INA126UAG4 - 36V Precision Instrumentation Amplifier | TI
料号: INA126UAG4 ✓ 量产中INA126UAG4 概述
An instrumentation amplifier is a specialized amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal two-op-amp architecture provides accurate differential gain while rejecting common-mode interference. In the broader hierarchy, an instrumentation amplifier belongs to the amplifier IC category and provides a dedicated function for sensor front ends, where preserving signal integrity is more important than simply amplifying a single-ended voltage.
The INA126 family combines precision offset performance with very low power consumption. Its 175 µA per channel quiescent current supports battery-powered and portable equipment, while the 36 V supply range provides headroom for industrial measurement systems. The manufacturer identifies the device as a precision instrumentation amplifier for accurate, low-noise differential signal acquisition, with nominal gain set by an external resistor.
A two-op-amp architecture is used to establish the differential gain and reject common-mode voltage. An external gain-setting resistor lets the circuit adapt across a broad range of sensor sensitivities, while an accessible reference path can support bipolar or offset output systems. Because the INA126UAG4 is a single-channel device, systems requiring simultaneous differential measurements should use a dual-channel implementation or multiple matched devices.
Typical uses include bridge and strain-gauge signal conditioning, pressure and temperature sensor interfaces, current-shunt measurements, and low-power industrial data acquisition. The 200 kHz bandwidth identified for the INA126 family is suitable for many precision rather than high-speed signal chains. It is particularly useful when slow-changing sensor outputs must be measured accurately with limited supply current.
Designers should place input and gain-setting components close to the device, follow the manufacturer reference-circuit topology, and verify input common-mode and output-swing limits at the intended supply voltage. Input filtering should reject out-of-band interference without unnecessarily reducing bandwidth. Because gain is set externally, resistor tolerance and parasitic resistance directly affect gain accuracy and should be included in the system error budget.
This page combines manufacturer specifications, sourcing guidance, compatible-family comparisons, and practical design considerations to support faster component selection. It also identifies where application-specific verification is required before a precision measurement design is released for production.
直接替换替代料: INA126UAG4 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: INA126UAG4 (相同外形与封装尺寸) ——差异在于 Architecture, Package, Quiescent Current, Common-Mode Rejection Ratio, Device Type.
INA126U
✅ 直接替换联系询价
查看数据手册 →INA126UA
✅ 直接替换联系询价
查看数据手册 →INA126UAG4 最大额定值与电气特性
| Product Type | Precision instrumentation amplifier |
| Number of Channels | 1 channel |
| Architecture | Two-op-amp architecture |
| Maximum Supply Voltage | 36 V |
| Typical Dual-Supply Voltage | ±15 V |
| Minimum Supply Voltage | ±1.35 V |
| Maximum Supply Voltage from Comparison Listing | ±18 V |
| 静态电流 | 175 µA per channel |
| Input Offset Voltage | 250 µV |
| Bandwidth | 200 kHz |
| Minimum Operating Temperature | -40 °C |
| Temperature Grade | Industrial |
| 封装 | 8-pin SOIC |
| Package Width | 3.90 mm |
| Lead Form | Gull wing |
| Package Code | SOP |
| Package Shape | Rectangular |
| RoHS 状态 | Compliant |
| Supply Configuration | Single or dual supply |
| Input Signal | Differential |
| Gain Setting | External resistor |
INA126UAG4 rectangular 引脚配置指南
INA126UAG4(rectangular 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA126UAG4.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA126UAG4 适用于 6 应用s: Strain-Gauge Bridge Measurement, Pressure Sensor Signal Conditioning, Battery-Powered Instrument Front End, Current-Shunt Monitoring, Temperature Sensor Acquisition, Low-Level Data Acquisition.
Strain-Gauge Bridge Measurement
The INA126UAG4 fits strain-gauge and resistive-bridge front ends that require differential excitation sensing with limited operating current. Its precision instrumentation-amplifier architecture rejects common-mode voltage present across the bridge, while the 250 µV input offset specification helps preserve measurement resolution at low bridge output levels. The 175 µA typical quiescent current per channel is also advantageous for compact industrial transducers. Configure the external gain resistor according to the manufacturer reference circuit and keep the gain-setting connection compact to minimize parasitic resistance. The 200 kHz bandwidth is suitable for many quasi-static bridge signals without requiring a high-speed differential amplifier.
推荐
Pressure Sensor Signal Conditioning
The INA126UAG4 is appropriate for bridge-based pressure transmitters where a small differential signal must be amplified while supply and sensor excitation remain low power. Its differential input arrangement reduces sensitivity to common-mode variation, and the 250 µV offset rating supports accurate measurement near the lower end of the sensor output range. The device can operate from approximately ±1.35 V in suitable dual-supply applications or from a compatible single-supply arrangement when output headroom permits. Place the external gain resistor and input filtering close to the amplifier, and verify that the pressure-sensor excitation remains within the amplifier's input common-mode range.
推荐
Battery-Powered Instrument Front End
The INA126UAG4 supports portable and battery-powered measurement instruments where amplifier power can dominate available energy. Its 175 µA typical quiescent current per channel reduces the continuous burden of signal conditioning, while operation down to approximately ±1.35 V supports compact dual-rail systems. The 36 V maximum supply rating also permits use in higher-voltage instrumentation when the sensor interface requires more common-mode headroom. Choose external gain and filtering components with low leakage and account for their contribution to total system power. Confirm the output swing at the selected supply and light-load condition to avoid clipping sensor outputs near either rail.
推荐
Current-Shunt Monitoring
The INA126UAG4 can condition low-level voltage drops across a current-shunt when the measurement requires differential input, low quiescent current, and a reasonably wide supply range. A shunt signal is inherently differential, allowing common-mode supply or load voltage to be rejected more effectively than with a conventional single-ended amplifier. The 250 µV offset specification and external gain-setting arrangement are useful when resolving small shunt voltages. Install the shunt and amplifier input network so that Kelvin connections minimize copper-drop errors, and use filtering to suppress switching-node interference without degrading the intended measurement bandwidth.
推荐
Temperature Sensor Acquisition
The INA126UAG4 is well suited to low-level temperature sensor signals, particularly thermocouple, RTD, or resistive sensor networks implemented with a differential front end. Its low typical quiescent current preserves battery life in distributed monitoring equipment, while the precision offset rating supports sensor signals that occupy only a small portion of the available output range. The 200 kHz bandwidth accommodates many temperature signals that change slowly relative to the amplifier response. Apply proper cold-junction compensation for thermocouples and verify that sensor excitation, grounding, input filtering, and common-mode voltage are compatible with the INA126 operating limits.
推荐
Low-Level Data Acquisition
The INA126UAG4 supports laboratory and industrial data-acquisition channels that measure small differential voltages with modest bandwidth requirements. Its two-op-amp instrumentation-amplifier architecture provides a defined gain path and common-mode rejection, while 175 µA typical current per channel benefits multi-channel compact designs. The 200 kHz bandwidth is appropriate for many temperature, pressure, force, and slow-motion displacement sensors rather than high-rate waveform capture. Use consistent input filtering and reference arrangements across channels, and include the gain-setting resistor tolerance and input bias-current effects in the overall accuracy calculation.
推荐
推荐产品汇总
工程参考数据: INA126UAG4 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | INA126U | INA126UA | INA129U | INA128U |
|---|---|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Type | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier |
关键差异点
- Combines precision offset performance with micropower operation (对比 INA129U)
- Supports a broad 36 V maximum supply environment (对比 INA128U)
- Uses the established INA126 two-op-amp gain architecture (对比 INA126U)
设计说明
Verify the complete pin function, gain-setting method, input common-mode range, and output swing before treating a related INA order code as a replacement. The target uses an 8-pin SOIC package, but package equality alone does not prove electrical interchangeability. Compare the manufacturer gain equations because a changed gain relationship can alter both the selected resistor value and the resulting closed-loop accuracy.
Place the external gain resistor and input compensation or filter components close to their corresponding INA126UAG4 pins. Keep differential input traces short, matched where practical, and away from switching-node and high-current return paths. Connect the input return near the signal-source ground to prevent ground-potential differences from entering the differential input.
Choose input filtering from the required signal bandwidth rather than adding arbitrary capacitance. Excess capacitance can alter stability, phase margin, and the usable bandwidth of the closed-loop amplifier. For low-frequency sensors, place filtering mainly for antialiasing and conducted-noise control; for faster signals, use the manufacturer's gain-versus-frequency guidance to avoid degrading response.
Check output headroom under the lightest expected load. A low quiescent current does not guarantee accurate operation if the required output voltage approaches either supply rail. Also include the external gain resistor and input network when comparing total standby power, because their values can determine both current draw and signal accuracy.
合规信息
RoHS compliance is identified by the product listing. The INA126UAG4 is an industrial-temperature precision instrumentation amplifier rather than an automotive-qualified device. No additional compliance claims are made.