INA129SHKQ - ±18V Precision Instrumentation Amplifier | TI
料号: INA129SHKQ ✓ 量产中INA129SHKQ 概述
An instrumentation amplifier is a specialized differential-input amplifier optimized for measuring small signals superimposed on large common-mode voltages. Its internal gain-setting architecture, high input impedance, and common-mode rejection distinguish it from general-purpose operational amplifiers. The INA129 belongs to the instrumentation-amplifier hierarchy within signal-chain ICs and analog measurement systems, where it converts low-level sensor outputs into a robust differential signal suitable for analog-to-digital conversion.
Key characteristics include 25 µV typical offset voltage, 50 nA typical input bias current, and 95 dB typical common-mode rejection. The gain equation is compatible with the AD620, with a single external resistor setting gain from 1 to 10000. Input protection extends to ±40 V, while the wide ±18 V supply range supports industrial, military, and high-voltage measurement systems. A low 2 mA typical quiescent current also limits power consumption in portable or distributed instrumentation.
Internally, the INA129 combines a precision input stage, difference amplifier, gain-setting network, and laser-trimmed offset compensation. Its common-mode rejection of 93 dB at gains of 100 or higher helps suppress supply noise and unwanted common-mode signals. The 1.3 MHz bandwidth supports moderately fast measurements while the 4 V/µs slew rate preserves large-signal response through the output stage.
Typical uses include bridge-transducer amplification, current-shunt measurement, precision pressure sensing, ECG instrumentation, and high-voltage sensor interfaces. The ceramic SOIC package supports controlled thermal and environmental performance where an extended -55°C to 210°C operating range is required. Applications requiring only industrial-temperature grades should evaluate lower-cost standard-package variants before releasing a production design.
PCB design should use short differential input traces, solid grounding around the gain resistor, and decoupling close to the supply pins. Input filtering must preserve the sensor bandwidth while limiting high-frequency noise. Because the INA129SHKQ is a high-temperature military-grade option, designers should verify thermal margins, solder assembly constraints, sourcing requirements, and all operating conditions against the Texas Instruments INA129-HT documentation.
This product overview combines the device function, electrical limits, environmental ratings, replacement considerations, and application-level guidance into a practical engineering reference for instrumentation-amplifier design.
直接替换替代料: INA129SHKQ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: INA129SHKQ (相同外形与封装尺寸) ——差异在于 Input Bias Current, Mounting Type, Operating Temperature Range, Package.
INA129UA
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →INA128SHKQ
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
INA129SHKQ 最大额定值与电气特性
| Product Type | Precision, low-power instrumentation amplifier |
| Number of Channels | 1 channel |
| Closed-Loop Gain | 10 V/V |
| Programmable Gain Range | 1 to 10000 V/V |
| Gain-Bandwidth Product | 1.3 MHz |
| Slew Rate | 4 V/µs |
| 电源电压 | ±18 V |
| 工作温度范围 | -55°C to 210°C |
| Offset Voltage | 25 µV typical |
| Input Bias Current | 50 nA typical |
| Common-Mode Rejection | 95 dB typical |
| Common-Mode Rejection at Gain ≥100 | 93 dB |
| Input Protection Range | ±40 V |
| 静态电流 | 2 mA typical |
| 封装 | 8-pin ceramic SOIC, 0.220-inch body width |
| Terminal Count | 8 terminals |
| 安装类型 | Gull-wing surface mount |
| Temperature Grade | Military high-temperature grade |
| Gain Equation Compatibility | Compatible with AD620 gain equation |
INA129SHKQ 8-pin ceramic soic, 0.220-inch body width 引脚配置指南
INA129SHKQ(8-pin ceramic soic, 0.220-inch body width 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA129SHKQ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA129SHKQ 适用于 6 应用s: Bridge Transducer Amplification, High-Side Current-Shunt Measurement, Precision Pressure Sensor Interface, High-Temperature Process Measurement, Medical and Biopotential Front End, Aerospace Sensor and Telemetry Interface.
Bridge Transducer Amplification
The INA129SHKQ suits Wheatstone bridge sensing because its 95 dB typical common-mode rejection reduces the influence of large common-mode excitation while the 25 µV typical offset preserves small differential outputs. A single resistor establishes the programmed gain, and the AD620-compatible equation simplifies gain calculation. Designers should balance the two input paths, place the gain resistor close to the device, and verify output swing across the bridge range. The -55°C to 210°C rating is valuable where the bridge or transmitter operates in a high-temperature industrial or aerospace environment.
High-Side Current-Shunt Measurement
For current-shunt monitoring, the INA129SHKQ amplifies a small differential voltage while rejecting voltage common to both shunt terminals. Its 50 nA typical input bias current limits the error introduced by high-impedance sensor wiring, while the ±40 V protected-input range adds tolerance for transients. The 4 V/µs slew rate permits response to faster current changes than the 1.3 MHz gain-bandwidth product alone would suggest. Layout must minimize differential-loop area and keep return-current paths away from the input traces.
Precision Pressure Sensor Interface
The INA129SHKQ can condition a low-level differential pressure-sensor output before an external ADC. Its 10 V/V closed-loop gain amplifies millivolt-scale signals, while 95 dB typical common-mode rejection helps isolate the measurement from sensor excitation noise and ground offsets. The 25 µV typical offset is meaningful relative to small bridge outputs, and the 2 mA typical quiescent current supports power-conscious instrumentation. Engineers should calculate the actual closed-loop bandwidth at the selected gain and include anti-alias filtering ahead of the converter.
High-Temperature Process Measurement
The INA129SHKQ is appropriate for process-control channels that operate from -55°C to 210°C because that extended range is a defining feature of the ordering option. The 1.3 MHz gain-bandwidth product supports sensor signals from moderately fast processes, while the ceramic-SOIC package matches high-reliability assembly requirements. At elevated temperature, verify offset behavior, input bias current, resistor drift, and thermal gradients across the board. Gain-setting components should use suitable temperature coefficients so they do not negate the amplifier's low offset.
Medical and Biopotential Front End
The INA129SHKQ can serve as the differential input stage of a biopotential or diagnostic-signal amplifier when the system operates across the device's extended temperature range. The instrumentation-amplifier architecture provides high input impedance and 95 dB typical common-mode rejection, helping reject mains-coupled common-mode interference before further gain stages. Its 4 V/µs slew rate supports higher-frequency physiological waveforms within the 1.3 MHz bandwidth limit. Patient-safety, isolation, dielectric requirements, and applicable medical standards must be evaluated separately from electrical performance.
Aerospace Sensor and Telemetry Interface
The INA129SHKQ suits aerospace sensor interfaces where extended-temperature operation and a protected differential input are valuable. Its 95 dB typical common-mode rejection improves signal integrity when the sensor returns share ground with switching or high-energy systems, and the 25 µV typical offset supports precision telemetry channels. The 50 nA typical input bias current minimizes sensor-loading error. System integrators should still verify vibration packaging, solder-joint reliability, radiation requirements, and qualification documentation separately from the device's electrical ratings.
工程参考数据: INA129SHKQ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | INA129UA | INA128SHKQ |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin ceramic SOIC | 8-pin SOIC | 8-pin ceramic SOIC |
| Product Type | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier |
| Gain Equation | AD620-compatible | AD620-compatible | INA128 industry-standard equation |
关键差异点
- Extended high-temperature operating range (对比 INA129UA)
- AD620-compatible gain calculation (对比 INA128SHKQ)
- Precision input-stage characteristics (对比 INA129UA)
设计说明
Route the two input signals as a close-coupled differential pair and keep the INA129SHKQ gain resistor close to its package pins. Place input filtering symmetrically to avoid converting common-mode noise into differential error. Connect a solid ground reference beneath the device and keep switching-converter and digital return currents away from the input and feedback nodes.
Do not assume that an AD620-compatible gain equation makes every INA12x device interchangeable. INA128 and INA129 use different external resistor equations, so changing family requires recalculating the gain-setting resistor. Also verify the reference-pin voltage, output-swing limits, supply polarity, and all pin names in the device pin-description table before fabrication.
Use the -55°C to 210°C rating as an environmental operating limit, not a thermal design target. At the upper temperature extreme, check offset drift, bias-current behavior, resistor tolerances and temperature coefficients, and board gradients. The 2 mA typical quiescent current is generally modest, but nearby regulators and high-impedance source nodes still require normal thermal and layout analysis.
Calculate the usable closed-loop bandwidth at the programmed gain rather than treating the 1.3 MHz gain-bandwidth product as a constant signal bandwidth. At a gain of 10, the approximate gain-bandwidth relationship indicates substantially less bandwidth than the amplifier's small-signal gain-bandwidth product. Place anti-alias filters before the amplifier where excessive bandwidth could increase noise or move the signal toward the ADC sampling spectrum.
合规信息
The INA129SHKQ is identified as a military high-temperature instrumentation amplifier. Specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the current manufacturer product documentation or project-specific procurement records.