AT90CAN64-16AUR - 16MHz 64KB CAN AVR MCU | Microchip
料号: AT90CAN64-16AUR ✓ 量产中AT90CAN64-16AUR 概述
An AVR microcontroller is an embedded-processing IC that combines a CPU core, Flash program memory, SRAM, timers, serial peripherals, interrupt handling, and general-purpose I/O in one device. The AT90CAN64 family adds a CAN controller to the AVR architecture, placing it between a general-purpose 8-bit microcontroller and a communications-focused embedded controller. Its 53 general-purpose I/O lines support digital interfaces, sensors, actuators, and human-machine interfaces.
Key features include Read-While-Write Flash operation, 2 KB EEPROM, 4 KB SRAM, 53 general-purpose I/O lines, 32 general-purpose working registers, a real-time counter, four flexible timer/counter blocks with compare modes and PWM, two USARTs, and a byte-oriented two-wire serial interface. The integrated CAN controller supports automotive and industrial communication designs where robust message-based networking is required.
The 16 MHz operating frequency gives the AVR core a practical balance between processing throughput, power consumption, and peripheral timing. AT90CAN64 devices execute AVR instructions with an architecture designed for efficient embedded control, while the dedicated timer and serial resources allow multiple communication and timing tasks to be handled without relying entirely on software polling. The CAN peripheral is particularly useful when several embedded nodes must exchange prioritized, framed messages over a shared network.
Typical applications include CAN-based automotive modules, industrial monitoring equipment, building and access-control systems, instrumentation, robotics controllers, and CAN-connected sensor or actuator nodes. The 64-TQFP package provides enough I/O and peripheral access for systems requiring more connectivity than a small 8- or 16-pin AVR device can offer, while remaining suitable for automated board assembly and compact embedded products.
Design consideration: confirm transceiver requirements, bus termination, crystal or clock configuration, programming access, and exposed-pin assignments against the manufacturer datasheet before layout. CAN bus signal integrity also depends on the external transceiver, protection network, wiring, and termination rather than on the microcontroller alone. This page combines manufacturer feature information, distributor references, package details, practical application guidance, and carefully qualified drop-in alternatives.
直接替换替代料: AT90CAN64-16AUR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AT90CAN64-16AUR (相同外形与封装尺寸) ——差异在于 Package, Product Type, Supply Voltage.
AT90CAN64-16MUR
✅ 直接替换联系询价
查看数据手册 →AT90CAN64-16AUR 最大额定值与电气特性
| Product Type | 8-bit AVR RISC microcontroller with CAN controller |
| 最大时钟频率 | 16 MHz |
| Flash Memory | 64 KB (64K x 8) |
| Program Memory | 64 KB |
| EEPROM Memory | 2 KB |
| SRAM | 4 KB |
| General-Purpose I/O Lines | 53 |
| General-Purpose Working Registers | 32 |
| CAN Controller | 1 CAN controller |
| Timer/Counters | 4 with compare modes and PWM |
| USART Interfaces | 2 |
| Two-Wire Serial Interface | 1 byte-oriented interface |
| Real-Time Counter | 1 |
| Flash Feature | In-System Programmable with Read-While-Write |
| 电源电压 | 3.3 V to 5 V |
| 封装 | 64-TQFP (14 x 14 mm) |
| 安装类型 | Surface Mount |
| Packaging | Tape and reel |
AT90CAN64-16AUR 64-tqfp (14 x 14 mm) 引脚配置指南
AT90CAN64-16AUR(64-tqfp (14 x 14 mm) 封装)的引脚配置。 该数字 IC 包含 GPIO、通信接口(UART、SPI、I2C)和电源引脚。请参阅制造商数据手册以了解复用引脚功能和配置选项。对嵌入式系统设计和 PCB 布局至关重要。
暂无详细引脚数据: AT90CAN64-16AUR.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AT90CAN64-16AUR 适用于 6 应用s: Automotive CAN Control Modules, Industrial Monitoring and Control, Robotics and Motion Control, Building and Access-Control Systems, CAN-Connected Instrumentation, Distributed Sensor and Actuator Networks.
Automotive CAN Control Modules
AT90CAN64-16AUR fits compact vehicle-control modules because it combines a 16 MHz AVR core with an integrated CAN controller, 53 general-purpose I/O lines, four timer/counter blocks, and two USARTs. It can manage switches, sensors, actuators, diagnostic inputs, and communication gateway tasks without requiring a separate CAN controller. The 64 KB Flash and 4 KB SRAM provide room for protocol handling and application logic, while the external transceiver supplies the physical bus interface. Automotive deployment still requires confirmation of the exact qualification and environmental ratings.
推荐
Industrial Monitoring and Control
The AT90CAN64-16AUR supports distributed industrial monitoring by handling sensor inputs, alarms, local actuator control, and CAN-node communication in one 64-TQFP device. Its four timer/counter blocks can support timing, pulse capture, compare, or PWM functions, while two USARTs and the byte-oriented two-wire interface provide additional channels for displays, data loggers, and configuration devices. At 16 MHz with 64 KB of Flash, the controller is appropriate for coordinated machines or production equipment where deterministic embedded logic and robust field-bus communication are both required.
推荐
Robotics and Motion Control
AT90CAN64-16AUR is suitable for robot controllers and distributed motion-control nodes because its four timer/counter blocks provide resources for timing, compare events, and PWM generation. The 53 I/O lines allow simultaneous connection of encoders, limit sensors, motor drivers, status indicators, and communication transceivers. A CAN network can coordinate multiple axes or subsystems while the AVR core executes control logic. Designers should allocate timer channels carefully, use suitable output drivers for motors, and include galvanic protection where the external CAN bus may be electrically noisy.
推荐
Building and Access-Control Systems
The AT90CAN64-16AUR can serve as a door controller, sensor aggregator, or building-network node because it combines CAN communications with extensive digital I/O. Inputs from access readers, presence sensors, and push buttons can be processed locally, while outputs can drive relays, indicator circuits, or lock mechanisms through suitable driver stages. Two USARTs support peripheral or service connections, and the two-wire interface simplifies configuration or sensor buses. A secure production design should add appropriate authentication, electrical isolation decisions, watchdog strategy, and safe-state output behavior.
推荐
CAN-Connected Instrumentation
AT90CAN64-16AUR fits laboratory and process instrumentation that must acquire local signals while reporting data over a CAN network. The 16 MHz core and 4 KB SRAM support protocol handling and short measurement-control tasks, while two USARTs can serve debug or external-instrument links. Four timer/counter resources assist with pulse-rate measurements, timing, or PWM generation, and 53 I/O lines support digital front-panel controls. The MCU still requires external analog front-end circuitry for non-digital sensors, along with calibration and isolation appropriate to the measurement environment.
推荐
Distributed Sensor and Actuator Networks
AT90CAN64-16AUR works well as a local node in a distributed sensor or actuator network because its CAN controller, 53 I/O lines, and serial peripherals provide multiple connection options. Each node can acquire digital sensor states, execute local thresholds, and publish status messages through a CAN transceiver, reducing the burden on a central controller. The 64 KB Flash supports more elaborate local protocols than the 32 KB AT90CAN32 member. Designers should account for bus termination, protection, grounding, startup synchronization, and deterministic message timing across the network.
推荐
推荐产品汇总
工程参考数据: AT90CAN64-16AUR ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AT90CAN64-16MUR |
|---|---|---|
| Brand | Microchip Technology | Microchip Technology |
| Package | 64-TQFP (14 x 14 mm) | 64-TQFP (14 x 14 mm) |
| Architecture | 8-bit AVR RISC | 8-bit AVR RISC |
| Maximum Clock Frequency | 16 MHz | 16 MHz |
| Flash Memory | 64 KB (64K x 8) | 64 KB |
| CAN Controller | 1 CAN controller | 1 CAN controller |
| General-Purpose I/O Lines | 53 | 53 |
关键差异点
- Integrated CAN controller with ample AVR resources (对比 ATMEGA64A-ANR)
- Larger memory configuration than the AT90CAN32 family member (对比 AT90CAN32-16AUR)
- Tape-and-reel ordering option (对比 AT90CAN64-16AU)
- Broad embedded peripheral set (对比 AT90CAN32-16AUR)
设计说明
Route the CAN controller interface from the AT90CAN64-16AUR to the external transceiver as a short, tightly matched differential-capable connection, even though the MCU pins themselves are digital. Keep the transceiver, protection components, and termination network close to the connector or bus interface. Separate noisy switching and relay-drive paths from sensitive clock and programming routes. Follow the pin-multiplexing table in the manufacturer datasheet because many peripheral functions share the same I/O pins.
Provide local decoupling at every supply pin using the capacitor values and placement directed by the manufacturer datasheet. The CAN transceiver is electrically outside the MCU but can influence the local rail through transient events, so place its protection and bypass components near the transceiver rather than relying on bulk capacitance near the controller. Validate startup behavior across 3.3 V and 5 V operating conditions and confirm that the selected external components preserve adequate rise time for the chosen clock configuration.
Do not substitute a non-CAN ATmega solely because it uses the same AVR family and has similar Flash memory. The AT90CAN64-16AUR allocation of CAN, timer, USART, and interrupt resources can differ from the ATMEGA64A family, requiring both pin reassignment and firmware changes. For a production replacement, verify the complete TQFP pin map, peripheral multiplexing, electrical limits, clock behavior, and firmware register definitions before releasing the board revision.
Treat the physical CAN network as a separate high-speed channel requiring twisted-pair routing, controlled impedance, correct termination at both ends, and protection appropriate to the installation environment. The MCU and transceiver should share a compatible ground reference, but isolation may be needed where the nodes can sit at different ground potentials. Decouple communication faults from the control logic by using bus-off recovery behavior, watchdog supervision, and defined fallback states for connected actuators.
合规信息
The product records do not explicitly establish the requested compliance statuses for the exact AT90CAN64-16AUR ordering code. Confirm RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations with the manufacturer for the released part before environmental or automotive qualification use.