料号: ICL7135CPI-2 ✓ 量产中ICL7135CPI-2 概述
A BCD A/D converter converts an analog input voltage into a binary-coded decimal value intended for direct display decoding. The ICL7135 belongs to the dual-slope ADC family, a converter category valued for predictable accuracy, excellent rejection of periodic noise, and suitability for low-rate panel measurements. Its architecture supports high-impedance differential input measurement while providing separate multiplexed digit outputs for four-digit plus sign displays.
Key features include 4.5-digit resolution, ±1 count in 20,000 accuracy, and a 2.0000 V full-scale capability. Differential inputs allow the converter to measure the voltage between two sources rather than only one input referenced to ground. Nearly ideal differential linearity, true ratiometric operation, auto-zero, and auto-polarity reduce calibration requirements and simplify front-end design.
The converter combines an analog measurement section with a digital timing and output section. During dual-slope conversion, the converter integrates the unknown input for a fixed interval and then compares the resulting reference charge against a controlled counter. Differential linearity and noise rejection arise from this controlled integration process. Multiplexed BCD outputs reduce the number of package pins required to communicate the measurement to display drivers.
Typical applications include laboratory and bench-top meters, digital panel meters, weighing scales, process-monitoring equipment, temperature-measurement instruments, and laboratory power supplies. The high-impedance differential input is particularly useful when the source has limited drive capability or when measurement errors from common-mode voltage must be reduced.
When implementing the circuit, place input and reference-network components close to the converter and maintain clean, low-leakage analog routing around the high-impedance inputs. Select stable reference and integration capacitors with suitable dielectric characteristics, and verify the displayed zero and span behavior over the expected temperature range. The 28-pin PDIP footprint favors through-hole instrumentation designs rather than compact surface-mounted products.
This product page combines the official ICL7135 family information with a package-aware comparison, practical design guidance, and same-footprint replacement considerations for engineers maintaining legacy precision-meter platforms.
直接替换替代料: ICL7135CPI-2 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ICL7135CPI-2 (相同外形与封装尺寸) ——差异在于 Output Format, Package, Conversion Accuracy, Conversion Rate, Converter Type.
ICL7135CPI+
✅ 直接替换联系询价
查看数据手册 →ICL7135CPI+2
✅ 直接替换📋 参考替代料(不在目录中)
ICL7135CPIZ
✅ 直接替换联系询价
查看数据手册 →ICL7135CN
✅ 直接替换联系询价
查看数据手册 →TC835CPI
✅ 直接替换📋 参考替代料(不在目录中)
ICL7135CPI-2 最大额定值与电气特性
| 分辨率 | 4.5 digits |
| ADC Architecture | Dual-slope conversion |
| Full-Scale Voltage | 2.0000 V |
| Conversion Accuracy | ±1 count in 20,000 counts |
| Output Format | Multiplexed 4-digit BCD |
| Input Configuration | High-impedance differential input |
| Differential Linearity | Nearly ideal |
| Reference Type | Ratiometric |
| Zero Adjustment | Automatic zero |
| Polarity Detection | Automatic polarity |
| 封装 | 28-pin PDIP |
| 安装类型 | Through-hole |
ICL7135CPI-2 28-pin pdip 引脚配置指南
ICL7135CPI-2(28-pin pdip 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: ICL7135CPI-2.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ICL7135CPI-2 适用于 6 应用s: Digital Panel Meters, Laboratory Digital Meters, Weighing Scale Instrumentation, Temperature Measurement Systems, Process Monitoring Equipment, Precision Voltage Measurement.
Digital Panel Meters
The ICL7135CPI-2 is well suited to digital panel meters because its 4.5-digit resolution and multiplexed BCD outputs directly support a four-digit plus-sign display. The dual-slope architecture provides ±1 count in 20,000 accuracy according to the official Analog Devices product page, while automatic zeroing simplifies offset correction. In an instrument, the converter sits between the sensor front end and display drivers, with its high-impedance differential input reducing source-loading errors and its BCD outputs reducing the interface pin count.
推荐
Laboratory Digital Meters
The ICL7135CPI-2 can serve as the measurement engine in a laboratory digital meter requiring stable readings from resistive sensors, dividers, or low-current transducers. Its 4.5-digit resolution and 2.0000 V full-scale range provide a precise conversion core, while true ratiometric operation can cancel reference variation when the input and reference share a proportional supply path. The 28-pin PDIP footprint favors through-hole instrument construction and maintenance of older meter platforms.
推荐
Weighing Scale Instrumentation
A weighing scale benefits from the ICL7135CPI-2's differential input architecture and 4.5-digit measurement resolution. The load-cell signal can be amplified and referenced before entering the converter, while automatic zero helps suppress offset drift. The device's dual-slope measurement cycle is appropriate for relatively slow weight readings, and its multiplexed BCD output can feed a display driver without requiring a parallel binary bus. Component leakage and reference stability remain important because the input network operates at high impedance.
推荐
Temperature Measurement Systems
The ICL7135CPI-2 can be used in temperature-measurement instruments when a linearized sensor signal is presented to a differential analog front end. Its 4.5-digit resolution provides enough displayed precision for many RTD, thermocouple-amplifier, or thermistor-network systems, while automatic polarity supports positive and negative readings around a midpoint. The converter's low-rate dual-slope operation fits slowly changing process temperatures and helps reject periodic noise without requiring a high-speed successive-approximation ADC.
推荐
Process Monitoring Equipment
The ICL7135CPI-2 is appropriate for process-monitoring equipment that displays a measured pressure, flow, level, or voltage rather than processing samples at high speed. Differential inputs allow the instrument to reject common-mode voltage present on industrial sensor wiring, and the 4.5-digit BCD result can be read by a dedicated display driver. Its 28-pin PDIP package supports through-hole industrial instrument construction, although grounding, reference isolation, and protection from surge events must be handled by the surrounding circuit.
推荐
Precision Voltage Measurement
The ICL7135CPI-2 supports precision voltage measurement when its 2.0000 V full-scale range is matched to the conditioned input. A ratiometric arrangement can improve stability by deriving the reference and measurement path from a related source, while automatic zeroing reduces input offset. Because the converter is a 4.5-digit integrating ADC, it favors stable DC measurements rather than waveforms or rapidly changing signals. Layout must keep high-impedance input nodes short and guard against board leakage and contaminated insulation.
推荐
推荐产品汇总
工程参考数据: ICL7135CPI-2 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ICL7135CPI | ICL7135CPI+2 | ICL7135CPIZ | ICL7135CN | TC835CPI |
|---|---|---|---|---|---|---|
| Package | 28-PDIP | 28-PDIP | 28-PDIP | 28-PDIP | 28-PDIP | 28-PDIP |
| Brand | Maxim Integrated | Renesas Electronics | Analog Devices Inc./Maxim Integrated | Renesas Electronics | Analog Devices | Teledyne Technologies |
| Resolution | 4.5 digits | 4.5 digits | 4.5 digits | 4.5 digits | 4.5 digits | 4.5 digits |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
关键差异点
- Legacy-sourcing match for ICL7135CPI-2 assemblies (对比 ICL7135CPI)
- Direct manufacturer-family ordering option (对比 ICL7135CPI+2)
- Renesas 28-PDIP service alternative (对比 ICL7135CPIZ)
设计说明
Route the high-impedance differential inputs as short as possible and keep them away from the clock, multiplexed BCD outputs, switching-regulator wiring, and exposed connector fields. Place input and reference-network components close to the corresponding converter pins. Because leakage at the input node can create a measurement error, use clean PCB surfaces, suitable guarding, and conformal protection when the sensor cable is long or humidity is significant.
Do not substitute a 28-PDIP ICL7135 ordering code solely by package shape. Confirm the pin functions, supply requirements, conversion timing, reference polarity, display multiplexing sequence, temperature grade, and ceramic or plastic construction against the applicable manufacturer datasheet. The ICL7135CPI-2 designation is also represented under legacy sourcing organizations, so the exact ordering-code history and device marking should be checked before releasing a replacement to production.
Decouple each supply rail near the converter with the capacitance and ESR requirements stated in the manufacturer datasheet. Reference components and integration capacitors should be selected for stability over the complete operating temperature range, including temperature coefficient and dielectric-voltage considerations. If the measurement reference is shared with a sensor or display supply, verify that ratiometric tracking remains sufficiently close to preserve accuracy.
合规信息
The ICL7135 family is an older precision analog measurement product; no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was identified for the exact ordering code. AEC-Q100 is not applicable to this general-purpose industrial A/D converter.