DS90CR584MTDX - 65MHz FPD-Link LVDS Receiver | Texas Instruments
料号: DS90CR584MTDX ✗ 停产DS90CR584MTDX 概述
A flat-panel display link is a high-speed serial interface that transfers pixel data between a display controller and a panel timing controller. The DS90CR583 transmitter converts 28 CMOS/TTL input bits into four LVDS streams and transmits a phase-locked clock in parallel over a fifth LVDS link. The DS90CR584 provides the receiving side of that architecture, recovering 28 parallel CMOS/TTL bits from the differential data streams. LVDS is a low-voltage differential-signaling technology used to reduce common-mode noise and support reliable high-speed data transfer over a compact cable or PCB connection.
The principal device characteristics are a 65 MHz operating link rate, four LVDS receiver channels, 28 parallel CMOS/TTL outputs, a 4.5 V to 5.5 V supply range, and a 56-pin TSSOP package. Its four differential data inputs are intended to work with the four data lanes sent by the corresponding transmitter, while the separately transmitted clock supports recovery of the parallel data. The 24-bit color designation relates to the display data carried by the 28-bit parallel interface, which can accommodate color information and associated control bits.
The DS90CR583 and DS90CR584 form an LVDS 24-bit color Flat Panel Display Link operating at 65 MHz. This arrangement separates high-speed differential transmission from the parallel logic-side interface: the transmitter accepts parallel CMOS/TTL data, while the receiver returns differential lanes to parallel CMOS/TTL data. Because the receiver is specified for four data streams, board designers should treat lane routing, connector pin assignments, and clock synchronization as an integrated transmitter-receiver design rather than treating each IC independently.
Typical uses include flat-panel monitor and display-controller boards, industrial panel interfaces, and other systems that pair the receiver with a compatible DS90CR583-family transmitter. The interface can be useful when a cable connection is preferable to a wide parallel bus because the four differential data lanes reduce signal-count requirements while supporting deterministic clock forwarding. System qualification should include the complete cable, connector, receiver, transmitter, and display-timing chain.
Layout is especially important in this high-speed differential interface. Route each LVDS pair as a tightly coupled, impedance-controlled pair and keep the receiver and transmitter ground references properly connected. Avoid adding unnecessary stubs, test pads, or long branches to the differential nets. Decoupling and signal-return paths must also follow the layout guidance in the manufacturer datasheet, particularly around the clock and data inputs.
This page combines the device identity, electrical limits, package information, interface use cases, and lifecycle status for the DS90CR584MTDX. It also provides engineering guidance for display-link implementation, replacement assessment, sourcing through the Request a Quote form, and comparison with related interface devices. Because this exact orderable MPN is listed as obsolete, designers should verify availability and consider an approved redesign rather than assuming that every similar line-driver or LVDS receiver is electrically interchangeable.
直接替换替代料: DS90CR584MTDX ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: DS90CR584MTDX (相同外形与封装尺寸) ——差异在于 Protocol.
该产品暂无直接替换替代料。
请求替代料DS90CR584MTDX 规格参数
| Device Type | Receiver |
| Receiver Channel Count | 4 LVDS receivers |
| Parallel Output Width | 28 bits |
| Maximum Link Clock | 65 MHz |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Protocol | FPD-Link |
| Signal Standard | LVDS |
| Logic-Side Interface | CMOS/TTL |
| 封装 | 56-TSSOP |
| Package Width | 6.10 mm |
| Package Body Width | 0.240 inch |
| Terminal Count | 56 terminals |
| Terminal Form | Gull wing |
| 安装类型 | Surface mount |
| Temperature Grade | Commercial |
| Packaging Format | Tape and reel |
| 生命周期状态 | Obsolete |
| Manufacturer | Texas Instruments |
| Original Manufacturer | National Semiconductor |
DS90CR584MTDX 0.240 inch 引脚配置指南
DS90CR584MTDX(0.240 inch 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: DS90CR584MTDX.
请参阅 数据手册 以查看完整引脚配置。
典型应用
DS90CR584MTDX 适用于 6 应用s: Flat-Panel Monitor Receiver, Industrial Display Controller, Digital Signage Display Board, Medical Display Interface, Point-of-Sale Terminal Display, Legacy Monitor Repair.
Flat-Panel Monitor Receiver
The DS90CR584MTDX fits the display-side receiver position in a 65 MHz FPD-Link system because it converts four differential LVDS data lanes into 28 CMOS/TTL bits for the panel logic. It is used with a compatible DS90CR583-family transmitter, which supplies the phase-locked clock on a separate fifth LVDS link. The 4.5 V to 5.5 V receiver supply and 56-TSSOP package support compact display-controller layouts, although the obsolete lifecycle requires careful system qualification and supply planning.
推荐
Industrial Display Controller
An industrial display controller can use the DS90CR584MTDX when the panel interface follows the DS90CR583/DS90CR584 FPD-Link architecture. The receiver accepts four LVDS data streams and delivers 28 parallel CMOS/TTL outputs, while the transmitter forwards a phase-locked clock for synchronized data recovery. Its 65 MHz clock rating supports the legacy display-link rate, but cable length, connector geometry, grounding, and system timing must be verified for each factory-floor display installation.
推荐
Digital Signage Display Board
The DS90CR584MTDX is applicable to digital-signage display boards that retain the National Semiconductor FPD-Link receiver topology. Four LVDS inputs reduce the number of high-speed conductors crossing a display cable compared with a 28-bit parallel bus, while the companion transmitter carries a phase-locked clock over a separate link. The implementation must preserve the original 56-pin TSSOP pinout, 4.5 V to 5.5 V supply limits, and timing margins when adapting the interface to modern signage electronics.
推荐
Medical Display Interface
A medical display interface may retain the DS90CR584MTDX when its source electronics use the established DS90CR583/DS90CR584 signaling architecture. The receiver's 65 MHz operation, four LVDS data streams, and 28-bit CMOS/TTL output support the display timing required by the legacy flat-panel link. Because clinical equipment may impose additional safety, EMC, and lifecycle requirements, engineers should validate the entire interface rather than assuming that the obsolete receiver status is acceptable for new production.
推荐
Point-of-Sale Terminal Display
The DS90CR584MTDX can serve as the panel receiver in a point-of-sale terminal that communicates with a controller through the 65 MHz FPD-Link architecture. Differential LVDS data lanes are useful when reducing cable conductors while the separate clock link supports deterministic transfer of the 28-bit parallel payload. The design must include controlled-impedance routing, connector and cable qualification, and suitable receiver decoupling. The obsolete lifecycle makes future availability a major design consideration for new retail deployments.
推荐
Legacy Monitor Repair
The DS90CR584MTDX is directly relevant to repair and refurbishment of monitors that use the original 65 MHz DS90CR583/DS90CR584 display link. The exact suffix identifies a 56-TSSOP receiver in tape-and-reel packaging, allowing a technician to compare the installed device, pin orientation, supply range, and clock characteristics before replacement. For long-term maintenance, use the Request a Quote form to confirm exact-MPN availability and condition because the manufacturer lists the device as obsolete.
推荐
推荐产品汇总
工程参考数据: DS90CR584MTDX ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 |
|---|---|
| Package | 56-TSSOP |
| Brand | Texas Instruments |
| Device Type | Receiver |
| Receiver Channels | 4 LVDS receivers |
| Parallel Output Width | 28 bits |
| Maximum Link Clock | 65 MHz |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Protocol | FPD-Link |
| Logic Interface | CMOS/TTL |
| Lifecycle Status | Obsolete |
关键差异点
- Purpose-built receiver role in the legacy FPD-Link pair (对比 DS90CR583)
- Established 65 MHz flat-panel-link architecture (对比 DS90CR285MTDX)
- Defined 28-bit receiver interface (对比 DS90C383MTDX)
设计说明
Route the four LVDS data pairs as tightly coupled, impedance-controlled nets with a continuous reference plane. Keep the inputs short and avoid stubs, long test-point branches, or unnecessary layer transitions. The 65 MHz link clock does not by itself represent the slowest edge rate, so use the transmitter and receiver rise-time specifications when setting trace geometry and termination.
Treat the DS90CR583 transmitter, phase-locked clock link, DS90CR584MTDX receiver, connector, and cable as one signal path. Verify differential voltage, common-mode limits, propagation delay, clock-data alignment, and connector loss against the manufacturer datasheet. Validate the assembled board with representative cable lengths because reflections and loss can degrade margin even when the nominal link clock remains below 65 MHz.
Operate the receiver from a regulated supply within the specified 4.5 V to 5.5 V range. Place decoupling capacitors close to the supply and ground terminals, and provide a low-impedance return path beneath the device. Check the supply voltage at the IC under transmitter activity and panel-load transients; clock and data activity can produce supply disturbance that affects receiver margins.
Do not substitute the DS90CR583 transmitter for the DS90CR584MTDX receiver or assume that any 28-bit LVDS receiver is interchangeable. Confirm all 56 terminal assignments, the four data-pair mapping, the separately transmitted clock connection, supply pins, and ground pins from the family datasheet. The exact-MPN obsolete status also means that package marking and lot documentation should be checked during repair or replacement.
合规信息
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations were identified for the exact MPN. The device is a commercial-temperature-grade display interface IC, so AEC-Q100 is not applicable based on its stated temperature grade.