INA141UA/2K5 - Precision 10/100 Instrumentation Amplifier | TI
料号: INA141UA/2K5 ✓ 量产中INA141UA/2K5 概述
An instrumentation amplifier is a specialized analog amplifier designed to amplify small differential signals while rejecting common-mode interference. The INA141 belongs to the broader hierarchy of instrumentation amplifiers, differential amplifiers, analog amplifiers, and integrated circuits. Its internal three-op-amp architecture and current-feedback input stage provide accurate gain control and useful bandwidth when operating at the higher 100 V/V gain setting. The device is commonly used where sensor outputs are small and the surrounding environment contains significant common-mode voltage.
The main electrical features include low offset voltage of 50 µV maximum, low offset drift of 0.5 µV/°C maximum, low input bias current of 5 nA maximum, and a common-mode rejection ratio of 117 dB minimum. The inputs are protected against ±40 V signals, while the wide ±18 V supply capability supports higher-level analog systems. These characteristics make the amplifier suitable for bridge sensors, biomedical instrumentation, industrial measurement, and precision current sensing.
The INA141 uses a three-op-amp instrumentation-amplifier architecture. Its gain can be selected at 10 V/V or 100 V/V rather than continuously adjusted, which simplifies calibration and reduces the number of external precision resistors required. Current-feedback input circuitry maintains 200 kHz bandwidth at gain 100, a useful result for applications that need faster settling than a conventional fixed-gain amplifier can provide. Input protection is important in industrial systems because transients can appear on sensor wiring before external protection networks fully respond.
Typical applications include Wheatstone bridge amplification, pressure and load-cell signal conditioning, isolated or battery-powered measurement systems, and low-level differential sensor interfaces. The ±40 V input protection can improve robustness when a sensor line is exposed to accidental overload, while the 117 dB minimum common-mode rejection helps preserve accuracy when the signal is small relative to the common-mode voltage. The 8-pin SOIC package also supports compact, surface-mount PCB layouts.
Designers should pay close attention to supply headroom, input common-mode range, output swing, and grounding when selecting the gain setting. Decoupling capacitors should be placed close to the supply pins, and the input and reference pins should be routed away from noisy switching nodes. The gain setting should be selected only after checking the available output swing and the sensor’s full-scale differential range.
This page combines the Texas Instruments product information, verified distributor availability information, same-package replacement references, and practical engineering guidance to support component selection, PCB design, and sourcing. It also distinguishes the exact INA141UA/2K5 ordering code from related INA141 variants so engineers can evaluate fit without treating every related amplifier as an exact replacement.
直接替换替代料: INA141UA/2K5 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: INA141UA/2K5 (相同外形与封装尺寸) ——差异在于 Package, Supply Voltage Range, Amplifier Type, Architecture, Gain.
INA141UA
✅ 直接替换联系询价
查看数据手册 →INA141U
✅ 直接替换联系询价
查看数据手册 →INA141UA/2K5G4
✅ 直接替换📋 参考替代料(不在目录中)
INA141UA/2K5E4
✅ 直接替换📋 参考替代料(不在目录中)
INA141UA/2K5 最大额定值与电气特性
| Product Type | Precision instrumentation amplifier |
| Number of Channels | 1 channel |
| Gain | 10 V/V or 100 V/V |
| Supply Voltage Range | ±2.25 V to ±18 V |
| Maximum Supply Voltage | 36 V total |
| Input Offset Voltage | 50 µV maximum |
| Input Offset Voltage Drift | 0.5 µV/°C maximum |
| Input Bias Current | 5 nA maximum |
| Common-Mode Rejection Ratio | 117 dB minimum |
| Input Protection Range | ±40 V |
| Bandwidth at Gain 100 | 200 kHz |
| 工作温度范围 | -40°C to +85°C |
| 封装 | 8-pin SOIC (D) |
| 安装类型 | Surface mount |
| Architecture | Three-op-amp instrumentation amplifier with current-feedback input circuitry |
INA141UA/2K5 8-pin soic (d) 引脚配置指南
INA141UA/2K5(8-pin soic (d) 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA141UA/2K5.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA141UA/2K5 适用于 6 应用s: Load Cell and Pressure Sensor Amplification, Industrial Current Sensing, Medical and Biopotential Signal Conditioning, Precision Bridge and Strain Measurement, Portable and Battery-Powered Instrumentation, Data Acquisition and Test Equipment.
Load Cell and Pressure Sensor Amplification
The INA141UA/2K5 fits Wheatstone-bridge front ends that produce millivolt-level differential signals while rejecting a much larger common-mode voltage. Its selectable 10 V/V and 100 V/V gains provide useful scaling without a continuously adjustable gain network, while 50 µV maximum offset voltage limits signal error near the measurement floor. The 117 dB minimum common-mode rejection is particularly useful when bridge excitation and ground gradients dominate the differential output. In implementation, place the amplifier close to the bridge, balance the two input routes, and verify that the selected gain keeps the full bridge output inside the device output-swing range.
推荐
Industrial Current Sensing
The INA141UA/2K5 is appropriate for amplifying the small differential voltage produced by a current shunt or current-transformer output. Gain 10 can preserve headroom for moderate signals, while gain 100 increases sensitivity when the shunt voltage is small. Its low 5 nA maximum input bias current helps avoid measurement error with high-impedance sensing networks, and the current-feedback input stage supports 200 kHz bandwidth at gain 100 for faster transient capture. Keep the shunt or sensor return close to the amplifier ground reference, use matched input traces, and avoid sharing those routes with switching power nodes.
推荐
Medical and Biopotential Signal Conditioning
The INA141UA/2K5 can condition low-amplitude differential signals in biomedical instrumentation when electrode or sensor signals require common-mode suppression. Its selectable gains support two measurement ranges, and its 117 dB minimum common-mode rejection helps isolate small differential components from body-coupled or equipment-induced common-mode voltage. The ±40 V input protection rating is useful for robust sensor interfaces, but protection-state behavior and applicable medical system requirements must be evaluated carefully. Use guarded grounding, isolated power where required, and carefully isolated routing so the analog input network does not become an unintended current path.
推荐
Precision Bridge and Strain Measurement
The INA141UA/2K5 supports strain-gauge and resistive-bridge systems where excitation produces a small differential signal around a common-mode voltage. Gain 100 increases the signal level for ADC capture, while the 200 kHz bandwidth supports measurements faster than static weighing alone. Low offset voltage of 50 µV maximum and low drift of 0.5 µV/°C maximum help maintain accuracy across temperature changes. For best results, use stable excitation, low-noise reference grounding, matched input routing, and calibration that covers the selected gain range and expected sensor temperature range.
推荐
Portable and Battery-Powered Instrumentation
The INA141UA/2K5 suits portable test and measurement equipment that must amplify differential sensor signals while operating from limited supply voltage. Its compact 8-pin SOIC package simplifies board integration, and the architecture supports gains of 10 V/V and 100 V/V for matching different sensor ranges. Operation begins at ±2.25 V, although usable signal range still depends on output swing, common-mode limits, and the selected gain. Low-power design should account for both the amplifier's own consumption and the sensor excitation current, while using local bypass capacitance to keep supply noise from reducing common-mode rejection.
推荐
Data Acquisition and Test Equipment
The INA141UA/2K5 is useful in bench instruments and data-acquisition systems that must amplify small differential sources before conversion by an ADC. Gain 10 provides moderate attenuation of the source signal, while gain 100 supports high-resolution measurements with small full-scale outputs. The 200 kHz bandwidth at gain 100 accommodates many higher-speed acquisition tasks, and the single-channel SOIC package leaves board space for additional channels. Designers should account for ADC input range, acquisition time, settling behavior, grounding, and connector protection rather than treating the amplifier as a complete front end.
推荐
推荐产品汇总
工程参考数据: INA141UA/2K5 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | INA141UA | INA141U | INA141UA/2K5G4 | INA141UA/2K5E4 | INA131AP |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) |
| Product Family | INA141 | INA141 | INA141 | INA141 | INA141 | INA131 |
| Number of Channels | 1 channel | 1 channel | 1 channel | 1 channel | 1 channel | 1 channel |
| Gain | 10 V/V or 100 V/V | 10 V/V or 100 V/V | 10 V/V minimum | 10 V/V or 100 V/V family configuration | 10 V/V or 100 V/V family configuration | 10 V/V minimum |
关键差异点
- Exact active INA141UA/2K5 ordering configuration (对比 INA141UA/2K5G4)
- 200 kHz bandwidth at the maximum 100 V/V gain (对比 INA131AP)
- Minimum common-mode rejection of 117 dB (对比 INA141UA)
- Input protection to ±40 V (对比 INA141U)
设计说明
Place the INA141UA/2K5 close to the sensor or bridge output, and route the two differential inputs as a short, closely spaced pair. Keep the reference connection and analog ground return away from switching-converter and digital-clock nodes. Place supply bypass capacitors directly beside the relevant SOIC supply pins, with a short ground return. Symmetrical routing is important because mismatched input impedances and trace leakage can reduce the practical common-mode rejection achieved in a finished board.
Do not select a gain solely from the sensor's nominal sensitivity. First confirm the full differential signal range, common-mode voltage, output swing, supply voltage, and allowed error. The INA141UA/2K5 supports 10 V/V and 100 V/V, but either setting can clip if the amplifier lacks sufficient output headroom. Also verify the exact gain-code behavior for the ordered suffix instead of assuming that every related INA141 ordering code uses identical gain-selection logic.
For the fastest measurements, use very low source impedances and keep input-node capacitance balanced. The 200 kHz bandwidth at gain 100 supports useful acquisition speed, but the complete signal chain must also settle within the ADC sample window. Use a suitable low-impedance reference, maintain return paths continuous during cable or connector transitions, and evaluate gain error and settling with the actual sensor rather than relying only on the amplifier's headline bandwidth.
Estimate power dissipation using the actual positive and negative supply currents, supply voltage, and output operating point across the required -40°C to +85°C ambient range. The 8-pin SOIC package has limited copper area compared with exposed-pad options, so airflow, board copper, and nearby heat sources matter. Do not infer thermal margin from the low-power description alone; use the manufacturer power dissipation and thermal resistance tables for the final worst-case assessment.
合规信息
A related Abacus Technologies catalog entry identifies INA141UA/2K5E4 as EU RoHS compliant, REACH compliant, and DRC Conflict Free. Exact suffix-level declarations for INA141UA/2K5 were not established, so the individual fields remain unknown.