ADS8507IDW - 16-Bit 40 kSPS SAR ADC | Texas Instruments
料号: ADS8507IDW ✓ 量产中ADS8507IDW 概述
An SAR ADC is a sampling data-conversion device that uses a capacitor-based internal DAC and successive comparison steps to convert an analog voltage into a digital code. The ADS8507 combines this architecture with sample-and-hold circuitry, clocking, reference, and data-interface functions. Within the broader data-converter hierarchy, it is an ADC, a data-converter IC, and a semiconductor designed for precision analog signal acquisition.
Principal features include 16-bit conversion resolution, a maximum sampling rate of 40 kSPS, a single input channel, an internal reference, and selectable parallel or serial communication. The internal reference reduces the number of external precision components needed in a measurement system, while the parallel interface supports direct connection to digital control logic. The serial interface can reduce pin count and wiring complexity in systems with limited board space.
Operationally, the converter samples its input at the start of a conversion and then performs successive approximation against its internal reference. Its single-ended input architecture simplifies system connection, although input range, source impedance, acquisition time, and filtering remain central to achieving the intended accuracy. Because the part combines an internal reference and configurable input ranges, applications should verify signal-conditioning limits against the manufacturer’s pin description and electrical-characteristics tables before finalizing the analog front end.
Typical uses include industrial process measurement, instrumentation, data acquisition, sensor-interface systems, and embedded control applications. The 40-kSPS rate is suitable for many slowly changing or moderate-bandwidth measurements rather than high-frequency waveform acquisition. A microcontroller or programmable logic controller can read results through either the parallel bus or the serial interface, depending on connector count, routing density, and throughput requirements.
A practical design consideration is input conditioning. Place the input filter and acquisition network close to the ADC pins, provide a clean 5 V supply, and decouple the analog and digital supply pins as shown in the manufacturer’s application guidance. Verify source settling against the acquisition time and the selected input range, especially when using sensors with high output impedance.
This page consolidates the ADS8507’s core architecture, interface choices, ordering information, and application guidance with engineering-focused comparisons and design notes. It also highlights the distinctions that matter when evaluating pin-compatible variants or planning a new analog measurement board.
直接替换替代料: ADS8507IDW ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADS8507IDW (相同外形与封装尺寸) ——差异在于 Number of Input Channels, Package, Sampling Rate, Architecture, Mounting Type.
ADS8507IDWR
✅ 直接替换📋 参考替代料(不在目录中)
ADS8507IBDW
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ADS8507IBDWR
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ADS8507IDW 最大额定值与电气特性
| 分辨率 | 16 bit |
| 采样率 | 40 kSPS |
| Architecture | Successive approximation register (SAR) |
| Number of Input Channels | 1 channel |
| Input Type | Single-ended |
| Analog Supply Voltage | 4.75 V to 5.25 V |
| Reference | Internal |
| Digital Interface | Parallel and serial |
| 封装 | 28-pin SOIC (DW) |
| 安装类型 | Surface mount |
| 工作温度 | -40 °C to +85 °C |
| Integrated Functions | Sample-and-hold, clock, reference, and data interface |
| Converter Type | Sampling analog-to-digital converter |
ADS8507IDW 28-pin soic (dw) 引脚配置指南
ADS8507IDW(28-pin soic (dw) 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: ADS8507IDW.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADS8507IDW 适用于 6 应用s: Industrial Process Measurement, Test and Measurement Instrumentation, Sensor Interface and Data Acquisition, Embedded Control Systems, Power and Energy Monitoring, Communication and Conditioning Equipment.
Industrial Process Measurement
The ADS8507IDW is appropriate for industrial process monitoring where a slowly changing sensor signal requires greater resolution than a coarse digital measurement. Its 16-bit conversion result provides 65,536 code levels, while the 40-kSPS conversion rate is more than adequate for temperature, pressure, level, and other process variables. Place the converter behind a protected, low-noise analog front end and use the internal reference to reduce external precision-component requirements. For long sensor wiring, add suitable filtering and isolation ahead of the ADC rather than routing noisy signals directly to the input pin.
推荐
Test and Measurement Instrumentation
The ADS8507IDW fits laboratory and portable instrumentation that acquires low-bandwidth analog measurements and transfers them to a controller. The 40-kSPS rate supports responsive meter updates without requiring a high-speed flash ADC, while 16-bit resolution preserves fine measurement detail. The parallel interface can simplify connection to a parallel processor or FPGA, whereas the serial interface reduces wiring on space-constrained handheld equipment. Preserve analog performance by using a quiet 5 V rail, local supply bypass capacitors, and a short, guarded input path with settling time appropriate to the source impedance.
推荐
Sensor Interface and Data Acquisition
The ADS8507IDW can digitize outputs from moderate-bandwidth sensors such as resistive bridges, temperature elements, pressure transducers, and position sensors. The single-ended input and internal reference simplify a basic acquisition channel, while selectable parallel or serial interfaces support different controller architectures. The sensor output must remain within the converter’s supported input range and settle before sampling. For high-impedance sensors, include an adequate acquisition network and account for leakage, settling, and capacitive loading; the 40-kSPS rate should not be confused with unlimited bandwidth for fast transient signals.
推荐
Embedded Control Systems
The ADS8507IDW can provide a dedicated analog measurement channel in an embedded control system that monitors pressure, current, position, or environmental conditions. Its 40-kSPS throughput is sufficient for most supervisory control loops, and the serial interface offers a compact connection to a microcontroller, while the parallel interface can reduce data-transfer latency where enough GPIO is available. The controller should configure the converter according to the manufacturer’s timing diagram and handle conversion-ready signaling correctly. Firmware should also validate channel range and detect out-of-conversion conditions through the status and output coding defined by the device.
推荐
Power and Energy Monitoring
The ADS8507IDW is suitable for acquiring scaled voltage or current signals in energy-monitoring equipment where 16-bit resolution helps preserve small changes in the measured quantity. The 40-kSPS rate supports power, voltage, and current monitoring in many non-oscilloscope applications. Place a suitable shunt or divider network at the input and ensure the scaled signal remains within the configured converter range. Because the SAR ADC samples the input, timing relative to the power waveform is important if fast transients must be captured. For steady-state RMS, average, or energy calculations, synchronize acquisition with the measurement algorithm and validate scaling calibration.
推荐
Communication and Conditioning Equipment
The ADS8507IDW can digitize control, monitor, or analog supervision signals in communication equipment and interface conditioning products. The internal reference and selectable bus reduce support circuitry, while the 28-pin SOIC package is compatible with conventional surface-mount assembly. Keep sensitive analog routing away from switching nodes and high-speed digital returns, and use a solid reference and supply plane beneath the device where practical. Interface timing must satisfy the converter’s acquisition and conversion requirements. The 40-kSPS rate is most appropriate for supervisory channels rather than waveform-quality sampling of high-bandwidth communications signals.
推荐
推荐产品汇总
工程参考数据: ADS8507IDW ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADS8507IDWR | ADS8507IBDW | ADS8507IBDWR |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 28-pin SOIC (DW) | 28-pin SOIC (DW) | 28-pin SOIC (DW) | 28-pin SOIC (DW) |
| Resolution | 16 bit | 16 bit | 16 bit | 16 bit |
| Maximum Sampling Rate | 40 kSPS | 40 kSPS | 40 kSPS | 40 kSPS |
| Architecture | SAR | SAR | SAR | SAR |
| Number of Input Channels | 1 channel | 1 channel | 1 channel | 1 channel |
| Input Type | Single-ended | Single-ended | Single-ended | Single-ended |
| Reference | Internal | Internal | Internal | Internal |
| Digital Interface | Parallel and serial | Parallel and serial | Parallel and serial | Parallel and serial |
| Supply Range | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V |
| Order-Suffix Distinction | IDW industrial-temperature tube or reel order option | IDWR tape-and-reel format | IBDW temperature-grade order option | IBDWR temperature-grade tape-and-reel format |
关键差异点
- Higher conversion resolution than a typical lower-resolution data logger (对比 ADS7807PB)
- Supports both wide parallel and serial data transfer (对比 ADS8517IBDWR)
- Direct tape-and-reel ordering option without changing the converter function (对比 ADS8507IDW)
设计说明
Route the analog input directly from the external signal-conditioning network to the ADS8507IDW input pin, with the shortest practical trace and a continuous ground reference. Place input filtering and protection close to the device so that protection-diode capacitance, leakage, and long traces do not degrade acquisition settling. Keep the input path away from switching-regulator nodes and high-speed digital return paths, particularly when resolving small sensor signals at 16-bit resolution.
Use a clean 5 V supply and the decoupling arrangement specified in the manufacturer application guidance. Connect analog and digital supply pins according to the datasheet, provide high-frequency bypass capacitance at the relevant pins, and minimize loop area between each bypass capacitor and its device pin. Check the power-supply noise spectrum against the required conversion accuracy; a nominally correct 5 V rail may still degrade the analog result if ripple or ground bounce is excessive.
Verify input settling before asserting the sample command, especially with a high-impedance sensor source. Include source resistance, capacitance, leakage, and the converter acquisition interval in the settling calculation. The 40-kSPS sampling rate does not remove the requirement for adequate acquisition time. If the signal changes rapidly during conversion, use the manufacturer’s timing diagrams and consider a dedicated track-and-hold stage when the required bandwidth or timing accuracy exceeds the integrated sampler’s capability.
Do not treat the parallel and serial interface options as simultaneously interchangeable without configuring the device correctly. Confirm interface mode, conversion clock source, conversion-ready indication, data alignment, and power-up state against the Texas Instruments ADS8507 datasheet. Also verify that the selected ADS8507 order suffix matches the required temperature grade and shipping format; a mechanically similar package does not remove the need to review ordering and marking information.
合规信息
Compliance declarations were not stated in the referenced product and distributor information. Verify current RoHS, REACH, lead-free, halogen-free, and conflict-minerals status with Texas Instruments for the exact ADS8507IDW orderable MPN.