24 pins). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.

Diagrama de pinagem do pacote 24 pins para AD7714YRZ

Nenhum dado detalhado de pinagem disponível para AD7714YRZ.

Consulte a ficha técnica para a configuração completa dos pinos.

Aplicações típicas

AD7714YRZ é adequado para 6 aplicaçãos: Precision Weighing Systems, Pressure and Force Transducer Measurement, Industrial Process Control, Laboratory Instrumentation, Temperature and Resistance Measurement, Portable Environmental Monitoring.

⚖️

Precision Weighing Systems

The AD7714YRZ fits load-cell and strain-gauge measurements where the useful signal is small, noisy, and measured at a low update rate. Its 24-bit no-missing-code conversion, 140 nV rms noise, and ±0.0015% typical accuracy provide high resolution and calibration control for commercial scales and laboratory balances. The three differential or five pseudo-differential input options permit multiple bridge channels without adding separate analog front ends. On-chip zero-scale, full-scale, and temperature-drift calibration helps stabilize results over time. Because the sigma-delta converter emphasizes precision rather than speed, system designers should wait for the required digital-filter settling interval before latching each result.

🏭

Pressure and Force Transducer Measurement

The AD7714YRZ is well suited to pressure, force, and displacement systems in which a resistive bridge produces a low-level differential signal. Differential inputs reject common-mode voltage, while 140 nV rms noise supports stable readings from compliant sensors. The device's integrated self-calibration corrects zero-scale and full-scale errors associated with offset, gain, and temperature drift, reducing recurring adjustment in deployed equipment. Its 500 µA operating current also supports compact industrial transmitters. Design the analog section around quiet reference routing, symmetric input traces, and a protective front end, and allow the digital filter to settle before declaring a new pressure or force value valid.

🏭

Industrial Process Control

The AD7714YRZ can digitize slow industrial process signals such as tank pressure, valve position, and temperature-derived analog levels. Its 3 V or 5 V operation supports embedded industrial controllers, while the serial interface limits wiring requirements compared with a parallel ADC. On-chip calibration improves consistency when the installation experiences temperature variation, and the differential input structure helps preserve signal integrity in electrically noisy environments. The converter is most appropriate for channels that change slowly enough for the digital filter to settle. Engineers should isolate the analog path from relays, motor drives, and switching power stages, and verify the allowable analog input and reference voltages in the official electrical-characteristics table.

🔬

Laboratory Instrumentation

The AD7714YRZ is appropriate for laboratory instruments that measure low-level voltages with high resolution rather than high throughput. Its 24-bit conversion resolution, 140 nV rms noise, differential reference, and on-chip calibration support precision measurement equipment, including programmable sources, reference monitors, and resistance-ratio measurements. The 24-SOIC package is compact enough for multi-channel instrument front ends, and operation from a single 3 V or 5 V rail simplifies low-power designs. Accurate results still depend on a low-noise reference, clean grounding, and proper settling-time control. For bench instruments, remove or stabilize external EMI sources and schedule self-calibration at defined intervals when long-term drift must be controlled.

🌡️

Temperature and Resistance Measurement

The AD7714YRZ can measure thermocouple, RTD, thermistor, or resistive-sensor outputs when the front end converts the sensor into a suitable differential voltage. The 24-bit resolution and low 140 nV rms noise improve the usable resolution of small temperature-derived signals, while the differential reference allows ratiometric operation against a sensing element. On-chip calibration corrects offset and full-scale errors, which is useful in equipment exposed to ambient temperature changes. The sigma-delta filter rejects high-frequency noise but introduces a settling delay, so the measurement algorithm must account for that delay. Cold-junction compensation, linearization, and sensor-specific excitation should be implemented separately in the host or companion circuitry.

📱

Portable Environmental Monitoring

The AD7714YRZ supports compact environmental and portable measurement systems that combine a low-power sensor with a microcontroller. Its 500 µA current consumption and single 3 V or 5 V operation reduce the energy burden of continuously monitoring pressure, gas-sensor analog outputs, or slow environmental changes. The converter handles analog conditioning and self-calibration locally, allowing the controller to focus on sampling, interpretation, and communications. A 24-SOIC package preserves board area while providing a serial interface that works naturally with embedded processors. Battery designs should still account for reference, sensor, and digital-interface current, use a clean reference arrangement, and synchronize readings with the converter's digital-filter settling behavior.

What is the AD7714YRZ?
The AD7714YRZ is a 24-bit sigma-delta analog-to-digital converter integrated with low-frequency signal-conditioning functions. According to the Analog Devices AD7714 data sheet, it accepts low-level transducer signals, supports 3 differential or 5 pseudo-differential inputs, operates from 3 V or 5 V, and consumes 500 µA. It is packaged in a 24-SOIC and produces a serial digital conversion result.
What are the key specifications of AD7714YRZ that engineers should know?
The AD7714YRZ provides up to 24-bit resolution with no missing codes, ±0.0015% typical accuracy, and 140 nV rms noise. It operates from a single 3 V or 5 V supply at 500 µA and accepts three differential or five pseudo-differential analog inputs. The Analog Devices data sheet also identifies on-chip self-calibration, differential reference input, digital filtering, and serial output as central device features.
Where can I download the AD7714YRZ datasheet PDF?
The official AD7714YRZ datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/AD7714.pdf. The document provides the device description, electrical characteristics, pin information, operating details, and application information for the AD7714 family. Use the manufacturer data sheet as the controlling reference for supply limits, pin functions, timing, and calibration behavior.
Where can I find the AD7714YRZ pinout?
The AD7714YRZ pinout is shown in the pin-description section of the official Analog Devices AD7714 data sheet. The component uses a 24-SOIC package with 24 leads, and the exposed lead assignments identify the analog inputs, differential reference, digital interface, supplies, and control functions. Assign PCB nets directly from that pin-description table rather than inferring connections from an image or an unverified board layout.
Is the AD7714YRZ suitable for low-frequency transducer measurement?
Yes, the AD7714YRZ is specifically suited to low-frequency measurement systems that use resistive bridges, strain gauges, pressure sensors, or other small-signal transducers. Its 24-bit conversion resolution, 140 nV rms noise, differential input arrangement, and on-chip self-calibration improve the quality of measurements taken near the transducer. The main limitation is that its sigma-delta architecture prioritizes resolution and noise performance over rapid conversion.
What is the difference between AD7714YRZ and AD7714YR?
The AD7714YRZ and AD7714YR share the same 24-bit sigma-delta conversion architecture, pinout, and package according to the available cross-reference information. Both accept low-level transducer signals and include on-chip self-calibration. The two MPNs differ in ordering and temperature-grade suffix details, so engineers should confirm the exact ordering code, operating-temperature grade, and qualification requirements before treating one as a substitute.
When should I choose the AD7714YRZ over another 24-bit ADC?
Choose the AD7714YRZ when the design needs a low-frequency precision measurement, a 3 V or 5 V supply, a low 500 µA consumption, and direct support for differential or pseudo-differential transducer inputs. Its integrated self-calibration is valuable when offset, full-scale, and temperature-drift errors must be reduced. Choose a different ADC when the application requires substantially faster conversion, a different package, or an interface not provided by this device.
Can AD7714YRZ replace AD7714YR on an existing PCB?
The AD7714YR can function as a pin-compatible alternative to the AD7714YRZ because the cross-reference information identifies the same core 24-bit sigma-delta architecture, pinout, and package. A production substitution should still undergo manufacturer review of ordering codes, temperature range, calibration behavior, electrical limits, and qualification. Do not release the change solely from the package name; compare the full ordering tables.
What is the best drop-in replacement for AD7714YRZ?
The best verified drop-in candidate identified for the AD7714YRZ is the AD7714YR, which shares the same 24-bit sigma-delta ADC architecture, pinout, and package. No five-part set of pin-to-pin alternatives can be substantiated without introducing package or reel-code variants. Before replacing the part, verify the exact orderable suffix, temperature grade, supply limits, pin functions, and calibration requirements against the Analog Devices documentation.
Is there a cross-brand pin-compatible equivalent for AD7714YRZ?
No cross-brand, pin-to-pin-compatible equivalent for the AD7714YRZ is established by the available manufacturer and cross-reference information. The device combines a particular 24-SOIC pinout, differential input architecture, serial interface, and self-calibration behavior, so a converter with similar resolution alone is not a drop-in replacement. Request a documented pin-to-pin cross-reference from the original manufacturer before changing the component on a production design.
What can replace the AD7714YRZ?
The AD7714YR is the documented same-manufacturer replacement candidate for the AD7714YRZ because it shares the core 24-bit sigma-delta architecture, pinout, and package. Its ordering suffix differs, so check the manufacturer ordering table for temperature grade and delivery format. A functional ADC with a different pinout or interface may work after redesign, but it is not a direct replacement for an unchanged PCB.
How should the reference and analog inputs be routed on the AD7714YRZ?
Route differential analog inputs and the differential reference as symmetric pairs to minimize conversion of common-mode noise into differential error. Keep the analog section physically separated from switching nodes and digital return currents, and use a quiet ground and supply arrangement around the converter. The Analog Devices data sheet describes differential reference and analog-input capabilities; follow its recommended application circuitry for component values and filtering.
Does the AD7714YRZ require external calibration components?
The AD7714YRZ performs zero-scale and full-scale calibration on-chip, including correction associated with temperature drift. This reduces the need for external trim components for offset and gain calibration. Calibration sequencing and the settling interval still have to be managed by the host controller, so use the digital interface and timing information in the official data sheet when designing the measurement cycle.
Where can I buy AD7714YRZ and check current stock?
Current availability, order quantity, and lead time for the AD7714YRZ should be requested through the Request a Quote form on this page. The form allows the exact 24-SOIC ordering code, delivery format, and required quantity to be checked without relying on stale catalog records. Submit the target quantity and production schedule so the supply response reflects the correct package variant.
What is the price of AD7714YRZ?
The current commercial price and quantity breaks for the AD7714YRZ are generated by the Request a Quote form on this page. That request should identify the exact AD7714YRZ ordering code, 24-SOIC package, delivery quantity, and required shipment date. Using the form ensures the quotation reflects current supply conditions rather than a historical unit-price record.
What is the lead time and is AD7714YRZ in stock?
The current lead time and stock position for the AD7714YRZ should be confirmed through the Request a Quote form on this page. Include the required quantity, delivery format, target date, and whether the order is for prototype evaluation or production. The manufacturer product page lists the AD7714 family as production CMOS, while the package-specific procurement record determines current allocation for AD7714YRZ.

Dados de referência de engenharia para AD7714YRZ — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the AD7714YRZ when a design requires a low-frequency, high-resolution measurement from a small differential transducer signal and needs integrated self-calibration. Its 24-bit no-missing-code performance, 140 nV rms noise, ±0.0015% typical accuracy, three differential or five pseudo-differential inputs, differential reference, and 500 µA operating current are particularly useful for weighing, pressure, temperature, and process-control equipment. The AD7714YR is the verified same-package candidate when an ordering-code change is acceptable, but the exact suffix, temperature grade, and production suitability must be confirmed. Do not choose this family when high conversion throughput, an SPI-compatible interface, or a different package is required. A functional converter with similar resolution is not necessarily pin-compatible, so any proposed substitute should be checked against the official pin description, electrical limits, reference arrangement, and digital timing.

Comparação com alternativas

Parâmetro Este produto AD7714YR
Brand Analog Devices Analog Devices
Package 24-SOIC 24-SOIC
Resolution 24 bits 24 bits
ADC Architecture Sigma-delta Sigma-delta
Supply Voltage 3 V to 5 V 3 V to 5 V
Supply Current 500 µA 500 µA
Analog Input Configuration 3 differential or 5 pseudo-differential inputs 3 differential or 5 pseudo-differential inputs
Reference Input Differential reference input Differential reference input
Typical Accuracy ±0.0015% ±0.0015%
RMS Input Noise 140 nV 140 nV
Calibration On-chip self-calibration On-chip self-calibration

Principais diferenciais

  • Integrated low-frequency signal conditioning (vs AD7714YR)
  • Low-noise precision conversion (vs AD7714YR)
  • Power-efficient embedded measurement (vs AD7714YR)

Notas de projeto

Route each differential analog input as a closely matched pair, and treat the differential reference pair with the same care. Keep the analog section away from switching nodes, relay contacts, high-current returns, and digital clock traces. A solid analog ground region with a controlled connection to the system ground is preferable to routing analog return current through digital paths. These practices minimize common-mode-to-differential conversion and preserve the benefit of the AD7714's differential input architecture.

Do not treat the 24-bit resolution label as an immediate 24-bit accuracy guarantee. Noise, reference quality, analog front-line errors, filtering, and settling all affect the usable result. Follow the manufacturer calibration sequence before a high-accuracy measurement and allow the digital filter to settle before reading the serial output. Also confirm the analog input and reference voltage limits in the official electrical-characteristics table before applying a sensor excitation level.

The 500 µA specification describes the converter's low-power operating class, but a complete channel also consumes power in the reference source, sensor excitation, interface logic, and protection network. Use local decoupling close to the supply and reference pins, and avoid routing converter reference current through a shared, resistive analog rail. In battery-powered equipment, calculate the average current from converter activity, filter rate, duty cycle, and peripheral loads rather than relying on the headline device current alone.

A sigma-delta ADC can reject substantial out-of-band noise, but it cannot recover information already corrupted by overload, clipping, poor grounding, or unstable references. Keep the differential signal within the input range with margin and verify the reference polarity and voltage before enabling conversions. If the transducer cable is long or the environment contains variable motor noise, add appropriate input protection and filtering and evaluate the complete signal chain against the required conversion rate.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

Compliance attributes were not explicitly stated in the available product information. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status from the manufacturer's current product documentation before qualification.

Dados verificados em: 2026-11-26 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

AD7714YRZ datasheet AD7714YRZ datasheet pdf AD7714YRZ pinout AD7714YRZ specifications AD7714YRZ equivalent AD7714YRZ replacement AD7714YRZ cross reference AD7714YRZ vs AD7714YR AD7714YRZ 24-SOIC footprint Analog Devices AD7714YRZ AD7714YRZ 24-bit ADC AD7714YRZ 140 nV noise AD7714YRZ price AD7714YRZ stock AD7714YRZ transducer measurement

Componentes & termos relacionados

Analog Devices AD7714YRZ AD7714YR 24-bit ADC sigma-delta ADC analog front end low-frequency measurement differential input pseudo-differential input differential reference no missing codes 140 nV rms noise ±0.0015% accuracy on-chip self-calibration digital filter serial digital output 3 V supply 5 V supply 500 µA operating current 24-SOIC package surface mount transducer weighing system industrial process control precision measurement
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas