ADM3222ARWZ - 230kbps 3.3V RS-232 Transceiver | Analog Devices
料号: ADM3222ARWZ ✓ 量产中ADM3222ARWZ 概述
An RS-232 transceiver is a semiconductor interface that converts logic-level signals into RS-232 line levels and receives RS-232 signals back into logic-compatible levels. It belongs to the interface IC hierarchy, connecting UART, UART-over-USB, and embedded systems to legacy RS-232 equipment. The ADM3222ARWZ provides bidirectional conversion through two driver channels and two receiver channels.
Principal features include operation from a single 3.3 V supply, low-power shutdown circuitry, four external 0.1 µF charge-pump capacitors, and support for portable instrumentation. The manufacturer product page specifies data rates up to 230 kbps. One distributor specification listing also identifies a 3 V to 5.5 V supply range, allowing the interface to operate across common low-voltage systems.
The charge-pump voltage doubler and inverter generate the bipolar voltage required by RS-232 from one low-voltage supply. Four external capacitors stabilize these rails, while the receiver channels translate the remote line voltage into CMOS-compatible signals. The separate transmit and receive channels permit simultaneous full-duplex operation on two ports.
Typical uses include battery-powered portable instruments, industrial data-acquisition equipment, point-of-sale terminals, service interfaces, and embedded systems that must communicate with RS-232 equipment. The 18-lead SOIC package is suitable for compact surface-mounted assemblies requiring two RS-232 ports.
PCB design must reserve the four charge-pump capacitor connections and place the capacitors close to their associated pins. A solid ground plane, short return paths, and controlled routing of exposed RS-232 cable-side nets help reduce radiated emissions and susceptibility to external interference.
This page combines interface specifications, application guidance, pin-compatible family options, and design notes to support component selection, schematic review, PCB implementation, and sourcing decisions for the ADM3222ARWZ.
直接替换替代料: ADM3222ARWZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
ADM3222ARW
✅ 直接替换📋 参考替代料(不在目录中)
ADM3202ARWZ
✅ 直接替换联系询价
查看数据手册 →ADM3222ARWZ 规格参数
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Transceiver Configuration | 2/2 full-duplex RS-232 |
| Nominal Supply Voltage | 3.3 V |
| Supply Voltage Range | 3 V to 5.5 V |
| Maximum Data Rate | 230 kbps |
| Listed Feature Data Rate | 460 kbps |
| Interface Standard | EIA-232E |
| Interface Standard | CCITT V.28 |
| External Charge-Pump Capacitors | 4 x 0.1 µF |
| Power Supply Architecture | Single +3.3 V supply |
| Shutdown Function | Yes |
| 封装 | 18-SOIC, 7.50 mm wide |
| 安装类型 | Surface mount |
| Lead-Free Status | Lead-free |
ADM3222ARWZ 18-soic, 7.50 mm wide 引脚配置指南
ADM3222ARWZ(18-soic, 7.50 mm wide 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: ADM3222ARWZ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADM3222ARWZ 适用于 6 应用s: Portable Instrument Serial Interface, Industrial Data Acquisition, Point-of-Sale Terminal, Embedded UART-to-RS-232 Bridge, Network Equipment Maintenance Port, Medical and Laboratory Instrument Control.
Portable Instrument Serial Interface
The ADM3222ARWZ fits portable test and measurement instruments that expose a legacy RS-232 service port while operating from a 3.3 V battery-powered rail. Two drivers and two receivers provide full-duplex communication on two channels, while the single-supply charge-pump architecture removes the need for a separate negative voltage rail. Its manufacturer-listed data rate of up to 230 kbps supports service-console and instrument-control traffic. Low-power shutdown is particularly useful during inactive periods, although the system-level sleep budget must include UART activity and charge-pump capacitor behavior.
推荐
Industrial Data Acquisition
The ADM3222ARWZ can connect a 3.3 V controller to two full-duplex RS-232 channels in industrial data-acquisition equipment. The dual 2/2 channel arrangement allows command traffic and measurement data to be handled simultaneously, reducing the need for separate RS-232 interface devices. Operation from one low-voltage supply simplifies system power distribution, and the charge-pump capacitors can be placed close to the device pins for cleaner routing. Engineers should allow adequate RS-232 line protection and verify cable length, grounding, and baud-rate requirements in the target installation.
推荐
Point-of-Sale Terminal
Point-of-sale terminals and service consoles can use the ADM3222ARWZ to bridge modern 3.3 V logic and RS-232 peripherals. Two transmitters and two receivers support more than one legacy device, including a printer, scanner, or service interface. The single 3.3 V supply architecture is useful where negative rail generation would add board area, while the listed rate of up to 230 kbps is more than sufficient for common peripheral traffic. Shutdown control can reduce demand when the terminal is idle, but system firmware should assert the relevant control states only after reviewing the datasheet timing.
推荐
Embedded UART-to-RS-232 Bridge
The ADM3222ARWZ is suitable for an embedded UART-to-RS-232 bridge because it accepts logic-level signals and supplies the bipolar line levels required by RS-232 equipment. A single 3.3 V supply reduces the power-tree complexity of the bridge, while four external 0.1 µF capacitors support the integrated charge-pump function. The two-channel arrangement can serve two external ports with independent transmit and receive paths. Firmware must keep the UART baud rate within the interface capability, and PCB routing should keep high-voltage line-side nets away from sensitive logic and ground-return paths.
推荐
Network Equipment Maintenance Port
The ADM3222ARWZ can implement a maintenance or diagnostic RS-232 port on network equipment that otherwise uses 3.3 V electronics. Its small 18-SOIC footprint and dual-channel capability make it suitable for providing both a primary console and an auxiliary service connection. The manufacturer lists conformance to EIA-232E and CCITT V.28, supporting interoperability with conventional RS-232 equipment. Because maintenance connectors can be accessible from outside an enclosure, add the appropriate transient-voltage and surge protection required by the installation while keeping protection current away from the transceiver inputs.
推荐
Medical and Laboratory Instrument Control
The ADM3222ARWZ can support RS-232 control or service connections in laboratory and medical instruments that use 3.3 V embedded controllers. The dual-driver, dual-receiver arrangement enables full-duplex command links and reduces external interface-component count, while shutdown support can help conserve power between test cycles. The listed 230 kbps capability is appropriate for control traffic rather than high-volume bulk transfer. Confirm medical-system safety requirements separately, preserve appropriate isolation boundaries, and review the complete pin and timing information in the manufacturer datasheet before using this device in a safety-related pathway.
推荐
推荐产品汇总
工程参考数据: ADM3222ARWZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADM3222ARW | ADM3202ARWZ |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 18-SOIC (0.295, 7.50 mm width) | 18-SOIC (0.295, 7.50 mm width) | 18-SOIC (0.295, 7.50 mm width) |
| Driver and Receiver Count | 2 drivers and 2 receivers | 2 drivers and 2 receivers | 2 drivers and 2 receivers |
| Interface | Full-duplex RS-232 | Full-duplex RS-232 | Full-duplex RS-232 |
| Nominal Supply Voltage | 3.3 V | 3.3 V | 3.3 V |
| Shutdown Function | Yes | Yes | No; not identified for the ADM3202 family |
| Mounting Type | Surface mount | Surface mount | Surface mount |
关键差异点
- Adds controllable low-power shutdown to the basic low-power RS-232 transceiver family (对比 ADM3202ARWZ)
- Maintains the same two-channel, full-duplex RS-232 architecture within an 18-SOIC footprint (对比 ADM3202ARWZ)
- Uses a single low-voltage supply for RS-232 level generation (对比 ADM3222ARW)
设计说明
Place the four required 0.1 µF charge-pump capacitors close to their associated ADM3222ARWZ pins and keep their return paths short. Follow the pin-description and typical-layout sections of the Analog Devices ADM3222 datasheet when assigning the capacitor nets. Avoid inserting long traces or test pads between each capacitor and the device, because additional loop area can increase charge-pump noise and make radiated-emissions performance less predictable.
Keep RS-232 driver-output routing away from UART logic, crystal circuitry, sensitive analog inputs, and other low-level signal paths. The receiver outputs are logic-side signals, while the driver outputs connect to the cable-facing pins, so maintain clear separation between those groups. Use a continuous ground reference, minimize loop area, and place any approved line protection close to the connector so surge current does not flow through the transceiver area.
Decouple the 3.3 V supply near the ADM3222ARVZ power pins with the capacitance recommended by the manufacturer datasheet and maintain a low-impedance connection to the ground plane. Do not substitute the RS-232 charge-pump capacitors for local supply bypassing; they serve a different circuit function. Verify startup, shutdown, and supply sequencing behavior in firmware so the device is not driven by an undefined logic level during power transitions.
合规信息
A distributor specification listing identifies the ADM3222ARWZ as lead-free. RoHS, REACH, halogen-free, and conflict-minerals status were not established from the listed technical data.