ADM213EARSZ - 5V 4/5 RS-232 Transceiver | Analog Devices
料号: ADM213EARSZ ✓ 量产中ADM213EARSZ 概述
An RS-232 transceiver is an interface IC that converts logic-level signals into RS-232 line levels and converts received line-level signals back into digital logic. The RS-232 transceiver category belongs to the broader interface IC hierarchy, where line drivers and receivers bridge modern digital electronics with older point-to-point serial equipment. The ADM2xx family is intended for EIA-232-E and V.28 communication interfaces, particularly where a single 5 V supply is available.
The ADM213E integrates four drivers and five receivers, giving it more receivers than drivers. It operates from one +5 V supply, supports data rates up to 200 kbps, and uses 0.1 µF charge-pump capacitors according to the manufacturer product information. Its shutdown and enable pins provide power-management flexibility, while two receiver outputs remain active in shutdown for selected monitoring applications.
The ADM213E family is positioned for harsh electrical environments and includes EMC-focused interface protection. The device converts CMOS/TTL-compatible logic to RS-232 levels and performs the inverse conversion on the receive side. Its mixed driver/receiver configuration supports equipment in which multiple status or handshake signals must be monitored but only a smaller number of channels require transmission.
Typical uses include industrial serial controllers, instrumentation equipment, point-to-point data links, and legacy peripheral interfaces. The five receiver channels are useful for reading multiple control or status lines, while four drivers cover common RS-232 transmit assignments. In a shutdown sequence, selected receive paths can continue monitoring the bus, reducing dependence on complete power removal.
PCB design should follow the manufacturer pin and capacitor-placement instructions because incorrect charge-pump capacitor connections can prevent correct operation. Keep RS-232 driver outputs away from sensitive low-level analog traces, provide an uninterrupted ground return, and avoid long unprotected branches that increase capacitive loading on the cable.
This page combines device specifications, source-backed commercial guidance, drop-in alternatives, comparison parameters, and practical PCB and power-management notes. It also identifies where pin-level and certification details require consultation of the current Analog Devices documentation before layout release.
直接替换替代料: ADM213EARSZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADM213EARSZ (相同外形与封装尺寸) ——差异在于 Package, Interface Standard, Product Type, Enable Control, Shutdown Control.
ADM213EARZ
✅ 直接替换联系询价
查看数据手册 →ADM213EARU
✅ 直接替换📋 参考替代料(不在目录中)
TRS213
✅ 直接替换📋 参考替代料(不在目录中)
ADM213EARSZ 规格参数
| Product Type | RS-232 / V.28 transceiver |
| 电源电压 | +5 V |
| Number of Drivers | 4 |
| Number of Receivers | 5 |
| 数据速率 | 200 kbps |
| Charge-Pump Capacitor Value | 0.1 µF |
| Transceiver Configuration | 4 drivers / 5 receivers |
| Shutdown Control | Yes |
| Enable Control | Yes |
| Receivers Active in Shutdown | 2 |
| Interface Standard | RS-232 / V.28 |
| 封装 | 28-pin SSOP |
| 安装类型 | Surface mount |
| RoHS 状态 | Compliant |
| EMC Compliance | EU EMC directive compliant |
ADM213EARSZ 28-pin ssop 引脚配置指南
ADM213EARSZ(28-pin ssop 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: ADM213EARSZ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADM213EARSZ 适用于 6 应用s: Industrial RS-232 Controllers, Point-to-Point Serial Links, Instrumentation and Test Equipment, Legacy Peripheral Interfaces, Power-Managed Serial Ports, Serial Port Expansion.
Industrial RS-232 Controllers
The ADM213EARSZ fits industrial controller boards that communicate with legacy equipment through a +5 V RS-232 port. Four drivers support common transmit channels, while five receivers allow additional command acknowledgments, interlocks, or status lines to be monitored. Operation up to 200 kbps supports control and diagnostic traffic rather than only very low-speed terminal links. Shutdown and enable control help the controller reduce power when the external bus is inactive, while two receivers can remain active for monitoring. The robust interface positioning and EMC compliance are useful in electrically demanding industrial environments, subject to normal signal-integrity and ESD layout practices.
推荐
Point-to-Point Serial Links
A point-to-point link can use the ADM213EARSZ when both endpoints require a single +5 V interface rather than a separate ±12 V supply. Its four drivers and five receivers provide enough channels for data, handshake, and status signaling, and the 200 kbps maximum rate is suitable for command and control traffic. The internally managed charge-pump arrangement simplifies the power-supply requirement compared with discrete RS-232 designs. Enable and shutdown inputs permit the link to enter a controlled low-power state. Cable routing and grounding remain important because the transceiver solves logic interfacing, not the transmission loss, capacitance, or protection requirements of the external cable.
推荐
Instrumentation and Test Equipment
The ADM213EARSZ is appropriate for test and measurement equipment that retains RS-232 for instrument control and legacy peripheral communication. The +5 V operating supply integrates naturally with contemporary control logic, while the 200 kbps rate supports short command and response exchanges. Five receiver inputs can collect equipment-ready, interlock, or fault signals alongside four transmitted channels. Selectively active receivers in shutdown permit important remote status lines to remain observable. Designers should still isolate external cables appropriately and follow the manufacturer pin and capacitor-placement instructions to maintain deterministic interface behavior.
推荐
Legacy Peripheral Interfaces
The ADM213EARSZ bridges modern CMOS logic and legacy RS-232 peripherals without requiring a separate 12 V interface supply. This is useful in service equipment, configuration tools, and adapters that must communicate with older printers, scanners, or test fixtures. Four drivers cover the typical data and control transmissions, while the extra receiver supports bus monitoring or a second handshake signal. The 200 kbps capability accommodates moderate-rate configuration traffic. The interface should be placed near the connector, with a low-impedance ground path and appropriately routed protection, because cable transients can propagate through the transceiver regardless of its internal logic functionality.
推荐
Power-Managed Serial Ports
The ADM213EARSZ suits power-managed serial ports where a system needs to disable most interface functions without losing access to selected status signals. Its shutdown control reduces activity in unused transceiver sections, and the enable input supports controlled operating-state transitions. Two receiver paths remain active during shutdown, enabling a host to monitor a remote system or detect a persistent fault condition. This arrangement can simplify supervisory logic compared with powering an entire RS-232 transceiver continuously. The exact active channels and control polarity must be implemented from the manufacturer pin table, and supply sequencing should prevent uncontrolled signal states at the external connector.
推荐
Serial Port Expansion
The ADM213EARSZ can expand a controller's available RS-232 channels when one transceiver does not provide enough driver and receiver paths. Four drivers and five receivers allow a system builder to combine data, handshake, and peripheral-status functions in one 28-pin SSOP device. The 200 kbps limit is suitable for command-oriented links and does not require a high-speed differential interface. Its +5 V operation helps simplify power planning in embedded control boards. Board designers should allocate connector-side protection and maintain short return paths because adding more logical channels does not eliminate cable charging, ground-loop, or transient-voltage constraints.
推荐
推荐产品汇总
工程参考数据: ADM213EARSZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADM213EARZ | ADM213EARU | TRS213 |
|---|---|---|---|---|
| Package | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Product Type | RS-232 / V.28 transceiver | RS-232 / V.28 transceiver | RS-232 / V.28 transceiver | RS-232 transceiver |
| Shutdown and Enable Control | Shutdown and enable pins | Shutdown and enable pins | Shutdown and enable pins | Shutdown and enable pins |
关键差异点
- More receive channels than the ADM213 family requires for basic bidirectional links (对比 TRS213)
- Selectively active monitoring during shutdown (对比 ADM213EARU)
- Single +5 V operation with integrated charge-pump support (对比 ADM213EARZ)
设计说明
Place the two 0.1 µF charge-pump capacitors directly between their specified pins and keep the associated traces short. Use the Analog Devices pin-description table as the authoritative assignment map. Maintain a continuous ground reference beneath the SSOP where practical, and route the RS-232 outputs away from clock, precision analog, and high-impedance sensing traces to reduce capacitive and inductive coupling.
Decouple the +5 V supply close to the device with the capacitance recommended by the manufacturer and follow the exact component values and placement shown in the datasheet application circuit. Treat enable and shutdown as sequencing controls rather than ordinary high-speed signals. Ensure that externally driven receiver outputs remain meaningful when the main transceiver section enters shutdown, particularly for supervisory fault-detection functions.
Do not treat ADM213EARZ, ADM213EARU, or TRS213 as an automatic substitution solely because the descriptions mention similar RS-232 functions. Confirm the 28-pin SSOP footprint, exposed-pin mapping, charge-pump connections, shutdown behavior, and receiver count against the specific ordering code. The ADM211EAR family should not be used as a drop-in substitute because comparison information specifically notes different pin functions and external capacitor requirements.
Place the transceiver near the external connector to minimize the distance traveled by high-voltage RS-232 driver signals. Use a direct chassis or board-ground return path rather than routing return current through sensitive signal traces. Provide suitable connector-side transient protection for exposed cables, and keep protection components close to the entry point so surge energy is not carried across the logic section of the board.
合规信息
Cross-reference information identifies the ADM213EARSZ as the RoHS-compliant, lead-free package variant. Analog Devices states that the ADM213E family complies with the EU EMC directive. REACH, AEC-Q100, halogen-free, and conflict-minerals status were not established by the manufacturer information available for this page.