ADM234LAQ 5V RS-232 Driver/Receiver | Analog Devices
料号: ADM234LAQ ✓ 量产中ADM234LAQ 概述
An RS-232 interface IC is a signal-conditioning device that converts logic-level digital signals into RS-232-compatible levels and converts incoming RS-232 signals back into CMOS logic levels. The RS-232 standard is widely used for point-to-point serial links in industrial equipment, test systems, and legacy computer peripherals. The ADM234LAQ belongs to the interface-IC hierarchy, where transceivers combine drivers, receivers, and the voltage-conversion functions required by the RS-232 electrical specification.
The ADM234LAQ operates from a single 5 V supply and includes on-board DC-DC converters that generate the negative voltage needed by an RS-232 line driver. The on-board converters reduce external power-supply complexity while allowing the device to meet RS-232 output-swing requirements from a 5 V source. Its CMOS implementation supports low-power operation and includes a shutdown function for systems where the interface must be disabled during inactive periods.
The device supports data rates up to 120 kB/s, making it appropriate for standard RS-232 links rather than high-speed differential protocols. Its receiver section is designed to reject noise and withstand the voltage range commonly encountered on RS-232 connections. The integrated four-driver and four-receiver organization supports multiple serial ports or separate control and data channels in one package.
Typical applications include industrial PLC and sensor interfaces, laboratory measurement equipment, barcode and scanner connections, service-console links, and embedded control boards. The single 5 V architecture is particularly useful when the host system does not provide a negative analog rail. The shutdown input can reduce system power when a port is not communicating, while the receiver remains active during shutdown according to the device features described by the manufacturer.
Designers should pay close attention to line-driver load, cable length, grounding, and logic-level compatibility. The RS-232 interface is point-to-point, and cable capacitance or excessive loading can reduce the usable data rate. Place the device close to the connector when practical, provide a low-impedance ground connection, and verify that the host UART voltage levels match the CMOS logic inputs and outputs. The integrated DC-DC architecture should be evaluated against the application’s noise requirements, particularly near sensitive analog measurement circuits.
直接替换替代料: ADM234LAQ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADM234LAQ (相同外形与封装尺寸) ——差异在于 Mounting Type.
该产品暂无直接替换替代料。
请求替代料ADM234LAQ 规格参数
| Product Type | RS-232 driver/receiver interface IC |
| 电源电压 | 5 V |
| Supply Voltage Range | 4.5 V to 5.5 V |
| 数据速率 | 120 kB/s |
| Number of Drivers | 4 |
| Number of Receivers | 4 |
| On-Board DC-DC Converter | Yes |
| Output Swing | 9 V |
| Low-Power Shutdown | Yes |
| Receiver Input Voltage | 30 V |
| RS-232 Standard Compliance | EIA-232-E and V.28 specifications |
| Logic Family | CMOS |
| 引脚数量 | 16 pins |
| 安装类型 | Surface mount or through-hole package depending on orderable variant |
ADM234LAQ standard 引脚配置指南
ADM234LAQ(standard 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: ADM234LAQ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADM234LAQ 适用于 6 应用s: Industrial Controller Serial Interface, Laboratory Measurement Equipment, Embedded Service and Configuration Port, Barcode and Scanner Connectivity, Instrumentation and Test System Backplane, Power and Process Monitoring Equipment.
Industrial Controller Serial Interface
The ADM234LAQ fits industrial controller and data-acquisition equipment that communicates through conventional RS-232 ports using a 5 V logic supply. Its four drivers and four receivers allow several serial channels to be consolidated into one 16-pin interface IC, while the 120 kB/s rating supports standard UART traffic. The integrated DC-DC converters generate the negative voltage required for RS-232 transmission, removing the need for a separate negative rail. For cable-connected equipment, use a solid ground reference, keep the interface close to the connector, and verify UART baud rate against cable length and capacitance.
推荐
Laboratory Measurement Equipment
The ADM234LAQ is useful in laboratory instruments that need a reliable RS-232 control and status connection from a 5 V powered circuit board. The single-supply architecture simplifies power planning, and the integrated DC-DC conversion avoids adding a separate negative analog supply. The 120 kB/s maximum data rate is appropriate for command and response traffic rather than continuous high-throughput transfers. Place the transceiver near the serial connector, terminate the cable ground reliably, and keep switching supplies away from sensitive analog sections to reduce coupling into measurement results.
推荐
Embedded Service and Configuration Port
The ADM234LAQ can provide a service or configuration port on embedded equipment where the main processor uses CMOS UART signals. Four receiver channels can monitor service commands, equipment status lines, or remote-control signals, while the driver channels support RS-232 connection to a host computer. The low-power shutdown feature helps reduce activity when the service port is not in use, while the manufacturer datasheet states that receivers remain active during shutdown. Confirm the host-side logic levels and connector pinout before finalizing the interface.
推荐
Barcode and Scanner Connectivity
The ADM234LAQ is appropriate for barcode scanners, identification terminals, and industrial peripherals that expose an RS-232 host port. A 5 V system can create the required positive and negative RS-232 levels without a separate charge-pump supply, and the 120 kB/s capability is more than sufficient for ordinary scanner data bursts. Place input and output protection close to the connector, maintain a low-resistance signal-ground path, and confirm that the connected scanner uses compatible logic polarity and connector assignments.
推荐
Instrumentation and Test System Backplane
The ADM234LAQ supports legacy test and instrumentation equipment that uses RS-232 for instrument control or service diagnostics. Four drivers and four receivers allow the instrument to connect several peripheral lines while sharing a compact 16-pin footprint. The integrated DC-DC converters simplify single-board instrument designs that provide only 5 V, and the 120 kB/s rate suits command-oriented protocols. Use shielded cable where required, maintain consistent ground references between connected equipment, and avoid routing the RS-232 traces beside high-current switching paths.
推荐
Power and Process Monitoring Equipment
The ADM234LAQ can connect monitoring equipment, service laptops, and remote diagnostic adapters through RS-232 links. The four receiver channels are useful for monitoring multiple discrete status inputs, while the driver channels provide bidirectional command and response paths. Because the ADM234LAQ uses a 5 V supply and generates the negative RS-232 voltage internally, it can fit compact monitoring boards with limited power-tree capacity. Review board grounding and cable routing carefully in systems containing switching regulators or high-current relays to prevent ground bounce from corrupting the serial link.
推荐
推荐产品汇总
工程参考数据: ADM234LAQ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADM232AARW | MAX234EPE+ |
|---|---|---|---|
| Product Type | 5 V powered CMOS RS-232 driver/receiver | RS-232 driver/receiver | RS-232 driver/receiver |
| Package | 16-pin package | PDIP-16 | PDIP-16 |
| Brand | Analog Devices | Analog Devices | Maxim Integrated |
关键差异点
- Single 5 V supply with integrated negative-voltage conversion (对比 ADM232AARW)
- Documented 120 kB/s operating rate (对比 MAX234EPE+)
- Four drivers and four receivers in one 16-pin interface (对比 MAX234EPE+)
设计说明
Place the ADM234LAQ close to the RS-232 connector and route driver and receiver traces as short as practical. Keep the connector ground and the device ground connected with a short, low-impedance return path. Long stubs can increase ringing and make cable capacitance more influential, particularly when the UART operates near the 120 kB/s device limit.
Decouple the 5 V supply locally with the capacitance and placement specified in the manufacturer datasheet. Place the decoupling capacitor close to the supply pins and keep the return path short. Because the device contains on-board DC-DC converters, verify that switching noise from the internal converter does not interfere with nearby sensitive analog or timing circuits.
Do not assume that any RS-232 interface IC is a drop-in replacement. Confirm the package outline, lead numbering, driver and receiver assignments, shutdown polarity, supply range, and logic thresholds. The ADM232AARW and MAX234EPE+ are documented functional alternatives, but the available comparison material identifies package differences that must be resolved before PCB substitution.
Keep the RS-232 connector ground, cable shield termination, and analog ground reference strategy consistent with the equipment design. Avoid routing the interface through areas containing high-current switch nodes, relays, or inductors. For long or unshielded cables, lower the baud rate and use the receiver’s tolerance to support reliable operation in electrically noisy environments.
合规信息
The manufacturer-related listing identifies EIA-232-E and V.28 specifications. RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status are marked unknown because those attributes are not explicitly stated for this MPN.