ADS774KP - 12-Bit, 8.5us SAR ADC in 28-Pin PDIP | Texas Instruments
料号: ADS774KP ✓ 量产中ADS774KP 概述
An ADC is a mixed-signal integrated circuit that converts an analog voltage into a digital number for processing, measurement, or control. The ADS774 belongs to the successive-approximation ADC family, whose internal CDAC compares the sampled input against binary-weighted references during successive conversion cycles. Compared with flash and dual-slope architectures, this SAR approach combines compact implementation, microprocessor-compatible control, and fast acquisition for many industrial, instrumentation, and embedded measurement systems.
The principal operating characteristics are 12-bit resolution, one analog input, successive-approximation conversion, a maximum conversion time of 8.5 microseconds, single +5 V operation, and a 28-pin PDIP package. Internal sampling eliminates the external sample-and-hold circuitry required by many earlier converters. The integrated reference and clock also simplify system implementation compared with modular data-acquisition designs.
The manufacturer describes the ADS774 as a drop-in replacement for ADC574, ADC674, and ADC774 models in most applications. This compatibility stems from the microprocessor-compatible interface and the converter family’s established signal arrangement. Engineers should nevertheless verify the complete pin description, timing behavior, input range, output coding, reference requirements, and acquisition sequencing in the manufacturer datasheet before replacing an existing design.
Typical uses include industrial process measurement, laboratory instrumentation, digital panel meters, data-acquisition systems, and embedded control equipment where a sampled bipolar or unipolar analog signal must be converted for a microprocessor. The internal sampling architecture is especially useful when board area is constrained and an external sample-and-hold amplifier would otherwise be required.
The primary design consideration is to follow the manufacturer’s interface and timing diagram when connecting the converter to a microprocessor. Provide the required bypass and reference-decoupling capacitors close to their associated pins, and observe signal settling requirements before initiating conversion. Because the ADS774KP is a through-hole 28-pin package, its larger footprint must be included when planning board space and connector placement.
This product page organizes the known electrical characteristics, package details, interface documentation, and application guidance into one engineering reference. It also identifies the legacy converter families that can serve as migration targets while highlighting the parameters that must be checked before approving a board-level replacement.
直接替换替代料: ADS774KP ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
ADC574
✅ 直接替换📋 参考替代料(不在目录中)
ADC674
✅ 直接替换📋 参考替代料(不在目录中)
ADC774
✅ 直接替换📋 参考替代料(不在目录中)
ADS774KP 最大额定值与电气特性
| 分辨率 | 12 bit |
| Analog Input Count | 1 input |
| Conversion Architecture | Successive approximation (SAR) |
| Maximum Conversion Time | 8.5 us |
| 电源电压 | +5 V |
| Internal Sampling | Yes |
| Internal Reference | Yes |
| Internal Clock | Yes |
| 接口类型 | Microprocessor-compatible |
| Converter Technology | CMOS |
| Internal Sampling Array | Capacitor array (CDAC) |
| 封装 | 28-pin PDIP |
| 安装类型 | Through-hole |
| External Sample-and-Hold Requirement | Eliminated in most applications |
ADS774KP 28-pin pdip 引脚配置指南
ADS774KP(28-pin pdip 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: ADS774KP.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADS774KP 适用于 6 应用s: Industrial Process Measurement, Laboratory Instrumentation, Digital Panel Meter, Embedded Data-Acquisition System, Industrial Control Feedback, Legacy Test and Measurement Upgrade.
Industrial Process Measurement
The ADS774KP fits industrial process measurement when a controller or data logger must convert a conditioned analog signal into a 12-bit digital value. Its successive-approximation architecture provides an 8.5 microsecond maximum conversion time, while the single-input format suits one channel at a time. Internal sampling reduces the external sample-and-hold circuitry normally associated with older converter designs. Use the device behind op-amp signal conditioning when the process signal exceeds the converter input range, and follow the manufacturer reference and bypass-capacitor arrangements for stable measurements.
推荐
Laboratory Instrumentation
The ADS774KP is appropriate for laboratory measurement equipment that acquires slow or moderate-rate analog waveforms and transfers each result to a microprocessor. Its 12-bit resolution provides 4096 output codes, while the 8.5 microsecond maximum conversion time supports acquisition systems that do not require flash-converter throughput. Internal sampling, reference, and clock functions reduce board complexity compared with a modular converter design. The instrument designer should still apply suitable input protection, analog filtering, and grounded reference routing to preserve measurement repeatability.
推荐
Digital Panel Meter
A digital panel meter can use the ADS774KP to convert a conditioned sensor voltage into a value displayed by a digital controller. The one-input SAR architecture is efficient for measurements performed on a sampled basis, and its 8.5 microsecond maximum conversion time is well suited to typical panel-update rates. Internal sampling helps simplify the analog front end, while the microprocessor-compatible interface supports integration with display and keypad control electronics. Select input conditioning and filtering according to the sensor output range rather than connecting raw sensor voltages directly.
推荐
Embedded Data-Acquisition System
The ADS774KP supports embedded data-acquisition systems that periodically measure one analog input and send the converted result to a processor. Its 12-bit resolution, 8.5 microsecond maximum conversion time, and internal sampling architecture provide a practical combination of accuracy and implementation simplicity. A controller can initiate acquisition, read the digital output, and perform system scaling or calibration in firmware. Validate acquisition timing and input settling against the manufacturer timing diagram, especially when the sensor source has high output impedance or a rapidly changing signal.
推荐
Industrial Control Feedback
The ADS774KP can serve as the measurement element in a closed-loop industrial controller that monitors a pressure, temperature, or position transducer. The converter’s 12-bit result provides discrete feedback information, while the single +5 V supply and integrated sampling, reference, and clock functions support a compact analog-to-digital subsystem. Signal-conditioning circuitry must translate the sensor output into the ADC input range and protect the input from transients. Firmware should also include calibration and fault detection because converter resolution does not by itself determine the accuracy of the complete measurement chain.
推荐
Legacy Test and Measurement Upgrade
The ADS774KP is useful when modernizing a legacy test or measurement instrument built around ADC574, ADC674, or ADC774 interfaces. Texas Instruments identifies the ADS774 as a drop-in replacement for those models in most applications, making it a practical option when retaining the existing board architecture is important. The modern CMOS implementation adds internal sampling and supports single +5 V operation. Before replacement, compare every pin, the input range, conversion timing, output code, reference behavior, and acquisition control sequence against the original circuit.
推荐
推荐产品汇总
工程参考数据: ADS774KP ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADC574 | ADC674 | ADC774 |
|---|---|---|---|---|
| Manufacturer | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 28-pin PDIP | 28-pin PDIP | 28-pin PDIP | 28-pin PDIP |
| Internal Sampling | Yes | Legacy converter; comparison requires datasheet review | Legacy converter; comparison requires datasheet review | Legacy converter; comparison requires datasheet review |
| Microprocessor Interface | Integrated microprocessor-compatible interface | Microprocessor-compatible legacy family | Microprocessor-compatible legacy family | Microprocessor-compatible legacy family |
关键差异点
- Internal sampling reduces external converter complexity (对比 ADC574)
- Single-supply CMOS implementation (对比 ADC674)
- Fast maximum conversion interval (对比 ADC774)
设计说明
Follow the reference and bypass-capacitor arrangement in the manufacturer application circuit. Place the input and output capacitors close to their corresponding pins to minimize parasitic inductance and high-frequency supply noise. Keep the analog input trace short, use a continuous ground reference beneath the converter area, and route digital control and data lines away from the input node. The 28-pin PDIP outline requires additional board clearance compared with a surface-mount ADC.
Do not treat the statement that ADS774 replaces ADC574, ADC674, and ADC774 models as a blanket guarantee for every suffix. Compare pin names, input range, output coding, reference voltage, conversion timing, acquisition sequence, and supply limits before modifying a production board. Pay particular attention to polarity and conversion status because incorrect read timing can capture a previous conversion result.
Design the source impedance and acquisition network so the analog input settles within the ADS774KP acquisition interval. Use the manufacturer acquisition-time requirements when selecting series resistance, capacitor values, and sensor bandwidth. If the source can slew rapidly, place an appropriate low-pass filter before the input; excessive input capacitance can increase settling time, while excessive source impedance can degrade conversion accuracy.
The ADS774KP operates from a single +5 V supply. Decouple that supply at the device with the capacitance and placement specified in the manufacturer circuit, and account for the converter’s input current and digital-output activity when designing the supply budget. Although the ADS774 consumes less power than the legacy families it replaces, use the numerical limits from the datasheet for thermal and power calculations.
合规信息
No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was identified for ADS774KP. AEC-Q100 qualification is not indicated for this catalog listing.