INA105AM-BB - Unity-Gain Differential Amplifier | Texas Instruments
料号: INA105AM-BB ✓ 量产中INA105AM-BB 概述
A differential amplifier is an amplifier IC that subtracts a signal applied to its inverting input from a signal applied to its non-inverting input. This function forms the foundation of instrumentation, current-shunt, bridge-sensor, and precision analog measurement circuits. The INA105 belongs to the broader operational-amplifier and signal-conditioning hierarchy, where accurate resistor ratios and common-mode rejection are essential for preserving small differential signals in the presence of much larger common-mode voltages.
The integrated resistor network eliminates the need to match and trim four external precision resistors. According to the manufacturer datasheet, the network is laser trimmed for accurate gain and high common-mode rejection. This integration simplifies the analog signal chain and reduces component-count and calibration requirements. The INA105 family is available in 8-pin plastic DIP, SOIC, and TO-99 metal packages, with INA105AM-BB identifying the metal-can configuration.
The unity-gain architecture makes the device suitable when a system requires instrumentation-amplifier-style differential conversion without adjustable gain. Its 250 µV maximum offset specification limits the output error caused by input mismatch. Because the INA105 is a dedicated precision difference amplifier rather than a general-purpose op-amp configured with external resistors, it can provide a more repeatable gain relationship in instrumentation applications.
Typical uses include bridge-transducer signal conditioning, differential receiver interfaces, shunt-amplifier signal paths, laboratory measurement systems, and industrial process-control inputs. In a bridge circuit, the two sensor outputs are applied to the differential inputs and the amplifier rejects common-mode voltage before converting the measurement to a single-ended result. This makes the INA105AM-BB suitable for sensors whose useful signal is much smaller than the voltage common to both input nodes.
Designers should preserve the polarity of the differential inputs, keep input and output return paths short, and provide adequate supply bypassing close to the device pins. Because the TO-99 package is a through-hole metal can, board-level thermal performance and socket or lead-frame compatibility should be checked against the enclosure and assembly process. Stable reference grounding is particularly important when the input difference is small relative to common-mode voltage.
This page combines the manufacturer functional description, package information, sourcing guidance, drop-in comparison, and practical implementation considerations. It highlights where the unity-gain INA105AM-BB differs from ordinary resistor-network differential amplifiers and from precision instrumentation-amplifier alternatives, helping engineers determine whether its fixed gain, integrated network, and TO-99-8 construction fit the target measurement circuit.
直接替换替代料: INA105AM-BB ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: INA105AM-BB (相同外形与封装尺寸) ——差异在于 Package.
INA105AM
✅ 直接替换联系询价
查看数据手册 →INA105AM-BS
✅ 直接替换📋 参考替代料(不在目录中)
AD549JHZ
✅ 直接替换📋 参考替代料(不在目录中)
INA105AM-BB 最大额定值与电气特性
| Amplifier Type | Precision unity-gain differential amplifier |
| Number of Circuits | 1 circuit |
| Nominal Gain | 1 V/V |
| Maximum Input Offset Voltage | 250 µV |
| 封装 | TO-99-8 metal can, 8 pins |
| 安装类型 | Through-hole |
| Integrated Resistor Network | Laser-trimmed metal-film network |
INA105AM-BB to-99-8 metal can, 8 pins 引脚配置指南
INA105AM-BB(to-99-8 metal can, 8 pins 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA105AM-BB.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA105AM-BB 适用于 6 应用s: Bridge Sensor Signal Conditioning, Precision Shunt Current Measurement, Differential Receiver Interface, Laboratory Instrumentation Front End, Industrial Process-Control Input, Medical and Diagnostic Signal Conditioning.
Bridge Sensor Signal Conditioning
The INA105AM-BB fits precision bridge-sensor front ends because its nominal gain of 1 V/V and integrated, laser-trimmed resistor network preserve the small differential voltage between two bridge nodes while rejecting their shared common-mode voltage. The device converts that differential result into a single-ended signal for a downstream converter or controller. Compared with a discrete difference amplifier, the internal matched network reduces resistor-ratio variation and calibration effort. Before finalizing the circuit, confirm the bridge excitation and common-mode voltage against the INA105 operating limits, and provide stable supply bypassing and a low-impedance reference return.
推荐
Precision Shunt Current Measurement
INA105AM-BB is appropriate for measuring the differential voltage generated across a current-sense shunt when the required gain is unity. Its 250 µV maximum input offset voltage defines the principal input-referred error term, while the integrated resistor network provides an accurate gain relationship. Place the amplifier close enough to the shunt to minimize pickup from the high-current conductor, maintain symmetry between the differential input traces, and connect the shunt return directly to the amplifier ground. The supply rails and common-mode limits must accommodate the shunt voltage under peak load.
推荐
Differential Receiver Interface
The INA105AM-BB can serve as the receiver stage for a balanced sensor, communication link, or analog front end whose signal is transmitted differentially. A unity-gain difference amplifier rejects common-mode voltage and delivers a single-ended output to the following analog stage, while the laser-trimmed on-chip network removes the need for four precisely matched external resistors. For reliable behavior, keep the two input paths similarly routed, avoid large ground-potential differences across the sensing points, and verify that signal and common-mode voltages remain within the manufacturer’s electrical limits.
推荐
Laboratory Instrumentation Front End
INA105AM-BB is useful in laboratory and test-instrument signal chains where a differential source must be referenced to an analog ground. Its fixed unity gain preserves the source amplitude while subtracting common-mode voltage, and the integrated laser-trimmed network gives repeatable conversion without manual resistor matching. In a precision bench instrument, use low-leakage input protection, clean analog grounding, and short traces between the source and amplifier. The 8-pin TO-99 metal package also provides a robust through-hole construction for instrument panels and higher-reliability assemblies when lead spacing matches the selected board layout.
推荐
Industrial Process-Control Input
INA105AM-BB can condition a low-level differential process signal before it enters an industrial controller. The unity-gain relationship is useful when the upstream sensor already produces a calibrated voltage, and the integrated resistor network limits gain error without a discrete trimming procedure. Designers should isolate the input from high-energy field wiring, establish one solid analog reference point, and keep the TO-99 device away from heat sources that could create temperature gradients across the board. Confirm the industrial temperature range and any required qualification status directly in the manufacturer ordering documentation.
推荐
Medical and Diagnostic Signal Conditioning
INA105AM-BB may be evaluated for low-level biomedical signal conditioning where a differential source must be converted to a single-ended signal with a fixed gain of 1 V/V. Its 250 µV maximum input offset voltage provides a defined input-referred error limit, while the internal trimmed network reduces gain uncertainty. A medical design must add the required patient protection, isolation, leakage-current analysis, and applicable regulatory controls; the amplifier package alone does not establish medical compliance. Keep patient-connected circuits physically separated from mains-derived power and verify the complete signal chain rather than treating the component as a certified medical device.
推荐
推荐产品汇总
工程参考数据: INA105AM-BB ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | INA105AM | INA105AM-BS | AD549JHZ |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| Package | TO-99-8 metal can | TO-99-8 metal can | CAN8 metal package | TO-99-8 |
| Amplifier Function | Precision unity-gain differential amplifier | Precision unity-gain differential amplifier | Operational amplifier, INA105 family | Precision differential amplifier |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole |
关键差异点
- Integrated precision gain network (对比 AD549JHZ)
- Defined input offset specification (对比 INA105AM-BS)
- Fixed-gain simplicity (对比 AD549JHZ)
设计说明
Use the manufacturer TO-99-8 package outline to establish the PCB hole pattern; do not derive spacing from a generic circular-can drawing. Keep the two differential inputs short, appropriately terminated, and routed away from switching nodes. Because the device provides a fixed difference function, ground offsets between the input reference and output reference directly affect accuracy. Connect the signal-source return and INA105 ground through a low-impedance path rather than allowing current from an adjacent relay, motor, or switching converter to flow in the reference conductor.
Bypass the supply pins close to the TO-99 package with a local high-frequency capacitor and place a bulk capacitor near the supply source. The exact capacitor values and stability requirements must be taken from the manufacturer application guidance because the available material does not state them. Check input and output voltage limits under startup, overload, and fault conditions. The precision offset specification does not prevent overload damage, so protect the input nodes when field wiring or switching transients can exceed the signal range.
Do not interchange the differential input polarity without recalculating the output sign, and avoid using a common ground symbol as a substitute for a carefully controlled analog return path. The integrated network makes the INA105 easier to apply than a discrete difference amplifier, but input common-mode voltage, supply range, and output swing remain important constraints. Confirm the exact INA105AM-BB ordering-code limits and TO-99 lead functions in the manufacturer datasheet before releasing a production layout.
Estimated power dissipation for the amplifier cannot be assigned from the available electrical data because supply voltage, quiescent current, output voltage, and load current are not stated. Calculate it from the final operating values using P = ((VIN - VOUT) × IOUT) + (VIN × IQ), then compare the resulting junction-temperature estimate with the device’s maximum rating. In a TO-99-8 package, thermal performance depends on the board copper, socket, airflow, and nearby heat sources, so the package outline alone is not an adequate thermal model.
合规信息
Compliance status is not explicitly stated in the manufacturer or distributor material reviewed for INA105AM-BB. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification documentation before regulatory use.