ADM3078EARZ - 3.3V 16Mbps RS-485 Transceiver | Analog Devices
料号: ADM3078EARZ ✓ 量产中ADM3078EARZ 概述
An RS-485 transceiver is the physical-layer interface between a controller and a balanced differential bus. It converts a single-ended logic signal into differential A and B outputs and reverses that process on receive, allowing common-mode noise to be rejected while data travels between industrial, instrumentation, and telecommunications equipment. The ADM3078E family supports both RS-485 half-duplex operation and RS-422 balanced communication arrangements.
Key features include ±15 kV human-body-model ESD protection on the bus pins, a 16 Mbps maximum signaling rate, and a low 1/8 unit-load receiver input impedance that permits multiple nodes on the same bus. The transceiver provides separate driver-enable and receiver-enable controls, allowing the bus driver to be disabled during reception or held in a controlled state. Fail-safe receiver behavior helps maintain a defined output when the bus is idle or a driver is unpowered.
The 8-lead SOIC package exposes the driver input, receiver output, driver-enable and receiver-enable pins, ground, supply, and the differential bus terminals. Its 3.3 V supply operation suits modern low-voltage control systems where the transceiver must coexist with 3.3 V processors, field programmable I/O, and low-power sensors.
Typical uses include industrial process monitoring, factory automation, building controls, security equipment, instrumentation, and data acquisition links. The 16 Mbps capability supports high-speed data transfer, while the 1/8 unit-load rating reduces the loading penalty when several receivers share a bus.
When laying out the bus, keep the differential route short and matched, connect the bus terminals to the transceiver pins with minimal stubs, and place any required bus termination at the two physical ends of the trunk. Route the pair away from switching power nodes and high-current return paths. This page also organizes package, application, drop-in alternative, and design information for faster component selection.
直接替换替代料: ADM3078EARZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADM3078EARZ (相同外形与封装尺寸) ——差异在于 Package, Supply Voltage, ESD Protection, Data Rate, Duplex Mode.
ADM3078EYRZ
✅ 直接替换联系询价
查看数据手册 →ADM3072EARZ
✅ 直接替换联系询价
查看数据手册 →MAX3078EESA+T
✅ 直接替换📋 参考替代料(不在目录中)
SN65HVD3082EDR
✅ 直接替换联系询价
查看数据手册 →MAX13487EESA+T
✅ 直接替换联系询价
查看数据手册 →ADM3065EBRMZ
✅ 直接替换联系询价
查看数据手册 →NCV8500
✅ 直接替换📋 参考替代料(不在目录中)
ADM3078EARZ 规格参数
| Product Type | Half-duplex RS-485/RS-422 transceiver |
| 电源电压 | 3.3 V |
| Maximum Data Rate | 16 Mbps |
| ESD Protection | ±15 kV |
| Receiver Load | 1/8 unit load |
| Driver Count | 1 |
| Receiver Count | 1 |
| Duplex Mode | Half-duplex |
| Standards | TIA/EIA RS-485 and TIA/EIA RS-422 |
| 封装 | 8-lead SOIC |
| 安装类型 | Surface mount |
| Logic Input Levels | 3.3 V compatible |
| ESD Test Model | Human Body Model |
| Supply Connection | Single 3.3 V supply |
| Bus Output | Differential A and B outputs |
| Driver Control | DE driver-enable input |
| Receiver Control | RE receiver-enable input |
ADM3078EARZ 引脚配置
| 引脚 1 | RO — Receiver output |
| 引脚 2 | RE — Receiver enable input, active low |
| 引脚 3 | DE — Driver enable input, active high |
| 引脚 4 | DI — Driver data input |
| 引脚 5 | GND — Ground |
| 引脚 6 | A — Noninverting differential bus output and receiver input |
| 引脚 7 | B — Inverting differential bus output and receiver input |
| 引脚 8 | VCC — 3.3 V power supply input |
典型应用
ADM3078EARZ 适用于 6 应用s: Industrial Process-Control Bus, Factory Automation and Sensor Hubs, Building and HVAC Control Networks, Security and Access-Control Equipment, Instrumentation and Data Acquisition, Telecommunications and Remote Terminal Links.
Industrial Process-Control Bus
The ADM3078EARZ fits controller-to-sensor links on industrial process-control buses where 3.3 V logic, differential signaling, and ESD-protected bus pins are valuable. The 1/8 unit-load receiver minimizes loading when several field devices share a trunk, while the 16 Mbps maximum rate supports short, high-speed control links. Install termination only at the physical ends of the bus, keep A and B routing symmetrical, and route the pair away from motor and relay switching nodes. The DE and RE inputs permit controlled half-duplex operation, allowing the controller to disable the driver during reception and avoid bus contention.
推荐
Factory Automation and Sensor Hubs
In factory automation, the ADM3078EARZ can connect a 3.3 V controller to remote sensors, motor controllers, and condition-monitoring modules over an RS-485 backbone. Its 1/8 unit-load input is useful when several nodes must share one bus without heavily loading the driver. The 16 Mbps capability allows the same transceiver family to cover fast control and monitoring traffic over properly bounded cable runs. Keep stubs short, use a daisy-chain topology, and place common-mode or surge-protection components at exposed connectors rather than increasing signal rates beyond the cabling budget.
推荐
Building and HVAC Control Networks
The ADM3078EARZ is appropriate for RS-485 links between HVAC controllers, room modules, dampers, and temperature sensors in building automation. The 3.3 V supply permits direct interfacing with modern embedded controllers, and the 1/8 unit-load receiver supports multiple low-power field nodes on one bus segment. Its differential A and B outputs reject common-mode noise better than single-ended signaling, which helps in installations containing relays and variable-speed motor equipment. Use shielded cable with a defined grounding strategy, terminate both ends of the trunk, and separate field-bus routing from power wiring.
推荐
Security and Access-Control Equipment
The ADM3078EARZ can carry control and status traffic between access-control panels, card readers, intercoms, and cameras in commercial security systems. Its ±15 kV bus-pin ESD rating adds protection for ports that connect to field wiring, while the 3.3 V operating supply reduces system power requirements. The 16 Mbps capability supports short links carrying data and diagnostic traffic, and the 1/8 unit-load receiver helps limit loading in multi-drop installations. For cable entry points, add appropriate surge and common-mode protection and keep protection devices outside the high-speed differential trace path.
推荐
Instrumentation and Data Acquisition
The ADM3078EARZ supports laboratory and industrial data-acquisition systems that distribute commands and collect measurements across RS-422 or RS-485 links. A 16 Mbps maximum data rate supports high-resolution acquisition systems over short cable distances, while the 1/8 unit-load receiver allows several instrument modules to share a bus. The device's differential signaling reduces susceptibility to the noise commonly found around analog measurement circuits. Maintain matched A and B trace geometry, use solid ground references, and follow the manufacturer's recommended bypass-capacitor placement to prevent switching noise from entering the measurement chain.
推荐
Telecommunications and Remote Terminal Links
The ADM3078EARZ can interface a 3.3 V terminal card with remote RS-422 equipment over short, high-speed balanced lines. Its ±15 kV ESD protection is useful where a transceiver connects to routed cable through a connector, and the 16 Mbps rate accommodates status, configuration, or monitoring traffic without requiring a separate high-speed line-driver family. Use point-to-point RS-422 wiring where full-duplex behavior is required, or configure the half-duplex interface carefully for RS-485. Check connector pinouts and cable shielding, and avoid long unterminated branches on high-speed differential links.
推荐
推荐产品汇总
工程参考数据: ADM3078EARZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADM3078EYRZ | ADM3072EARZ | MAX3078EESA+T | SN65HVD3082E | MAX13487E |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Maxim Integrated | Texas Instruments | Maxim Integrated |
| Package | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC | 8-lead NSOIC | 8-lead SOIC | 8-lead SOIC |
| Function | Half-duplex RS-485/RS-422 transceiver | Half-duplex RS-485/RS-422 transceiver | RS-485/RS-422 transceiver | Half-duplex RS-485/RS-422 transceiver | RS-485 transceiver | RS-485/RS-422 transceiver |
| Supply Voltage | 3.3 V | 3.3 V | 3.3 V class | 3.3 V | 3.3 V class | 3.3 V class |
| Driver and Receiver Count | 1 driver, 1 receiver | 1 driver, 1 receiver | 1 driver, 1 receiver | 1 driver, 1 receiver | 1 driver, 1 receiver | 1 driver, 1 receiver |
| Bus Standards | TIA/EIA RS-485 and RS-422 | TIA/EIA RS-485 and RS-422 | RS-485/RS-422 | RS-485/RS-422 | RS-485 | RS-485/RS-422 |
关键差异点
- High-speed operation combined with light receiver loading (对比 ADM3072EARZ)
- Direct 3.3 V RS-485/RS-422 transceiver with documented bus-pin ESD protection (对比 MAX3078EESA+T)
- Same-manufacturer sourcing within the ADM3078E family (对比 SN65HVD3082E)
设计说明
Route A and B as a closely coupled differential pair with consistent geometry and minimal vias. Keep the bus traces away from switching-power nodes, relays, and high-current return paths because the A and B outputs reject common-mode noise but cannot compensate for an unbalanced route. At exposed connectors, place ESD and surge-protection components close to the entry point while keeping their capacitance from unnecessarily degrading edge rates.
Do not assume that an 8-pin SOIC transceiver is automatically a functional drop-in. Verify DE and RE polarity, receiver-output logic, fail-safe thresholds, propagation delay, receiver unit loading, and maximum data rate against the original schematic. The ADM3078EARZ supports 16 Mbps, but cable loss, stub length, topology, and node loading still determine whether that rate can be maintained reliably in the installed system.
Place the transceiver close to the bus connector and keep the route from the connector to A and B short and symmetrical. Terminate the trunk at its two physical endpoints only; do not add termination at every node in a multidrop network. Maintain a continuous ground reference under the interface and connect it according to the manufacturer's reference layout, taking care that cable shields do not create unintended ground loops.
For long cables, reduce the data rate to match the available bandwidth and add protection at the connector rather than increasing termination capacitance. The 16 Mbps rating applies to the device and its specified test conditions, not to an arbitrary field cable. Use controlled impedance, avoid long branch stubs, and verify the installed link with an oscilloscope or protocol analyzer when commissioning a multi-node system.
合规信息
The ADM3078E is listed as a production device by Analog Devices. Explicit RoHS, REACH, halogen-free, and conflict-minerals declarations were not present in the retrieved product information and are therefore recorded as unknown.