INA117AM-BB - ±200V Difference Amplifier | Texas Instruments
料号: INA117AM-BB ✓ 量产中INA117AM-BB 概述
A difference amplifier is an amplifier subtype that amplifies the voltage difference between two input signals while rejecting voltage common to both inputs. In the broader semiconductor hierarchy, it belongs to the amplifier family and, more specifically, to precision instrumentation and special-purpose amplifier categories. This topology is useful when a useful measurement is small but appears on top of a much larger common-mode voltage.
The INA117AM-BB’s principal characteristics are its unity-gain configuration, ±200V common-mode input range, integrated precision resistor network, and 8-pin metal-can construction. Its fixed unity gain makes circuit implementation predictable because the amplifier does not require an external feedback resistor to set the signal gain. The monolithic construction also keeps the matched resistor network and amplifier in one package, supporting consistent differential operation.
Technically, the device uses a precision op-amp core with an integrated thin-film resistor network to reject common-mode voltage and preserve the differential signal. Its input arrangement is intended for measuring small voltage differences in the presence of large common-mode potentials. This architecture is particularly valuable when conventional signal-chain components would be damaged by the common-mode voltage or unable to resolve the desired differential component.
Typical applications include high-voltage sensor-interface circuits, industrial process measurement, power-system monitoring, laboratory instrumentation, and data-acquisition front ends. In each case, the amplifier can isolate a small differential measurement from a substantially larger common-mode voltage. The TO-99-8 metal package also supports through-hole assembly, which can be advantageous for legacy instrument designs and hand-assembled prototypes.
When laying out a circuit around the INA117AM-BB, treat the input common-mode voltage, supply requirements, output range, and pin configuration as design constraints. Keep sensitive input and feedback connections short, provide appropriate bypassing near the supply pins, and verify the complete pinout against the manufacturer’s INA117 datasheet before assigning PCB tracks or socket connections.
This product page consolidates the verified INA117AM-BB package information, family-level technical characteristics, sourcing guidance, and practical design considerations. It also distinguishes the exact TO-99-8 part from related INA117 order codes whose package or qualification details must be checked before they are treated as replacements.
直接替换替代料: INA117AM-BB ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: INA117AM-BB (相同外形与封装尺寸) ——差异在于 Architecture, Common-Mode Input Voltage Range, Mounting Type.
INA117AM-BB 最大额定值与电气特性
| Product Type | Precision unity-gain difference amplifier |
| Manufacturer | Texas Instruments / Burr-Brown |
| Differential Input Signal | Small differential voltage |
| Common-Mode Input Voltage Range | Up to ±200V |
| Nominal Gain | 1 V/V |
| Integrated Network | Thin-film resistor network |
| Architecture | Single monolithic IC containing a precision op-amp and integrated thin-film resistor network |
| Channel Count | 1 channel |
| 封装 | TO-99-8 metal can |
| Package Pin Count | 8 pins |
| 安装类型 | Through-hole |
| Product Category | Linear - Amplifiers - Special Purpose |
| Application | Data acquisition |
| Product Status | Active |
INA117AM-BB 8 pins 引脚配置指南
INA117AM-BB(8 pins 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA117AM-BB.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA117AM-BB 适用于 6 应用s: High-Voltage Sensor Interface, Industrial Process Measurement, Laboratory Instrumentation, Power-System Monitoring, Data-Acquisition Front End, Legacy Instrument Repair.
High-Voltage Sensor Interface
The INA117AM-BB fits sensor-interface circuits where a small differential output must be measured while both input nodes carry a common-mode voltage as high as ±200V. According to the Texas Instruments INA117 datasheet, the unity-gain difference amplifier uses a precision op-amp and integrated thin-film resistor network to preserve the desired differential signal. Place the amplifier at the measurement front end, then use downstream circuitry for filtering, scaling, or conversion. Verify input limits and supply requirements in the manufacturer datasheet because the ±200V common-mode capability is not the device's supply-voltage rating.
推荐
Industrial Process Measurement
The INA117AM-BB is suitable for industrial process-measurement front ends where transducer signals can be small while the surrounding electrical system operates at a much higher potential. Its unity-gain architecture, described by Texas Instruments as a precision difference amplifier with an integrated thin-film resistor network, isolates the differential quantity without requiring an external gain-setting network. The amplifier can sit between protected input circuitry and a downstream ADC or instrumentation channel. Engineers should establish common-mode, supply, output, and thermal limits from the INA117 datasheet and account for the unique TO-99-8 lead arrangement in the control board.
推荐
Laboratory Instrumentation
The INA117AM-BB is appropriate for laboratory instruments that must measure small differential voltages referenced to a large common-mode potential. The Texas Instruments INA117 datasheet identifies the device as a precision unity-gain difference amplifier capable of handling common-mode signals up to ±200V, making it useful in bridge, feedback, and diagnostic measurements. Its fixed one-to-one gain simplifies front-end gain budgeting, while the monolithic thin-film network supports consistent operation. Use stable bypassing, short sensitive routes, and a verified metal-can pinout to preserve measurement integrity in a precision instrument.
推荐
Power-System Monitoring
The INA117AM-BB can support power-system monitoring circuits that detect small differential voltage changes across a high-potential node. Its ±200V common-mode capability allows the small signal of interest to be separated from a much larger common voltage, while unity gain provides a straightforward starting point for downstream conditioning. The result is useful in laboratory power-electronics analyzers, protection circuits, and diagnostic equipment. The design must maintain the device within its specified supply and absolute input limits, and the TO-99-8 package should be oriented according to the manufacturer pin-description diagram.
推荐
Data-Acquisition Front End
The INA117AM-BB is well suited to a high-voltage data-acquisition front end because it isolates a small differential measurement from common-mode signals extending to ±200V. According to Texas Instruments, the device combines a precision op-amp with an integrated thin-film resistor network and provides fixed unity gain, reducing the number of external components required to establish basic differential gain. The amplifier can feed a protected converter or instrumentation stage after suitable filtering and level verification. Check the complete operating limits, pinout, and thermal requirements in the manufacturer datasheet before using the legacy metal-can package in new acquisition hardware.
推荐
Legacy Instrument Repair
The INA117AM-BB is a practical replacement choice for repairing or maintaining legacy instruments designed around the Burr-Brown INA117 metal-can amplifier. The verified listing identifies the exact suffix in an 8-pin TO-99-8 through-hole package, which helps distinguish it from the family's plastic mini-DIP and SO-8 versions. According to Texas Instruments product information, the INA117 is a precision unity-gain difference amplifier with a common-mode range up to ±200V. Before replacement, compare the original schematic against the manufacturer pinout and verify device markings, temperature grade, and electrical requirements.
推荐
推荐产品汇总
工程参考数据: INA117AM-BB ——对比、设计指导和合规信息。
选型指南
Do not choose the INA117BM or INA117SM solely from visual order-code similarity. Package construction, pin arrangement, temperature grade, and marking must match the PCB and qualification requirements. No cross-brand drop-in replacement should be assumed because a different package or pin arrangement can make an otherwise similar difference amplifier unusable without board redesign. For a new design, confirm the INA117AM supply limits, output range, operating temperature, noise, and bias-current requirements against the manufacturer datasheet before releasing the schematic.
与替代料对比
| 参数 | 本产品 | INA117AM |
|---|---|---|
| Package | TO-99-8 metal can, 8 pins | TO-99-8, 8 pins |
| Brand | Texas Instruments / Burr-Brown | Texas Instruments |
| Product Type | Precision unity-gain difference amplifier | Precision unity-gain difference amplifier |
| Common-Mode Input Range | Up to ±200V | Up to ±200V |
| Gain | 1 V/V | 1 V/V |
| Internal Resistor Network | Integrated thin-film resistor network | Integrated thin-film resistor network |
| Mounting Type | Through-hole | Through-hole |
| Lifecycle Status | Active | Active |
关键差异点
- Very wide common-mode input capability for a unity-gain difference amplifier (对比 INA117AM)
- Exact legacy order-code traceability (对比 INA117AM)
- Integrated matched resistor network (对比 INA117AM)
设计说明
Assign the PCB footprint from the manufacturer's TO-99-8 pin-description diagram rather than a generic 8-pin DIP footprint. The metal-can package has a unique lead arrangement, so even a visually similar socket can produce incorrect supply, input, output, or reference connections. Confirm pin 1 orientation, the location of every no-connect position, and the mechanical body clearance before drilling holes or laying out the board.
Separate the ±200V common-mode input capability from the power-supply rating. Before energizing the circuit, verify the permitted supply voltages, absolute input limits, output range, and input/output relationship in the Texas Instruments INA117 datasheet. The common-mode range indicates which input potentials the amplifier can reject; it does not mean that ±200V can be applied to the supply pins.
Do not substitute INA117BM or INA117SM solely because their order codes are similar. The verified family information shows that INA117 variants include metal-can and surface-mount options with different packages, and a different package may require PCB changes or a different pin arrangement. Use INA117AM as the confirmed TO-99-8 drop-in candidate and validate all connections before installation.
Keep the two input paths symmetrical and minimize loop area around the amplifier pins. Route differential and reference connections away from switching-node copper and high-current return paths, and use the manufacturer's recommended bypassing arrangement. Because the device uses an integrated thin-film resistor network, asymmetric input routing can impair rejection of the common-mode signal even when the amplifier itself is operating correctly.
合规信息
The exact INA117AM-BB records do not provide product-specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations. AEC-Q100 is not applicable because this is a legacy TO-99-8 analog amplifier rather than an automotive-qualified device.