MAX13487EESA+T - 5V RS-485/RS-422 Transceiver | Maxim Integrated
料号: MAX13487EESA+T ✓ 量产中| 数量 | 单价 | 小计 |
|---|---|---|
| 1 | $0 | $0.00 |
| 10 | $0 | $0.00 |
| 100 | $0 | $0.00 |
| 500 | $0 | $0.00 |
| 1,000 | $0 | $0.00 |
MAX13487EESA+T 概述
An RS-485/RS-422 transceiver is a differential interface IC that converts single-ended logic signals into differential bus signals, sitting within the interface IC hierarchy of serial communications semiconductors. Half-duplex RS-485 transceivers share one differential pair for both transmit and receive, so direction control is a key architectural decision. Traditional parts require a microcontroller GPIO to drive the DE/RE pins; the MAX13487E instead uses Maxim's AutoDirection architecture, which senses the driver input and enables the driver automatically.
Key features include true fail-safe receiver circuitry guaranteeing a logic-high receiver output when inputs are shorted, open, or idle, hot-swap capability that eliminates false transitions on the bus during power-up or live insertion, and ±15kV ESD protection on the transceiver pins. The /SHDN pin reduces supply current for low-power systems, and /DI, /RE and /SHDN pins are rated from -0.3V to +6V, allowing direct interfacing with 3.3V microcontrollers without level shifting.
Architecturally, the device integrates one driver and one receiver operating from a +5V supply, with receiver input being 1/8 unit load, permitting up to 256 transceivers on a shared bus (per Cosine reference to equivalent-class devices). AutoDirection removes firmware overhead and timing errors associated with GPIO direction switching in polled half-duplex protocols.
Typical applications include industrial fieldbus and Profiling nodes, building automation and HVAC controllers, motor/drive networks, battery-management stacks, and embedded metering where robust differential communication over long cables is required.
Design consideration: the hot-swap feature matters when nodes are inserted into a live backplane; for software-controlled designs a conventional DE/RE part may be preferred instead. Verify bus biasing resistors for idle-state fail-safe operation.
This page synthesizes distributor availability data, cross-reference findings, and practical design notes not found in the manufacturer datasheet alone.
直接替换替代料: MAX13487EESA+T ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: MAX13487EESA+T (相同外形与封装尺寸) ——差异在于 Package, Supply Voltage.
快速对比工具——选择替代料号进行并排对比:
MAX13488EESA+T
✅ 直接替换📋 参考替代料(不在目录中)
MAX13487EESA+
✅ 直接替换✓ 有现货
联系询价
查看数据手册 →COS13487EESA
✅ 直接替换📋 参考替代料(不在目录中)
MAX13487EESA+T 规格参数
| Product Type | Half-Duplex RS-485/RS-422 Transceiver |
| Direction Control | AutoDirection (automatic) |
| 电源电压 | +5 V |
| 数据速率 | 500 kbps |
| Drivers / Receivers | 1 / 1 |
| Duplex Mode | Half |
| ESD Protection | +/-15 kV (HBM) |
| Hot-Swap Capability | Yes |
| Fail-Safe Receiver | Yes (short, open, idle) |
| Logic Pin Voltage Range (/SHDN, /RE, /DI) | -0.3 V to +6 V |
| 封装 | 8-SOIC (0.154 in / 3.90 mm width), NSOIC |
| 安装类型 | Surface Mount |
| Receiver Input Impedance | 1/8 unit load (256 transceivers on bus) |
| Reel Packaging | Tape and Reel (+T suffix) |
MAX13487EESA+T 8-soic (0.154 in / 3.90 mm width), nsoic 引脚配置指南
MAX13487EESA+T(8-soic (0.154 in / 3.90 mm width), nsoic 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: MAX13487EESA+T.
请参阅 数据手册 以查看完整引脚配置。
典型应用
MAX13487EESA+T 适用于 6 应用s: Industrial Fieldbus and MODBUS RTU Networks, Building Automation and HVAC Controllers, Battery Management and Energy Storage Stacks, Motor Drives and Industrial Motion Control, Smart Metering and Utility Data Concentrators, Security, Access Control, and Surveillance Panels.
Industrial Fieldbus and MODBUS RTU Networks
The MAX13487EESA+T fits industrial RS-485 fieldbus nodes because its 500 kbps data rate comfortably covers MODBUS RTU (typically 9.6-115.2 kbps) with timing margin, and its +/-15kV ESD protection survives the electrically noisy factory floor. AutoDirection control removes the MCU GPIO and firmware timing that classic DE/RE transceivers require, eliminating direction-turnaround bugs in polled master/slave protocols. Placed between the MCU UART and the twisted-pair bus with 120-ohm termination and fail-safe biasing resistors, the hot-swap input structure prevents bus glitches when a node card is inserted into a live backplane. The 1/8-unit-load receiver permits dense multi-drop networks of up to the RS-485 node limit without overloading the driver.
推荐
Building Automation and HVAC Controllers
Building automation controllers, thermostats, and HVAC rooftop units commonly interconnect over RS-485 (BACnet MS/TP, MODBUS). The MAX13487EESA+T's +5V operation matches legacy 5V controller supplies, while its logic pins rated -0.3V to +6V allow direct hookup to a 3.3V microcontroller without a level shifter, saving BOM cost in mixed-voltage designs. AutoDirection control simplifies the firmware of thermostat-class MCUs where UART direction timing is error-prone. Its fail-safe receiver outputs a defined logic level when the bus is idle, open, or shorted, so an offline segment does not produce garbage bytes. The hot-swap capability protects the shared MS/TP bus during live service replacement of controllers, a routine event in occupied buildings.
推荐
Battery Management and Energy Storage Stacks
Daisy-chained BMS slave boards across battery modules use isolated or non-isolated RS-485 links to report cell voltages and temperatures. The MAX13487EESA+T suits these links with its 500 kbps data rate for fast full-stack polling and its +/-15kV ESD robustness against charge transients during module handling. The /SHDN pin allows the transceiver to be powered down between polling cycles, conserving housekeeping power in battery-backed nodes. AutoDirection means the low-power slave MCU need not dedicate a GPIO or precise timing to bus turnaround, reducing firmware complexity on small 8-bit controllers. Verify isolation strategy separately: this transceiver is non-isolated, so pair it with a digital isolator or isolated DC-DC where galvanic isolation is mandated.
推荐
Motor Drives and Industrial Motion Control
Variable-frequency drives, servo amplifiers, and motion controllers exchange setpoints and status over RS-485 in noisy environments near PWM-switched power stages. The MAX13487EESA+T's differential signalling rejects common-mode noise, and its fail-safe receiver keeps the UART idle-detector stable if the communications cable is disconnected during commissioning. Hot-swap capability prevents false start bits when the drive's communications card is hot-plugged in a live cabinet. At 500 kbps, cyclic polling of drive parameters completes quickly enough for most motion-coordination schemes that do not require real-time fieldbus performance. The +/-15kV ESD rating helps withstand discharge events during maintenance in dry industrial facilities.
推荐
Smart Metering and Utility Data Concentrators
Electricity, water, and heat meters frequently expose an RS-485 service port per metering standards. The MAX13487EESA+T fits meter mainboards thanks to its 5V supply heritage, compact SOIC-8 footprint on dense two-layer meter PCBs, and low external component count - typically only termination and fail-safe bias resistors around the bus pins. AutoDirection control is valuable in meter firmware where the UART direction pin is a frequent source of poll/response collisions during protocol upgrades. The 1/8-unit-load receiver input supports meter clusters wired in long multi-drop strings back to a data concentrator. Its +/-15kV ESD tolerance addresses handling-induced discharge during meter installation and field servicing.
推荐
Security, Access Control, and Surveillance Panels
Access-control panels, door controllers, and PTZ camera buses historically run RS-485 (e.g., Pelco-D style protocols) over long cable runs. The MAX13487EESA+T is well matched here: 500 kbps covers all common panel protocols, the differential receiver tolerates the long untwisted legacy cabling often found in retrofits, and fail-safe receiver operation prevents spurious characters when a camera or reader is unplugged. AutoDirection removes per-byte direction switching in half-duplex polled loops. The +/-15kV ESD protection is a practical benefit at outdoor camera drops subject to static discharge. The small SOIC-8 package suits compact reader and door-interface boards where PCB area is constrained.
推荐
推荐产品汇总
工程参考数据: MAX13487EESA+T ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | MAX13488EESA+T | MAX13487EESA+ | COS13487EESA |
|---|---|---|---|---|
| Package | SOIC-8 (NSOIC, 3.90 mm) | SOIC-8 (NSOIC, 3.90 mm) - same | SOIC-8 (NSOIC, 3.90 mm) - same | SOP-8 - same footprint |
| Brand | Analog Devices (Maxim Integrated) | Analog Devices (Maxim Integrated) | Analog Devices (Maxim Integrated) | Cosine |
| Direction Control | AutoDirection (automatic) | Conventional DE/RE (MCU GPIO) | AutoDirection (automatic) | AutoDirection (internal auto-sensing) |
| Data Rate | 500 kbps | 500 kbps | 500 kbps | 500 kbps |
| Supply Voltage | +5 V | +5 V | +5 V | 3.0 V to 5.5 V |
| ESD Protection | +/-15 kV HBM | +/-15 kV HBM | +/-15 kV HBM | +/-15 kV HBM |
关键差异点
- AutoDirection control removes the direction GPIO entirely (对比 MAX13488EESA+T)
- True drop-in second source availability (对比 COS13487EESA)
- Hot-swap live-insertion protection (对比 Generic DE/RE transceivers (e.g., THVD1550))
设计说明
Do not treat the MAX13487E like a DE/RE transceiver: there is no driver-enable pin to poll. If your firmware already manages direction timing via GPIO (common in legacy designs), the MAX13488E with conventional DE/RE control may integrate more cleanly. Also remember the bus side is 5V-referenced - only the /SHDN, /RE and /DI logic pins are 3.3V tolerant (rated -0.3V to +6V per the Analog Devices EngineerZone FAQ). Do not exceed 500 kbps; exceeding the rated data rate with long stubs causes bit errors that AutoDirection cannot correct.
Use the standard RS-485 network topology: 120-ohm termination resistors at both physical cable ends, and fail-safe bias resistors (typically 560 ohms to +5V and 560 ohms to GND at one node) so the receiver output is defined on an idle bus. Place 0.1uF supply decoupling directly at the VCC pin and route the differential pair A/B as a matched pair away from switching-node traces. The SOIC-8 land pattern allows straightforward second-sourcing with the COS13487EESA without layout change.
The transceiver operates from a +5V rail; verify decoupling and rail sequencing when the node shares supply with 3.3V logic. Use the /SHDN pin to cut supply current during idle periods in battery-backed nodes - this is the family's power-saving mechanism since there is no low-quiescent-current variant in this listing. Estimated: a 5V node with multiple transceivers plus terminations draws most of its current in the termination resistors (60 ohms across the bus corresponds to roughly 83 mA at 5V during active drive), so budget the supply for worst-case bus load, not just IC quiescent current.
合规信息
Compliance status was not stated in the provided web data. Verify RoHS/REACH status on the Analog Devices product page or certificate of conformance before ordering.